• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Variable Frequency Drive Field Installation
Variable Frequency Drive Field Installation

KL3518001806
KL3518001806

... actually discuss or evaluate the performance of induction motor drives associated with three-phase multilevel inverter. This paper presents a comparison study of symmetrical and asymmetrical for a cascaded H-bridge multilevel using flexible control technique and also direct torque control (DTC) for ...
HV industrial network design
HV industrial network design

... voltage drops during starting); ■ power supply to arc furnaces, the arc often being unstable, which causes brief but repeated unbalanced voltage drops (resulting in flicker), and can create harmonics; ■ power supply to high capacity electronic devices (rectifiers, thyristors, etc.) which create majo ...
Specification for three phase AUMATIC electric actuators - Auma-USA
Specification for three phase AUMATIC electric actuators - Auma-USA

- Interroll
- Interroll

... conveyor system. Any other use is considered inappropriate. Any modifications that affect the safety of the product are not permitted. The DriveControl 20/54 may only be operated within the defined operating limits. Deviating applications require the approval of Interroll. ...
power from magnetism: over-unity motor design
power from magnetism: over-unity motor design

... mechanical work. Finally one ensures that no further magnetic energy is fed into the pole gaps during their separation. There is no reference to a magnet in this sequence of events. So let us now introduce a magnet and regard the rotor poles as being those of a permanent magnet, with the stator pole ...
Digital Multimeter Instruction Manual MS6574
Digital Multimeter Instruction Manual MS6574

Document
Document

... Q. CSX soft starters control only two phases, leaving one phase connected to the supply. Does this mean an additional line contactor must be employed in a circuit breaker/CSX motor branch circuit ? A. No. Use of a two phase soft starter does not require an additional line contactor as compared with ...
5 HP – 30 HP Single-Phase to Three
5 HP – 30 HP Single-Phase to Three

... digital phase converter for operating three-phase electrical equipment from a singlephase source. The converter shall deliver balanced, sine-wave voltages with high efficiency, electronic power factor correction and high momentary overload currents for starting motors. Protection from under-voltage ...
Master-slave switchover application
Master-slave switchover application

The final step of designing and implementing a reactive system is to
The final step of designing and implementing a reactive system is to

lecture notes
lecture notes

... bulky, rigid and have a heavy mass. Hence they cannot respond rapidly to measurements of dynamic and transient conditions. Besides, many of them are the potential sources of noise. On the other hand, electrical instruments are very rapid in response. However, their operating mechanism normally depen ...
Optimal design and control of electrical machines for more efficient
Optimal design and control of electrical machines for more efficient

(DEE 411)
(DEE 411)

... Two independent single-phase semi-converters are supplying the armature and field circuits of the separately excited dc motor for controlling its speed. The firing angle of the converter supplying the field, adjusted such that maximum field current flows. The machine parameters are : armature resist ...
vacon 10 complete user manual ac drives
vacon 10 complete user manual ac drives

... EN61800-3 defines the division of frequency converters into four classes according to the level of electromagnetic disturbances emitted, the requirements of a power system network and the installation environment (see below). The EMC class of each product is defined in the type designation code. Cat ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676

... A Switched Reluctance Motor (SRM) is a rotating electric machine where both stator and rotor have salient poles as shown in Fig. 1. The stator winding comprises a set of coils, each of which is wound on a pole. SRM’s differ in the number of phases wound on the stator. Each of them has a certain numb ...
this manual (in PDF format) refer to product model and version that
this manual (in PDF format) refer to product model and version that

Research Setup for Special Purpose Permanent Magnet
Research Setup for Special Purpose Permanent Magnet

installation considerations electric motor
installation considerations electric motor

... Lead Length. Lead length is the length of the conductors (motor leads) between the electric motor drive and the motor. The motor leads T1, T2, and T3 have a lineto-line capacitance and a line-to-ground capacitance. Capacitance increases the magnitude of the voltage spikes at the motor terminals. The ...
relay problems
relay problems

... current decreases, causing the contacts to open and drop the start winding out of the circuit. This normally occurs at approximately 75% of full running speed. A push-on type current relay is used on small fractionalhorsepower, hermetic refrigeration compressors. The relay is pushed onto the start a ...
Single layer winding and Double layer winding SINGLE LAYER
Single layer winding and Double layer winding SINGLE LAYER

...  This is obtained by having similar pole phase groups (a pole phase group is defined as a group of coils of a phase under one pole) and arranging the groups to have an effective displacement of y =2/m electrical radians in space. ...
A Study of De-Excitation after Abrupt 3
A Study of De-Excitation after Abrupt 3

... during that period. It is a constant 0.803H in first section, then decreases in saturation section of N-LC, and returns to 0.803H after 3-phase short circuit. The time for voltage building up is long owing to Tdo’=10.1” of 700Mw generator. In order to be more clearly, other pictures in Fig.6 only sh ...
MDUG-CM2/14501E-01
MDUG-CM2/14501E-01

ICS 16-2001
ICS 16-2001

AN1946
AN1946

... Permanent Magnet Brushless DC Motors are replacing brush motors in numerous applications as they offer significant energy efficiency improvements, lower acoustic noise and better reliability to name a few advantages. To be driven and controlled properly, 3-phase Permanent Magnet Brushless motors req ...
< 1 ... 32 33 34 35 36 37 38 39 40 ... 213 >

Brushed DC electric motor



A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report