• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
RESS-7-4 working document -in-use f…
RESS-7-4 working document -in-use f…

... means the device for deactivation of the electrical circuit when conducting checks and services of the REESS, fuel cell stack, etc. "Solid insulator" means the insulating coating of wiring harnesses provided in order to cover and protect the live parts against direct contact from any direction of ac ...
Aalborg Universitet Connected Inverter Systems
Aalborg Universitet Connected Inverter Systems

... and thus has a strict requirement of the sampling rate [4], [8], [21]. In contrast, a PLL synchronization method is a closed-loop system, which is widely used in the gridconnected systems [4], [12]. However, for single-phase applications, where only the grid voltage vg is measured, it requires more ...
Category 2
Category 2

... The term “Project” will be used throughout this document to refer to electric generating equipment and  associated facilities that are not owned or operated by an electric utility.  The term “Project Developer”  means a person that owns, operates, or proposes to construct, own, or operate, a Project ...
Planning Guidelines - SUNNY TRIPOWER 60
Planning Guidelines - SUNNY TRIPOWER 60

... • Grid management function • Transformerless • Three-phase • 3-level topology with high performance capacity • Integrated residual current monitoring unit • Insulation test functionality • Extended fault-ride through functions (to support reliable power generation during system incidents) depending ...
Product manual MICRO-0.25/0.3/0.3HV-I-OUTD-US-208/240 ABB solar inverters
Product manual MICRO-0.25/0.3/0.3HV-I-OUTD-US-208/240 ABB solar inverters

... The MICRO inverter is designed to transform direct current (DC) coming from a photovoltaic module (PV) into an alternating current (AC) suitable for being fed into the power distribution grid. ‡ The operating current output during the normal operation MUST NOT exceed the limits documented in the WH ...
10 kW Contactless Power Transfer System for Rapid Charger of
10 kW Contactless Power Transfer System for Rapid Charger of

... transformer for normal charging[2]. It had a novel H-shaped core. We newly developed a 10 kW transformer for rapid charging. This paper describes the characteristics of this transformer. The 10 kW transformer should be compatible with a 1.5 kW transformer for normal charging. To design a 10 kW trans ...
IS-1 ISO uses energy storage for grid operations and
IS-1 ISO uses energy storage for grid operations and

... operations and control The power grid today is a very large and complex “just in time” delivery system that is designed to meet all customers demands for electric energy on a continuous basis. North America Energy Reliability Corporation (NERC) and Western Electricity Coordinating Council (WECC) reg ...
Ausgrid Demand Management Newington Grid Battery Trial
Ausgrid Demand Management Newington Grid Battery Trial

... potentially offer a new alternative solution for the deferral of investments to meet network needs by reducing peak demand experienced by network assets. The installation of batteries behind the meter by customers in order to benefit from reduced electricity bills is also a growing application of ba ...
Touch and Step Potential Calculations
Touch and Step Potential Calculations

... The resistivity properties of the soil where the earthing grid will be laid is an important factor in determining the earthing grid's resistance with respect to remote earth. Soils with lower resistivity lead to lower overall grid resistances and potentially smaller earthing grid configurations can ...
Grid Code
Grid Code

... switching points with a disconnection function (circuit breakers and disconnectors). This connection points are defined by ENE, taking into account the prevailing grid conditions, the power and the way in which the plant operates, as well as the interests of the connectee. Based on the grid connecti ...
Optimizing Strain Gage Excitation Levels
Optimizing Strain Gage Excitation Levels

... To be certain that the excitation level chosen for a given strain gage application is not excessive, it is necessary to run performance tests at the maximum environmental temperature. In many cases, however, this rather complicated procedure can be greatly simplified by gradually increasing the brid ...
Planning and application of electrical drives
Planning and application of electrical drives

... The cooling system for compact drives is mostly based on liquid coolants, which has a higher heat capacity than air. The indirect liquid cooling has come out on top (e. g. 50% water, 50% glycol due to freezing protection), which carries heats away from power electronics and housing of the machine. D ...
Enhanced Frequency Control Capability (EFCC)
Enhanced Frequency Control Capability (EFCC)

... locations, one of which would allow for combining battery storage with a solar PV plant. Beletric where chosen as a project partner for the provision of battery storage and solar PV power plant for frequency response within EFCC through a competivive tender process in line with all partner selection ...
EVSTF09-10-TF6-01
EVSTF09-10-TF6-01

