• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Continued… - Pcpolytechnic
Continued… - Pcpolytechnic

PP.AFD.07
PP.AFD.07

... Inoise May be Common or Differential Mode ...
EPOS4 50/15 Hardware Reference
EPOS4 50/15 Hardware Reference

Manual-HC4-7-english.. - Powertech Engines Inc
Manual-HC4-7-english.. - Powertech Engines Inc

... irrespective of main stator loading and provides high motor starting capability as well as immunity to waveform distortion on the main stator output created by non linear loads, e.g. thyristor controlled dc motor. The MX341 AVR senses average voltage on two phases ensuring close regulation. In addit ...
ZAPI ACE-2 manual
ZAPI ACE-2 manual

... should be in the 1.5 mA to 30 mA range. Faults can occur if it is outside this range. The standard connection for the potentiometer is the one in the Left side of next figure (potentiometer on one end at rest) in combination with a couple of Travel demand switches. On request it is also possible the ...
Analysis of an induction regulator for power systems
Analysis of an induction regulator for power systems

... energy market is changing and “owners of the T&D systems will be interested in making the best possible economical use of their assets. In order to remain open to changes on the market, flexibility in investment and flexibility in the control of the networks will become major issues.” In Europe, and ...
40in Gas Furnace Ser..
40in Gas Furnace Ser..

... not prove any operation of the vent system, chimney, because 80% furnaces do not use the induced draft blower to vent products of combustion. (THRU CHIMNEY) These furnaces are Category 1 appliances. Category 1 means these furnaces vent the products of combustion by natural draft. The vent pressure s ...
AT LEAST THE 10 FOLLOWING STEPS OF THE START
AT LEAST THE 10 FOLLOWING STEPS OF THE START

PCF2003 32 kHz watch circuit with programmable adaptive motor
PCF2003 32 kHz watch circuit with programmable adaptive motor

... driving stage is switched to the next level. The correction sequence consists of two pulses: first a short pulse in the opposite direction (0.98 ms, modulated with the maximum duty cycle) to give the motor a defined position, followed by a motor pulse of the strongest driving level. Every 4 minutes, ...
Transformer Protection
Transformer Protection

... As for all current-limiting fuses, the basic application rules found in the fuseology section of this brochure should be adhered to. In addition, potential transformer fuses must have sufficient inrush capacity to successfully pass through the magnetizing inrush current of the transformer. If the fu ...
Phase-shifting Transformer Modeling in PSS®E
Phase-shifting Transformer Modeling in PSS®E

Controlling a brush DC motor with an ST6265
Controlling a brush DC motor with an ST6265

Classic Analog Drives HW Manual
Classic Analog Drives HW Manual

... never touch them while they are working. ...
SHEF40 Submersible/Effluent Pump
SHEF40 Submersible/Effluent Pump

... NOTICE: Do not allow the pump to run in a dry sump. It will void the warranty and may damage the pump. An automatic overload protector in the motor will protect the motor from burning out due to overheating/overloading. When the motor cools down, the overload protector will automatically reset and s ...
Performance Analysis of LLC-LC Resonant Converter Fed
Performance Analysis of LLC-LC Resonant Converter Fed

... of brushes, longer life, better heat dissipation, Higher speed range as no brushes limit its mechanical moment, better efficiency, flat speed and torque characteristics and no experience of slip. In BLDC, the magnetic field generated by the stator and the magnetic field generated by the rotor rotate ...
61/1804-1/2 SANS 1804-1 2007/04/24 2007/06/27
61/1804-1/2 SANS 1804-1 2007/04/24 2007/06/27

... Direct cooled windings Adjustments to take account of hydrogen purity on test Permanently short-circuited windings, magnetic cores and all structural components (other than bearings) whether or not in contact with insulation Commutators and slip-rings, open or enclosed and their brushes and brushgea ...
Merlin 200KW-300KW Large Portable Load Bank
Merlin 200KW-300KW Large Portable Load Bank

section 26 29 23 - variable frequency motor controllers
section 26 29 23 - variable frequency motor controllers

HW manual - TG Drives
HW manual - TG Drives

Power converter optimal control for wind energy conversion systems
Power converter optimal control for wind energy conversion systems

... codes. Nowadays many wind farms use DFIGs, consequently, the field data available was based on this technology. For the offshore wind power industry, a promising technological advance are WECSs that incorporate Permanent Magnet Synchronous Generators (PMSG). For this reason, the second part of this ...
Selector Switch Generator
Selector Switch Generator

0160-5.9 - Rockwell Automation
0160-5.9 - Rockwell Automation

A new design concept of permanent magnet machine for flux
A new design concept of permanent magnet machine for flux

... can be realized without using a position sensor, which is of particular importance to certain applications where the use of a rotating encoder may be prohibited. However, the application of a PM machine is limited by the fixed excitation from permanent magnets. By utilizing a new concept of flux wea ...
Three-phase Transformers
Three-phase Transformers

Transfrormer_Handouts
Transfrormer_Handouts

< 1 ... 7 8 9 10 11 12 13 14 15 ... 226 >

Induction motor



An induction or asynchronous motor is an AC electric motor in which the electric current in the rotor needed to produce torque is obtained by electromagnetic induction from the magnetic field of the stator winding. An induction motor therefore does not require mechanical commutation, separate-excitation or self-excitation for all or part of the energy transferred from stator to rotor, as in universal, DC and large synchronous motors. An induction motor's rotor can be either wound type or squirrel-cage type.Three-phase squirrel-cage induction motors are widely used in industrial drives because they are rugged, reliable and economical. Single-phase induction motors are used extensively for smaller loads, such as household appliances like fans. Although traditionally used in fixed-speed service, induction motors are increasingly being used with variable-frequency drives (VFDs) in variable-speed service. VFDs offer especially important energy savings opportunities for existing and prospective induction motors in variable-torque centrifugal fan, pump and compressor load applications. Squirrel cage induction motors are very widely used in both fixed-speed and variable-frequency drive (VFD) applications. Variable voltage and variable frequency drives are also used in variable-speed service.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report