Hospital Outpatient Prospective Payment System and CY 2009
... methodology in 2007. As a result, CMS created the distinction between “STVX-packaged” and “Tpackaged” which significantly increased the number of single claims for these codes. In this proposed rule, the ACR appreciates the fact that the methodology is much more transparent, but we are concerned tha ...
... methodology in 2007. As a result, CMS created the distinction between “STVX-packaged” and “Tpackaged” which significantly increased the number of single claims for these codes. In this proposed rule, the ACR appreciates the fact that the methodology is much more transparent, but we are concerned tha ...
ACADEMIC PROGRAM RECOMMENDATIONS FOR GRADUATE DEGREES IN MEDICAL PHYSICS AAPM REPORT NO. 79
... In this document, we more strongly reflect the relationship between a core curriculum that all medical physics Masters (M.S.) and Doctoral (Ph.D.) trainees should be well grounded in and the more specific aspects associated with the medical physics subspecialties. Clearly, the core curriculum serves ...
... In this document, we more strongly reflect the relationship between a core curriculum that all medical physics Masters (M.S.) and Doctoral (Ph.D.) trainees should be well grounded in and the more specific aspects associated with the medical physics subspecialties. Clearly, the core curriculum serves ...
Academic Program Recommendations For Graduate Degrees
... In this document, we more strongly reflect the relationship between a core curriculum that all medical physics Masters (M.S.) and Doctoral (Ph.D.) trainees should be well grounded in and the more specific aspects associated with the medical physics subspecialties. Clearly, the core curriculum serves ...
... In this document, we more strongly reflect the relationship between a core curriculum that all medical physics Masters (M.S.) and Doctoral (Ph.D.) trainees should be well grounded in and the more specific aspects associated with the medical physics subspecialties. Clearly, the core curriculum serves ...
Aquilion PRIME - Toshiba Medical Systems Europe
... a Toshiba scanner in our case was the graphic interface which is the same as that of the Asteion Multi. We were delighted to see that due to the short reconstruction time after only two months of using the PRIME our performance had increased to 40 scans during a 9-to-5 working day. It is a pleasure ...
... a Toshiba scanner in our case was the graphic interface which is the same as that of the Asteion Multi. We were delighted to see that due to the short reconstruction time after only two months of using the PRIME our performance had increased to 40 scans during a 9-to-5 working day. It is a pleasure ...
Nigerian Radiation Safety in Diagnostic and Interventional
... Ionizing Radiation Regulations and exposures from practi~es. or sources exempted by the Nigeria Basic Ionizing Radiation Regulations; "personal dose equivalent ", Hp(d) means the dose equivalent in soft tissue below a specified point on the body at the appropriate depth. (The relevant depths for the ...
... Ionizing Radiation Regulations and exposures from practi~es. or sources exempted by the Nigeria Basic Ionizing Radiation Regulations; "personal dose equivalent ", Hp(d) means the dose equivalent in soft tissue below a specified point on the body at the appropriate depth. (The relevant depths for the ...
comparison of localization performance with implanted fiducial
... (depth, 2 cm) per scan (24). The reliability and geometric accuracy of the CBCT system has been reported previously (25). The geometric calibration of the kV cone-beam CT system was performed intermittently based on service to the kV imaging panel and X-ray tube changes. This totaled 12 calibrations ...
... (depth, 2 cm) per scan (24). The reliability and geometric accuracy of the CBCT system has been reported previously (25). The geometric calibration of the kV cone-beam CT system was performed intermittently based on service to the kV imaging panel and X-ray tube changes. This totaled 12 calibrations ...
Optimising contrast enhancement in abdominal CT
... independent of injection rate.1 Contrast enhancement in the liver The most important phases in CT of the liver are the late arterial phase, which occurs 10-15 seconds after arrival of contrast in the aorta, during which hypervascular lesions are most conspicuous, and the portal venous phase, about 5 ...
