• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Hologic HTC Grids Article
Hologic HTC Grids Article

... The total number of objects visible on the films of the phantom without additional absorber was 13 for the HTC grid images and 12 for the linear grid images, an improvement due to the increased contrast with the HTC grid. In addition, the contrast (density difference) between the acrylic disc and th ...
Atlas-based rib-bone detection in chest X-rays
Atlas-based rib-bone detection in chest X-rays

... noise and sampling artifacts during acquisition, and (iii) deformation of tissues and anatomical shape variations caused by disease. Rib border contrast is generally poor/low because of the similar intensity values at the rib boundaries and nearby tissues. In addition to these challenges, rib bone a ...
Tomosynthesis used for a diagnostic mammogram identifies a true
Tomosynthesis used for a diagnostic mammogram identifies a true

... The 1-mm thin sections essentially remove overlapping breast tissue, revealing true abnormalities, while allowing one to correctly dismiss summation shadows. Studies have shown that it has superior sensitivity with enhanced specificity in the screening setting. Diagnostic mammograms performed after ...
QIBA proffered UPICT protocol for solid tumors - QIBA Wiki
QIBA proffered UPICT protocol for solid tumors - QIBA Wiki

... initiation of treatment, and in no case more than a certain number of days before treatment as specified in the clinical protocol. ...
Ct scan code 2016
Ct scan code 2016

... imaginghealthcare.com A lumbar spine CT scan carries very few risks. The contrast dye used during the procedure may cause temporary TEENney damage, though. This risk is higher if your. What is CT Scanning of the Body? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic medi ...
dual energy
dual energy

... • Early detection of cancer • Reliable measurements of tumors in a reproducible way • Still need for high dose of contrast in repetitive manner • Drug tracking • Tumor vascular studies- e.g. perfusion ...
Image Acquisition Site - QIBA Wiki
Image Acquisition Site - QIBA Wiki

... A. A discussion has been added to address dose issues. Increased radiation absorbed dose improves SNR and gives better lesion definition up to a point. ...
Follow‑up after focal therapy in renal masses: an
Follow‑up after focal therapy in renal masses: an

... chest and abdomen, no other routine follow-up for metastasis is advised (consensus 83 %). KT 5. The role of biopsy during follow‑up Online agreement (85 %) was reached that post-FT biopsy should not be acquired routinely during follow-up. The participants agree (85 %) that the literature was not cle ...
Radiation risk from mammography - Hendrick
Radiation risk from mammography - Hendrick

... Like previous ICRP reports, the updated 2007 ICRP report quantifies radiation risk by using the concept of effective dose (13–15). Effective dose is the ionizing radiation exposure to the entire body that would result in equivalent detriment as exposure over a more limited region of the body. In the ...
Adjusting kV to Improve Image Quality or Reduce Radiation Dose
Adjusting kV to Improve Image Quality or Reduce Radiation Dose

... The widely used relation “Radiation output CTDIvol is proportional to kVp2 for the same mAs” is not accurate. As shown above, the actual CTDIvol at 80 kVp is about ~50% lower on both GE and Siemens scanners for the lower kV’s ...
Is nuclear imaging a viable alternative technique to assess
Is nuclear imaging a viable alternative technique to assess

... reliable results. The recent report from the Predictors of Response to Cardiac Resynchronization Therapy trial showed that under ‘real-world’ conditions the current available echocardiographic techniques including tissue Doppler imaging (TDI) and myocardial strain-rate imaging are not ready for rout ...
Intraoral radiographic images can be acquired with digital receptors
Intraoral radiographic images can be acquired with digital receptors

... Digital images can be adjusted to view the information in different ways. Software enhancement features include changes in density, contrast, colorization, zoom or magnification of particular areas of interest, measurement, image reversal and the application of filters for noise reduction or edge sh ...
Outpatient Medical Imaging Orders
Outpatient Medical Imaging Orders

... Please arrive 15 minutes (unless otherwise instructed) before your exam and bring this referral form with you. If your exam is not listed, no specific preparation is required. CT Scan Take nothing by mouth 1 hour prior to the exam. Take all regularly prescribed medications. Please notify the recepti ...
Positron Emission Tomography - PET
Positron Emission Tomography - PET

... • For a lytic lesion to be visualized by radiography localized demineralization of 30-50% must occur • Bone scans usually demonstrate metastatic lesions much earlier than radiography • False negative bone scan: ...
The Pathway to Dominating Radiology and Imaging
The Pathway to Dominating Radiology and Imaging

