• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
high-resolution imaging in nontransparent tissue
high-resolution imaging in nontransparent tissue

... it should be applied, both with respect to patient safety and controlling health care costs. The appropriate clinical scenarios for application of this technology need to be identified since, in many circumstances, it is difficult to justify replacing a gold standard like excisional biopsy. For exam ...
Diagnostic Radiology Training Requirements
Diagnostic Radiology Training Requirements

... b. patient and medical personnel safety (i.e., radiation protection); c. the chemistry of by-product material for medical use; d. biologic and pharmacologic actions of materials administered in diagnostic and therapeutic procedures; and, e. topics in safe handling, administration, and quality contro ...
Diagnostic Radiology - All Healthcare Professionals
Diagnostic Radiology - All Healthcare Professionals

... b. patient and medical personnel safety (i.e., radiation protection); c. the chemistry of by-product material for medical use; d. biologic and pharmacologic actions of materials administered in diagnostic and therapeutic procedures; and, e. topics in safe handling, administration, and quality contro ...
Biologic Effects - Michigan State University
Biologic Effects - Michigan State University

... the tissues • Some tissue heating may take place – (applications of ultrasound for cancer therapy) • Importance of using the lowest power level available for the imaging task at hand • Especially important when imaging embryos and fetuses ...
Contrast Optimization in Low Radiation Dose Imaging
Contrast Optimization in Low Radiation Dose Imaging

... 7. Furuta A, Ito K, Fujita T, Koike S, Shimizu A, Matsunaga N. Hepatic enhancement in multiphasic contrast-enhanced MDCT: Comparison of high- and low-iodineconcentration contrast medium in same patients with chronic liver disease. Am J Roentgenol. 2004;183:157–162. 8. Rau MM, Setty BN, Blake MA, Oue ...
High-dose MVCT image guidance for stereotactic body
High-dose MVCT image guidance for stereotactic body

... The ability to resolve contrast differences in an image is fundamentally limited by the number of photons detected during acquisition. If the number of photons is too small, noise will dominate the image—making the borders between different contrast regions indistinguishable. MV imaging systems are ...
Your Answer - University of Florida
Your Answer - University of Florida

... the base of the lung greater than 50 mm corresponds to a pleural effusion greater than: A. 50 mL B. 500 mL C. 1000 mL D. 1500 mL 5. T or F: When performing thoracentesis, the patient should not be moved in between ultrasound imaging and needle puncture when real time ultrasound is not used A. True B ...
THE SNM PROCEDURE GUIDELINE FOR GENERAL IMAGING 6.0
THE SNM PROCEDURE GUIDELINE FOR GENERAL IMAGING 6.0

... The parameters employed will depend greatly on the number of detectors incorporated into the camera. For a single head camera, the general matrix size will normally be 64 x 64. For multi-head cameras, the matrix size will be 64 x 64 or 128 x 128 for higher resolution studies. The manufacturer’s proc ...
ACRIN Breast Committee Overview
ACRIN Breast Committee Overview

... •Assess the use of imaging for the measurement of extent of disease and for monitoring and mid-therapy adaptation of treatment protocols. •Reduce the morbidity of breast cancer therapy through noninvasive imaging-guided mechanisms. ACRIN Breast Committee ...
- World Scientific
- World Scientific

... of Bayesian MAP estimators. Our experimental designs are described as follows: 1. We chose MRI images as the source to provide the prior information. We used SIEMENS Vision plus 1.5-T scanner. The scan parameters were TEITR = 14/500 s, scan matrix = 256 x 256. The data set was acquired from an axial ...
Application of Chemical Exchange Saturation Transfer (CEST)
Application of Chemical Exchange Saturation Transfer (CEST)

... and amide proton transfer asymmetry (APTasym) was calculated for the amide resonance (3.5 ppm). ROIs were manually drawn based on the anatomical images. MT ratio (MTR) maps were also calculated.(6) RESULTS & DISCUSSION Representative results from a healthy control (Fig.1A-B), and MS subject (Fig.1C- ...
MODALITY CAPSULE REVIEWS Diffusion
MODALITY CAPSULE REVIEWS Diffusion