... independent of injection rate.1 Contrast enhancement in the liver The most important phases in CT of the liver are the late arterial phase, which occurs 10-15 seconds after arrival of contrast in the aorta, during which hypervascular lesions are most conspicuous, and the portal venous phase, about 5 ...
Patient dose from kilovoltage cone beam computed tomography
... = 6.5 cm, and Z = 26 cm at isocenter. In our clinical experience scanning various sites, including thoracic and abdominal regions, this offset geometry provided the optimum image sets, in terms of quality and reconstructed field of view. Unless otherwise stated, the dose values presented here have b ...
... = 6.5 cm, and Z = 26 cm at isocenter. In our clinical experience scanning various sites, including thoracic and abdominal regions, this offset geometry provided the optimum image sets, in terms of quality and reconstructed field of view. Unless otherwise stated, the dose values presented here have b ...
Document
... an x-ray fluoroscope screen. Air may be puffed into the colon to distend it and provide better images – a double contrast study The enema tube is removed after the pictures are taken. ...
... an x-ray fluoroscope screen. Air may be puffed into the colon to distend it and provide better images – a double contrast study The enema tube is removed after the pictures are taken. ...
Development of a Surgical Assistance System for Guiding
... wurde verwendet, um kontinuierlich die Aortenwurzelbewegung in Bildsequenzen mit Kontrastmittelgabe zu detektieren. Die Aortenklappenprothese wird in die fluoroskopischen Bilder eingeblendet und dient dem Chirurg als Leitfaden für die richtige Platzierung der ...
... wurde verwendet, um kontinuierlich die Aortenwurzelbewegung in Bildsequenzen mit Kontrastmittelgabe zu detektieren. Die Aortenklappenprothese wird in die fluoroskopischen Bilder eingeblendet und dient dem Chirurg als Leitfaden für die richtige Platzierung der ...
Kavo Pan eXam Plus - KaVo. Dental Excellence.
... transmitting equipment, cellular phones etc. shall not be used in close proximity of the unit as they could influence the performance of the unit. ...
... transmitting equipment, cellular phones etc. shall not be used in close proximity of the unit as they could influence the performance of the unit. ...
Computed Tomography Radiation Safety Issues in Ontario
... substantially over the past decade, resulting in growing concern over the radiation dose from CT. CT technological advances, such as the 64-slice CT scanner released in 2005, have led to new clinical CT applications that could result in further increases in patient radiation dose. Purpose of this Re ...
... substantially over the past decade, resulting in growing concern over the radiation dose from CT. CT technological advances, such as the 64-slice CT scanner released in 2005, have led to new clinical CT applications that could result in further increases in patient radiation dose. Purpose of this Re ...
accepted manuscript
... High-resolution X-ray Computed Tomography (HRXCT) or micro-CT (µCT) is a frequently used non-destructive 3D imaging and analysis technique for the investigation of internal structures of a large variety of objects, including geomaterials. Although the possibilities of X-ray micro-CT are becoming bet ...
... High-resolution X-ray Computed Tomography (HRXCT) or micro-CT (µCT) is a frequently used non-destructive 3D imaging and analysis technique for the investigation of internal structures of a large variety of objects, including geomaterials. Although the possibilities of X-ray micro-CT are becoming bet ...
A Monte Carlo dose simulation of chest and hip joint tomosynthesis
... Diagnostic imaging of the chest is made difficult by the many different types of diseases encountered. Radiographic evaluation of the chest can be used to evaluate nodular disease, airway disease and diffuse interstitial disease, placement of tubes and lines, and structures of the mediastinum or spi ...
... Diagnostic imaging of the chest is made difficult by the many different types of diseases encountered. Radiographic evaluation of the chest can be used to evaluate nodular disease, airway disease and diffuse interstitial disease, placement of tubes and lines, and structures of the mediastinum or spi ...
