Industrial Plugs and Sockets
... The plugs and sockets for industrial applications comply with European standards EN 60309-1 (Part 1: General requirements) and EN 60309-2 (Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonised configurations), which are equivalent to international sta ...
... The plugs and sockets for industrial applications comply with European standards EN 60309-1 (Part 1: General requirements) and EN 60309-2 (Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonised configurations), which are equivalent to international sta ...
ETI Research Tellurium Copper Bullet Plugs data
... Additionally, the ETI BulletPlug® features direct 24k gold flashing over the tellurium copper conductor. This eliminates the nickel plating typically found on even the most deluxe and expensive RCA jacks as a third (and dissimilar) metal. The sole reason for using nickel under gold is to provide the ...
... Additionally, the ETI BulletPlug® features direct 24k gold flashing over the tellurium copper conductor. This eliminates the nickel plating typically found on even the most deluxe and expensive RCA jacks as a third (and dissimilar) metal. The sole reason for using nickel under gold is to provide the ...
PI3HDX511F_App_HDMI EVB user Manu_RevA
... In order to provide the flexibility of layout design for source as well as sink applications, the TMDS order of PI3HDX511F can be swapped via TMDS_ORDER pin. The default setting, where TMDS_ORDER is float or 1, is as ...
... In order to provide the flexibility of layout design for source as well as sink applications, the TMDS order of PI3HDX511F can be swapped via TMDS_ORDER pin. The default setting, where TMDS_ORDER is float or 1, is as ...
26 05 19_Electrical Power Conductors and Cables
... Switch legs, travelers, etc., to be consistent with the above phases to which they are connected or may be any other color distinctive from those listed above. Complex control circuits may utilize any combination of colors but the identification shall be by labels throughout. Labeling shall be accom ...
... Switch legs, travelers, etc., to be consistent with the above phases to which they are connected or may be any other color distinctive from those listed above. Complex control circuits may utilize any combination of colors but the identification shall be by labels throughout. Labeling shall be accom ...
G4DDK 23cm VLNA (Very Low Noise Amplifier)
... long HEMT source leads. This technique has been used for many years, but its use has been tempered by the possibility of introducing instability at higher frequencies. Counter intuitively RW3BP has used longer than normal source leads in his improvement to the design. These are in the form of thin c ...
... long HEMT source leads. This technique has been used for many years, but its use has been tempered by the possibility of introducing instability at higher frequencies. Counter intuitively RW3BP has used longer than normal source leads in his improvement to the design. These are in the form of thin c ...
Conductors and Connectors
... All wire and cable for feeder circuits shall conform to the latest requirements of the current edition of the NEC and shall meet all ASTM Specifications. Wire and cable shall be new and have wire size, grade of insulation, voltage, and manufacturer's name permanently marked on outer covering at regu ...
... All wire and cable for feeder circuits shall conform to the latest requirements of the current edition of the NEC and shall meet all ASTM Specifications. Wire and cable shall be new and have wire size, grade of insulation, voltage, and manufacturer's name permanently marked on outer covering at regu ...
RS232 To RS485 Converter
... The Interfacecom RS232 To RS485 Converter allows RS-232 equipment to utilize RS-485 networks, oper-ating in either point-to-point or multi-point, 2-or 4-wire. The RS232 To RS485 Converter is one of the most cost effective RS-485 solutions on the market. Use with your standard PC or Laptop to control ...
... The Interfacecom RS232 To RS485 Converter allows RS-232 equipment to utilize RS-485 networks, oper-ating in either point-to-point or multi-point, 2-or 4-wire. The RS232 To RS485 Converter is one of the most cost effective RS-485 solutions on the market. Use with your standard PC or Laptop to control ...
light-controlled mixer
... Project Box. An inexpensive plastic enclosure designed to hold an electronic circuit. RCA Connector. A small connector, also known as a phono connector, invented by the Radio Corporation of America, and often used in home audio. ...
... Project Box. An inexpensive plastic enclosure designed to hold an electronic circuit. RCA Connector. A small connector, also known as a phono connector, invented by the Radio Corporation of America, and often used in home audio. ...
metalux - Guillevin
... MPC6= Six Foot (6') Modular Power Cord and Plug (specify voltage for plug) F-Bay must be ordered with Modular Receptacle (MP) option in catalog logic. MPC9= Nine Foot (9') Modular Power Cord and Plug (specify voltage for plug) ...
