• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SyNCHRONOUS MOTOR PROTECTION SySTEM
SyNCHRONOUS MOTOR PROTECTION SySTEM

Considering Instantaneous Voltage Drop Versus Sustained Voltage
Considering Instantaneous Voltage Drop Versus Sustained Voltage

Voltage Transducer LV 100-100 VPN = 100 V
Voltage Transducer LV 100-100 VPN = 100 V

... This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. ...
Voltage Transducer LV 100-600 VPN = 600 V
Voltage Transducer LV 100-600 VPN = 600 V

Induction Motor and Self-Excited Induction Generator
Induction Motor and Self-Excited Induction Generator

... The cage motor is cheap, robust, and practically maintenance free due to the absence of moving contacts. It can operate in extremely adverse environments, for example contaminated and explosive atmospheres and even in submersible equipment. The major disadvantages of the cage motor are its low start ...
Use of Motor Protection Circuit Breakers with Variable
Use of Motor Protection Circuit Breakers with Variable

... the carrier frequency of the VFD should be selected as low as possible and must not exceed 4 kHz to avoid overheating. This is in agreement with recommendations given for line terminators and filters. The actual motor operational current of the MPCBs (140M) should be as close as possible to the low ...
Manual - Robot Marketplace
Manual - Robot Marketplace

... Instead of a pot the input may be fed from a variable ...
maxon DC motor and maxon EC motor Key information
maxon DC motor and maxon EC motor Key information

... to the wound stator teeth they have a higher terminal inductance than motors with an ironless winding. As a result at higher speed, the current cannot develop fully during the correspondingly short commutation intervals. Therefore, the apparent torque produced is lower. Current is also fed back into ...
Compressor starting current too high?
Compressor starting current too high?

MC3479 PCB Description - ME210-CKA
MC3479 PCB Description - ME210-CKA

... Motorola’s MC3479 provides logic and power drive stages for controlling 2-phase bipolar stepper motors. It has output stages capable of supplying up to 350mA/phase. The maximum current supplied to a motor is internally limited by the MC3479, and this current limit may be adjusted by the selection of ...
2015 Regulated current with UserSubroutine using groovy language YS CN67
2015 Regulated current with UserSubroutine using groovy language YS CN67

... Without the user subroutine, currents are leading to very high level of saturations, which can be seen when we check the flux density (see figure 4). ...
Vasii 1
Vasii 1

... Abstract The electric gear-boxes have a continue variation of conduction ratio and are composed from electric generator and one or more electric engines. The mechanical power produced by the engine with internal burning is transform in electric energy by the electric generator and this will be trans ...
1- Harmonic Sources from Commercial Loads
1- Harmonic Sources from Commercial Loads

... ransistors for this purpose the VSI PWM drive offers the best energy efficiency for applications over a wide speed range for drives up through at least 500 hp. Another advantage of PWM drives is that, unlike other types of drives, it is not necessary to vary rectifier output voltage to control motor ...
owner`s manual - Advantage Manufacturing
owner`s manual - Advantage Manufacturing

... EVOLUTION ASSEMBLY INSTRUCTIONS (Including Impeller and Seal Replacement) WARNING: ALWAYS DISCONNECT THE ELECTRICAL POWER FROM THE PUMP MOTOR BEFORE ...
owner`s manual - Advantage Manufacturing
owner`s manual - Advantage Manufacturing

Lab Manual - Lakehead University
Lab Manual - Lakehead University

... Failure to perform one or more lab exercises results in a grade of "F" for the course. When a student misses a lab exercise for whatever reason he/she must notify the instructor as soon as possible. If the reasons given for the absence are satisfactory to the instructor, a make-up opportunity may be ...
Daily Constant PV Output Power Supplying AC Pumps
Daily Constant PV Output Power Supplying AC Pumps

Mark IIxg Electric Fire Pump Controllers
Mark IIxg Electric Fire Pump Controllers

... Starting (Closed Circuit Transition) These Controllers are available assembled with power transfer switches for use with an emergency generator set or second power source. ...
Lecture_10
Lecture_10

... An electric motor turns because there is a torque on it due to the current. We would expect the motor to accelerate unless there is some sort of drag torque. That drag torque exists, and is due to the induced emf, called a back emf. ...
maxon DC motor and maxon EC motor Key
maxon DC motor and maxon EC motor Key

... current, at which the maximum winding temperature is attained under standard conditions (25°C ambient temperature, no heat dissipation via the flange, free air circulation). Higher motor currents cause excessive winding temperatures. The nominal current is selected so that it corresponds to this max ...
TMdrive-XL80 Data Sheet
TMdrive-XL80 Data Sheet

... transformer, the TMdrive-XL80 has 24-pulse rectification, which reduces the harmonic voltage distortion on the power source and protects the other equipment in the plant. The harmonic current content measured in an actual load test is compared with IEEE-519 in the chart opposite, showing it more tha ...
Lecture 17 - Purdue Physics
Lecture 17 - Purdue Physics

... Lenz’s Law “The induced current will create a magnetic field that opposes the change in flux.” The clockwise current creates a field pointing down in the middle of the loop. If the current is clockwise, then it also creates a magnetic field pointing down. Therefore, ...
code issues Motor Design Letters and By James Stallcup Sr., NEC/OSHA Consultant
code issues Motor Design Letters and By James Stallcup Sr., NEC/OSHA Consultant

... for motor windings and components when motors are starting, running, and driving loads. Motor windings are protected by overcurrent protection devices that are selected according to the type used, based upon the amount of starting current required. Overcurrent protection devices are sized by percent ...
Compact V/f Control Drive YASKAWA AC Drive
Compact V/f Control Drive YASKAWA AC Drive

... cost low. If even more braking torque is needed, an additional braking resistor can be connected to the built-in braking transistor. Swing PWM minimizes noise and leakage current, quieting disturbing motor noise. ...
System Identification and Integration Design of an Air/Electric Motor
System Identification and Integration Design of an Air/Electric Motor

... machinery, or other applications where starts and stops are made quickly and accurately. Servo motors have lightweight, low-inertia armatures that respond quickly to excitation-voltage changes. A King Right 24 V DC servo motor is selected, which is rated at power of 700 W, a largest torque of 2 Nm, ...
< 1 ... 131 132 133 134 135 136 137 138 139 ... 213 >

Brushed DC electric motor



A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report