... Airpower and on the ground military power separately, cannot win a conflict. Together; however, the combination can be devastating. – Anonymous. A report from Transparency Market Research recently stated that the global teleradiology market was worth approximately $0.92 billion in 2012. The estimati ...
Positron Emission Tomography - PET
Positron Emission Tomography - PET

... • For a lytic lesion to be visualized by radiography localized demineralization of 30-50% must occur • Bone scans usually demonstrate metastatic lesions much earlier than radiography • False negative bone scan: ...
MS-32.667 - TU Delft Repositories
MS-32.667 - TU Delft Repositories

... For the modified low contrast CTDI phantom the best results are obtained with the (83 kV, 561 mA, 0.4 Cu) – protocol. This protocol may improve iodine contrast agent visibility in various 3D imaging applications. For large patients a higher tube voltage, e.g. the (103 kV, 325 mA, 0.4 Cu) – protocol, ...


... periaortic fat is visible, including deformation of the lumen [12, 19] (fig. 3). Furthermore, in selected cases focal enhancement of the aortic wall after contrast in the area of adjacent tumour tissue may indicate malignant invasion. Coronal or sagittal MR images are extremely valuable in determini ...
National Ultrasound Curriculum for Medical Students
National Ultrasound Curriculum for Medical Students

... In the preclinical years, the US curriculum can be integrated into the overall curriculum to supplement general understanding of anatomy, physiology, and pathology.13,14 This horizontal incorporation of a US curriculum is likely best organized and implemented by a multidisciplinary group including r ...
Anterior Segment Optical Coherence Tomography in Glaucoma
Anterior Segment Optical Coherence Tomography in Glaucoma

... anterior segment imaging due to two significant properties. First, the amount of scattering in tissue is lower at this wavelength. This enables increased penetration through scattering ocular structures such as the sclera and the iris so that more detailed anterior segment morphology is visualized. ...
RADIATION PROTECTION IN DIAGNOSTIC RADIOLOGY
RADIATION PROTECTION IN DIAGNOSTIC RADIOLOGY

... • To become familiar with basic knowledge of the component that form the radiographic chain. ...
molecular imaging center, nirs
molecular imaging center, nirs

... the visualization of these molecules. The 4 important technologies that have been established in the field of molecular imaging comprise PET, SPECT, MRI, and fluorescence imaging. PET and SPECT are considerably effective in whole-body imaging of human subjects; similarly, MRI is effective for imagin ...
Comparison of Multiple Sclerosis Lesions at 1.5 and 3.0 Tesla
Comparison of Multiple Sclerosis Lesions at 1.5 and 3.0 Tesla

... enhancing lesions. The greater sensitivity of the higher field scanner can lead to higher relative lesions counts, but could also result in the inclusion of subjects into a clinical trial who have disease characteristics that differ from those at other centers using lower field strength scanners. Th ...
el_hawary - Workspace - Imperial College London
el_hawary - Workspace - Imperial College London

... first displays a transverse scan of the tendon aligned with the main field and displaying virtually no signal and the second shows the tendon at the magic angle with its corresponding increase in signal. Fig. 4(c) presents a graph displaying the average normalised signal of the Achilles tendon (take ...
here - IROC Houston
here - IROC Houston

... the motor controller. The phantom will home, pause, and then begin its motion pattern. It may make a rattling noise during pauses in the motion – that’s normal. 10. CT the phantom as you would a patient, including immobilization techniques. You may wish to scan with 1.5 mm slices especially near the ...
< 1 ... 65 66 67 68 69 70 71 72 73 ... 173 >

Image-guided radiation therapy

Image-guided radiation therapy (IGRT) is the process of frequent two and three-dimensional imaging, during a course of radiation treatment, used to direct radiation therapy utilizing the imaging coordinates of the actual radiation treatment plan. The patient is localized in the treatment room in the same position as planned from the reference imaging dataset. An example of IGRT would include localization of a cone beam computed tomography (CBCT) dataset with the planning computed tomography (CT) dataset from planning. IGRT would also include matching planar kilovoltage (kV) radiographs or megavoltage (MV) images with digital reconstructed radiographs (DRRs) from the planning CT. These two methods comprise the bulk of IGRT strategies currently employed circa 2013.This process is distinct from the use of imaging to delineate targets and organs in the planning process of radiation therapy. However, there is clearly a connection between the imaging processes as IGRT relies directly on the imaging modalities from planning as the reference coordinates for localizing the patient. The variety of medical imaging technologies used in planning includes x-ray computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET) among others. The precision of IGRT is significantly improved when N-localizer technology is used in conjunction with these medical imaging technologies. Through advancements in imaging technology, combined with a further understanding of human biology at the molecular level, the impact of IGRT on radiotherapy treatment continues to evolve.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report