Stroke CT Angiography (CTA) - Vanderbilt University Medical Center
... methods for measuring small (<1–1.5 mm) vascular stenosis are under investigation. Iodinated Contrast Risk. The risks of routine i.v. contrast administration accompany CTA, including the possibility of allergic or idiosyncratic reactions or glomerular injury. Compared with US and MRA, which do not r ...
... methods for measuring small (<1–1.5 mm) vascular stenosis are under investigation. Iodinated Contrast Risk. The risks of routine i.v. contrast administration accompany CTA, including the possibility of allergic or idiosyncratic reactions or glomerular injury. Compared with US and MRA, which do not r ...
Web-based system for Quality Assurance of Radiation Oncology
... scheduling tests, keeping trends of the test results and providing safe storage for the collected data. Our system is based on Drupal, an open source web content management system. Several customizations were done to the basic Drupal system to adapt it to our needs: several scripts and specialized m ...
... scheduling tests, keeping trends of the test results and providing safe storage for the collected data. Our system is based on Drupal, an open source web content management system. Several customizations were done to the basic Drupal system to adapt it to our needs: several scripts and specialized m ...
The following scientific article was officially published in
... in order to generate CT-like data for rigid registration of cadaveric vertebral bodies with X-ray images. A mapping function from MR to simulated CT was obtained using training data. Results showed an improvement when compared to direct use of MRI data. Markelj et al. [111, 112] used as little as 2 ...
... in order to generate CT-like data for rigid registration of cadaveric vertebral bodies with X-ray images. A mapping function from MR to simulated CT was obtained using training data. Results showed an improvement when compared to direct use of MRI data. Markelj et al. [111, 112] used as little as 2 ...
A fluoroscopy-based planning and guidance software tool
... systems have become available that use a combination of pre-operative CT and intraoperative fluoroscopy. One such example is XperGuide (Philips, Best, the Netherlands) [16,25], where the accurate alignment of the patient, fluoroscopy images and the CT image volume depends on ...
... systems have become available that use a combination of pre-operative CT and intraoperative fluoroscopy. One such example is XperGuide (Philips, Best, the Netherlands) [16,25], where the accurate alignment of the patient, fluoroscopy images and the CT image volume depends on ...
Carter: Digital Radiography and PACS
... TOP: Exposure indicator number 31. As Kodak exposure indicator numbers increase by 300, exposure ______. a. Increases by a factor of 2 b. Decreases by a factor of 4 c. Increases by a factor of 4 d. Decreases by a factor of 2 ANS: A OBJ: Compare exposure indicators for major manufacturers. TOP: Expo ...
... TOP: Exposure indicator number 31. As Kodak exposure indicator numbers increase by 300, exposure ______. a. Increases by a factor of 2 b. Decreases by a factor of 4 c. Increases by a factor of 4 d. Decreases by a factor of 2 ANS: A OBJ: Compare exposure indicators for major manufacturers. TOP: Expo ...
Dental Regulatory Guide - Minnesota Department of Health
... Registrants who purchase additional x-ray equipment must submit a registration using the current application process provided by the commissioner and submit a fee for each new tube within 30 days of obtaining the equipment and prior to use. Registrants must notify MDH when there is a change in ...
... Registrants who purchase additional x-ray equipment must submit a registration using the current application process provided by the commissioner and submit a fee for each new tube within 30 days of obtaining the equipment and prior to use. Registrants must notify MDH when there is a change in ...
European Commission. European guidelines on radiation protection
... permanently altered (a mutation). This may lead ultimately to the formation of a tumour. The latent period between exposure to X-rays and the clinical diagnosis of a tumour may be many years. The risk of a tumour being produced by a particular X-ray dose can be estimated; therefore, knowledge of the ...
... permanently altered (a mutation). This may lead ultimately to the formation of a tumour. The latent period between exposure to X-rays and the clinical diagnosis of a tumour may be many years. The risk of a tumour being produced by a particular X-ray dose can be estimated; therefore, knowledge of the ...