... MPC6= Six Foot (6') Modular Power Cord and Plug (specify voltage for plug) F-Bay must be ordered with Modular Receptacle (MP) option in catalog logic. MPC9= Nine Foot (9') Modular Power Cord and Plug (specify voltage for plug) ...
Basic Electrical Wiring
... Steel fish tape and reel • Pulling conductors through conduit • Pulling cables through insulated walls ...
... Steel fish tape and reel • Pulling conductors through conduit • Pulling cables through insulated walls ...
Electrical Resistance
... Sometimes heating occurs in an electric circuit without excessive current flow. On investigation a defective contact is often found somewhere in the circuit. Whenever conductors are brought together to complete a circuit, such as in a switch or in a plug and socket, it is essential that good contact ...
... Sometimes heating occurs in an electric circuit without excessive current flow. On investigation a defective contact is often found somewhere in the circuit. Whenever conductors are brought together to complete a circuit, such as in a switch or in a plug and socket, it is essential that good contact ...
View
... Depressing the red hold button removes the ground a t pin 16. Q5 turns off, turning off 02, which removes the ground a t the anodes of CR5 and CR6. Relay K2 is held operated by contact K2-A and 03. Transistor 0 3 remains on because loop current through the K3-L winding keeps contact K3 closed, which ...
... Depressing the red hold button removes the ground a t pin 16. Q5 turns off, turning off 02, which removes the ground a t the anodes of CR5 and CR6. Relay K2 is held operated by contact K2-A and 03. Transistor 0 3 remains on because loop current through the K3-L winding keeps contact K3 closed, which ...
Installation guide: Axis P7216
... only the last device in the video signal chain. Network connector - RJ45 Ethernet connector. SFP connector - The unit can only use one Network interface, either an SFP module or RJ45 connector. SFP module has higher priority than the RJ45 connector. NOTICE The product shall be connected using a shie ...
... only the last device in the video signal chain. Network connector - RJ45 Ethernet connector. SFP connector - The unit can only use one Network interface, either an SFP module or RJ45 connector. SFP module has higher priority than the RJ45 connector. NOTICE The product shall be connected using a shie ...
F 3349
... The extension of the time for the inrush current for lamp loads by the appertaining function block is valid for all channels. So inductive and lamp loads may not be operated on one module at the same time. The line break monitoring requires an output load of at least 10 mA. The short-circuit and lin ...
... The extension of the time for the inrush current for lamp loads by the appertaining function block is valid for all channels. So inductive and lamp loads may not be operated on one module at the same time. The line break monitoring requires an output load of at least 10 mA. The short-circuit and lin ...
wire and cable terminology
... Impact Strength: A test for determining the mechanical punishment a cable can withstand without physical or electrical breakdown by impacting with a given weight, dropped a given distance, in a controlled environment. Impedance: The total opposition that a circuit offers to the flow of alternat ...
... Impact Strength: A test for determining the mechanical punishment a cable can withstand without physical or electrical breakdown by impacting with a given weight, dropped a given distance, in a controlled environment. Impedance: The total opposition that a circuit offers to the flow of alternat ...
Klaxon Signalling Solutions
... The beacons should be securely bolted to a suitable surface using the 7mm diameter boltholes in the stainless steel U shaped mounting bracket (see figure 1). The required angle can be achieved by loosening the two large bracket screws in the side of the unit, which allow adjustment of the beacon in ...
... The beacons should be securely bolted to a suitable surface using the 7mm diameter boltholes in the stainless steel U shaped mounting bracket (see figure 1). The required angle can be achieved by loosening the two large bracket screws in the side of the unit, which allow adjustment of the beacon in ...
Raychem Elastomeric Insulating Bushing Boot RCAB
... properties and environmental resistance, giving superb performance in areas of high humidity and electrical stress. Raychem RCAB-Boots work in combination with all Raychem termination product lines including both elastomeric and traditional heatshrink technology. Raychem RCAB-Boots are quick and eas ...
... properties and environmental resistance, giving superb performance in areas of high humidity and electrical stress. Raychem RCAB-Boots work in combination with all Raychem termination product lines including both elastomeric and traditional heatshrink technology. Raychem RCAB-Boots are quick and eas ...