... battery materials, particularly in the non-aqueous electrolytes, is dominating over their physical electrical energy (6). Whether the rate of the energy release or the total energy released is the more critical effect related to a propagating thermal runaway and finally for the vehicle-level risk ha ...
Cálculo de Puesta a Tierra
Cálculo de Puesta a Tierra

... cables, etc). Therefore a current division factor must be applied to account for the proportion of the fault current flowing back through remote earth. Computing the current division factor is a task that is specific to each project and the fault location and it may incorporate some subjectivity (i. ...
Economic Optimal Operation of Community Energy Storage
Economic Optimal Operation of Community Energy Storage

... with solar power generation and energy storage under a Time of Use (TOU) price scheme. However, the real-time electricity market and the effect of time varying loads were not considered in the demand control algorithm. Much literature has focused on utility scale energy storage applications (battery ...
- MATEC Web of Conferences
- MATEC Web of Conferences

... to solve the problems of short-circuit current over-limited of Pengcheng substation in Guangdong power grid and verified those measures from different aspects, which has certain guiding significance to the engineering practice, but this paper didn’t touch on the UHV project. Literature [5] disclosed ...
OpenDSS Introductory Training Level 1
OpenDSS Introductory Training Level 1

... • DSS was developed to provide a very flexible research platform and a foundation for special distribution analysis applications such as DG analysis • Fills gaps left by other distribution system analysis tools. – These do very well in traditional distribution system analysis meeting the needs of th ...
High-Temperature Cuprate Superconductors Get to Work
High-Temperature Cuprate Superconductors Get to Work

... the HTS applications leading the charge to commercial- such local properties as the superconducting energy gap ization were not even mentioned in the early Time article that indicates the strength of superconductivity. Furtherand even today are not widely recognized: They are dy- more, because the e ...
Control of Grid Side Inverter in a B2B Configuration for WT
Control of Grid Side Inverter in a B2B Configuration for WT

... to their longitudinal axes. Below rated wind speed, blades are pitched for optimum power extraction whereas above the rated wind speed blades are pitched to small angle of attack for limiting the power. Advantages of this type of control are good power control performance, assisted start-up and emer ...
Modeling and Energy Consumption Determination of an Electric Go
Modeling and Energy Consumption Determination of an Electric Go

... An electric traction motor drive for an electric karting application was modeled for efficiency studies and simulated using the Matlab®/Simulink® software. In this thesis, the electric traction motor drive model includes models of battery, power electronic converter, and electric motor losses relate ...
Residential Load Models for Network Planning Purposes
Residential Load Models for Network Planning Purposes

... of the fast heating of the water when needed. All-electric customers use electricity also for space heating. This is often done with night-storage heaters to use inexpensive energy and the available network capacity during the night hours. Appliances used with electrical energy may substitute others ...
SECTION 26 05 33.23
SECTION 26 05 33.23

... Interior illuminates when door is open. Door closes automatically to meet while-in-use requirements. ...
SECTION 16492
SECTION 16492

... Interior illuminates when door is open. Door closes automatically to meet while-in-use requirements. ...
Final User Smart Grid Trainer AEL-FUSG Technical Teaching Equipment
Final User Smart Grid Trainer AEL-FUSG Technical Teaching Equipment

... This module can communicate with one or more smart meters. Once the user is communicating with the smart meter from the data concentrator, a platform web can be open. The platform web is integrated in the data concentrator and we can see all electrical parameters of the smart meters that are connect ...
< 1 2 3 4 5 6 ... 19 >

Vehicle-to-grid



Vehicle-to-grid (V2G) describes a system in which plug-in electric vehicles, such as electric cars (BEVs) and plug-in hybrids (PHEVs), communicate with the power grid to sell demand response services by either returning electricity to the grid or by throttling their charging rate.Vehicle-to-grid can be used with gridable vehicles, that is, plug-in electric vehicles (BEVs and PHEVs), with grid capacity. Since at any given time 95 percent of cars are parked, the batteries in electric vehicles could be used to let electricity flow from the car to the electric distribution network and back. This represents a value to the utilities of up to $4,000 per year per car.One notable V2G project in the United States is at the University of Delaware, where a V2G team headed by Dr. Willett Kempton has been conducting on-going research.An early operational implementation in Europe was conducted via the German government-funded MeRegioMobil project at the ""KIT Smart Energy Home"" of Karlsruhe Institute of Technology in cooperation with Opel as vehicle partner and utility EnBW providing grid expertise.Their goals are to educate the public about the environmental and economic benefits of V2G and enhance the product market.Other investigators are the Pacific Gas and Electric Company, Xcel Energy, the National Renewable Energy Laboratory, and, in the United Kingdom, the University of Warwick.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report