Geometric Accuracy of 3-D X-Ray Image
... in Table 2. As one would expect, the localization error is at its lowest point at an angular difference close to 90o . This does not only hold for the primary and secondary angle, but also for combinations as long as the combined angular difference is roughly about 90o . Note that, some viewing angles ...
... in Table 2. As one would expect, the localization error is at its lowest point at an angular difference close to 90o . This does not only hold for the primary and secondary angle, but also for combinations as long as the combined angular difference is roughly about 90o . Note that, some viewing angles ...
MR Imaging of the Spleen - Geisel School of Medicine
... can affect the spleen. Pathologic conditions of the spleen can be classified into the following categories: congenital diseases (accessory spleen, polysplenia, and asplenia); trauma; inflammation (abscess, candidiasis, histoplasmosis, and sarcoidosis); vascular disorders (infarction, diseases affect ...
... can affect the spleen. Pathologic conditions of the spleen can be classified into the following categories: congenital diseases (accessory spleen, polysplenia, and asplenia); trauma; inflammation (abscess, candidiasis, histoplasmosis, and sarcoidosis); vascular disorders (infarction, diseases affect ...
Generalized DQE analysis of radiographic and dual‐energy imaging
... acquired at lower energy 共e.g., 60 kVp兲 will have higher bone contrast than an image acquired at a higher energy 共e.g., 120 kVp兲 due to calcium in the bone. A common algorithm for DE image reconstruction, derived from the straightforward manipulation of Beer’s law, is weighted log subtraction. While ...
... acquired at lower energy 共e.g., 60 kVp兲 will have higher bone contrast than an image acquired at a higher energy 共e.g., 120 kVp兲 due to calcium in the bone. A common algorithm for DE image reconstruction, derived from the straightforward manipulation of Beer’s law, is weighted log subtraction. While ...
Fluoroscopy
Fluoroscopy /flɔrˈɒskəpi/ is an imaging technique that uses X-rays to obtain real-time moving images of the interior of an object. In its primary application of medical imaging, a fluoroscope /ˈflɔrɵˌskoʊp/ allows a physician to see the internal structure and function of a patient, so that the pumping action of the heart or the motion of swallowing, for example, can be watched. This is useful for both diagnosis and therapy and occurs in general radiology, interventional radiology, and image-guided surgery. In its simplest form, a fluoroscope consists of an X-ray source and a fluorescent screen, between which a patient is placed. However, since the 1950s most fluoroscopes have included X-ray image intensifiers and cameras as well, to improve the image's visibility and make it available on a remote display screen. For many decades fluoroscopy tended to produce live pictures that were not recorded, but since the 1960s, as technology improved, recording and playback became the norm.Fluoroscopy is similar to radiography and X-ray computed tomography (X-ray CT) in that it generates images using X-rays. The original difference was that radiography fixed still images on film whereas fluoroscopy provided live moving pictures that were not stored. However, today radiography, CT, and fluoroscopy are all digital imaging modes with image analysis software and data storage and retrieval. The use of X-rays, a form of ionizing radiation, requires the potential risks from a procedure to be carefully balanced with the benefits of the procedure to the patient. Because the patient must be exposed to a continuous source of x-rays instead of a momentary pulse, a fluoroscopy procedure generally subjects a patient to a higher absorbed dose of radiation than an ordinary (still) radiograph. Much research has been directed toward reducing radiation exposure, and recent advances in fluoroscopy technology such as digital image processing and flat panel detectors, have resulted in much lower radiation doses than former procedures.The type of fluoroscopy used in airport security (to check for hidden weapons or bombs) uses lower doses of radiation than medical fluoroscopy. It was formerly also used in retail stores in the form of shoe-fitting fluoroscopes, but such use was discontinued because it is no longer considered acceptable to use radiation exposure, however small the dose, for nonessential purposes. Only important applications such as health care, bodily safety, food safety, nondestructive testing, and scientific research meet the risk-benefit threshold for use. The reason for higher doses in medical applications is that they are more demanding about tissue contrast, and for the same reason they sometimes require contrast media.