Industry photo: should be a the same image as larger
... and sensor solutions for home appliances and devices, lighting, HVAC, security, and more, TE is the ideal partner to help you bring your products to market fast. ...
... and sensor solutions for home appliances and devices, lighting, HVAC, security, and more, TE is the ideal partner to help you bring your products to market fast. ...
TR1503
... Our standard cable for speaker hookups is the PH50. This cable features 1/4” plugs and 16 gauge copper wire. The PH50 is adequate for lengths up to 50’ under normal use. You can DAISY-CHAIN up to one additional speaker per cable by using the unused 1/4” OUTPUT” jack (right side) on your speaker jack ...
... Our standard cable for speaker hookups is the PH50. This cable features 1/4” plugs and 16 gauge copper wire. The PH50 is adequate for lengths up to 50’ under normal use. You can DAISY-CHAIN up to one additional speaker per cable by using the unused 1/4” OUTPUT” jack (right side) on your speaker jack ...
Thermal Mass Flow Sensors and Meters
... The RED wire (Pin 2 on connector) should be connected to the Positive of the power source. The BLACK wire (Pin 6 on the connector) should be connected to the Negative (Ground) of the power source. The ORANGE wire (Pin 3 on the connector) provides the signal output and should be connected to the posi ...
... The RED wire (Pin 2 on connector) should be connected to the Positive of the power source. The BLACK wire (Pin 6 on the connector) should be connected to the Negative (Ground) of the power source. The ORANGE wire (Pin 3 on the connector) provides the signal output and should be connected to the posi ...
Installation of CT-1
... Step 1. Make certain that the vehicle engine is turned off and allowed to cool to avoid potential accidents and burns. Step 2. Determine where you will place the power supply, coupler and body ground. Make sure that the wire will reach your proposed coupler site and grounding point and can be safely ...
... Step 1. Make certain that the vehicle engine is turned off and allowed to cool to avoid potential accidents and burns. Step 2. Determine where you will place the power supply, coupler and body ground. Make sure that the wire will reach your proposed coupler site and grounding point and can be safely ...
wiring practice
... A typical problem is shown on the following page. The contestant will be given 40 minutes to diagram up to eight of the devices listed below: ...
... A typical problem is shown on the following page. The contestant will be given 40 minutes to diagram up to eight of the devices listed below: ...
Services and Service Equipment CEC-6
... inconsistent application of Code requirements in the province. It is now recognized that the previously permitted installation is not compliant with the Canadian Electrical Code requirement for consumers’ services. Utility-owned equipment such as the commonly-used “economizer/totalizer” for farm ser ...
... inconsistent application of Code requirements in the province. It is now recognized that the previously permitted installation is not compliant with the Canadian Electrical Code requirement for consumers’ services. Utility-owned equipment such as the commonly-used “economizer/totalizer” for farm ser ...
Top 10 Aircraft Wiring Mistakes
... must be the same wire gauge or a larger diameter (smaller gauge number) as the wire that provides power to the device. A ground loop occurs when electricity takes two different paths, and each path has a different resistance. Ground loops are most noticeable in aircraft audio equipment and can prod ...
... must be the same wire gauge or a larger diameter (smaller gauge number) as the wire that provides power to the device. A ground loop occurs when electricity takes two different paths, and each path has a different resistance. Ground loops are most noticeable in aircraft audio equipment and can prod ...
SIMATIC S7 S7-1200 Programmable controller
... This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims all liability for the completeness of this document. It shall only be used for the user's own internal purposes. It shall not be passed on to t ...
... This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims all liability for the completeness of this document. It shall only be used for the user's own internal purposes. It shall not be passed on to t ...
Electrical connector

An electrical connector is an electro-mechanical device for joining electrical circuits as an interface using a mechanical assembly. Connectors consist of plugs (male-ended) and jacks (female-ended). The connection may be temporary, as for portable equipment, require a tool for assembly and removal, or serve as a permanent electrical joint between two wires or devices. An adapter can be used to effectively bring together dissimilar connectors.There are hundreds of types of electrical connectors. Connectors may join two lengths of flexible copper wire or cable, or connect a wire or cable to an electrical terminal.In computing, an electrical connector can also be known as a physical interface (compare physical layer in OSI model of networking). Cable glands, known as cable connectors in the US, connect wires to devices mechanically rather than electrically and are distinct from quick-disconnects performing the latter.