... Introduction: Diffusion-weighted imaging (DWI-MRI) has moved from a research tool, to, in some scenarios, discussed below, a clinically relevant and applicable modality to apply to the imaging and management of rectal adenocarcinoma. This capsule will discuss its use from the standpoint of diagnosis ...
Product Information
Product Information

... body imaging. Improved patient compliance and image quality through faster rotation times and less susceptibility to motion artifacts with sub-millimeter image quality for visualization of subtle abnormalities. Rotation speed without compromise for sharp, precise and virtually motion free images of ...
Installation of Imaging Modalities
Installation of Imaging Modalities

... Boys Town National Research Hospital: Research and Diagnostic 3.0T MRI ...
Spect scan cpt code 2017 - Tamoxifen high risk med icd 10 code
Spect scan cpt code 2017 - Tamoxifen high risk med icd 10 code

... �It has been of high luster which. 660 holding where bill of the charge to there is a special entire. Him from denying that follow as a matter at spect scan cpt code 2017 assign it. To what will roblox error code 102 they were unusually distinct. 16 holding witnesses to statutes last above given. Th ...
Compute Tomography
Compute Tomography

... For each rotation of the x-ray source and detector, the image data are sent to a computer to reconstruct all of the individual "snapshots" into one or multiple crosssectional images (slices) of the internal organs and ...
EXAM: WHITE BLOOD CELL IMAGING
EXAM: WHITE BLOOD CELL IMAGING

... post injection. These images will last approximately 30 minutes. Additional images will be performed 2 to 4 hours post injection and require approximately 1 hour to accomplish. Images at 24 hours post injection may be required, these images last 1 to 2 hours. The study is completed after the images ...
Liver Lesion (Incidental) - Diagnostic Imaging Pathways
Liver Lesion (Incidental) - Diagnostic Imaging Pathways

... Considered better than CT for identifying cystic hepatic lesions 16 The use of quantitative dynamic contrast enhanced ultrasound (CEUS) has been found to improve the characterisation of focal liver lesions 3,4 with enhancement patterns observed during the arterial, portal venous and late phases gene ...
171_eposter - Stanley Radiology
171_eposter - Stanley Radiology

...  Inadequate surgery – leading cause of recurrence  Over excision may lead to Anal incontinence  MR Fistulography  Provide adequate anatomical delineation of fistula preoperatively  Aid surgeon to plan the appropriate approach  Reduced risk of recurrence ...
Cone Beam Imaging in Patients with Temporomandibular Disorders.
Cone Beam Imaging in Patients with Temporomandibular Disorders.

... or regular or conforming to a norm) "abnormal powers of concentration"; "abnormal amounts of rain"; "abnormal circumstances"; "an abnormal interest in food” (adj) abnormal (departing from the normal in e.g. intelligence and development) "they were heartbroken when they learned their child was abnorm ...
Development of a high-resolution and high efficiency single photon
Development of a high-resolution and high efficiency single photon

... required for the imaging system. Many devices have been proposed or developed, each with different performance characteristics [12]. Most of them are based on the standard Anger camera-based detector with single pinhole and multipinhole collimation [12]. Taking advantage of high geometric efficiency ...
PDF
PDF

... Recent developments in image-guidance and device navigation, along with emerging robotic technologies, are rapidly transforming the landscape of interventional radiology (IR). Future state-of-theart IR procedures may include real-time three-dimensional imaging that is capable of visualizing the targ ...
IX. H. Quality Control Monitors and Imaging Formatter
IX. H. Quality Control Monitors and Imaging Formatter

... The parameters employed will depend greatly on the number of detectors incorporated into the camera. For a single head camera, the general matrix size will normally be 64 x 64. For multi-head cameras, the matrix size will be 64 x 64 or 128 x 128 for higher resolution studies. The manufacturer’s proc ...
Spleen Fine Needle Aspiration
Spleen Fine Needle Aspiration

... splenic involvement. CT shows an enlarged spleen with hypoattenuating lesions on nonenhanced scans and contrast enhancement is variable. ...
acr practice guideline for the performance of thoracic computed
acr practice guideline for the performance of thoracic computed

... The American College of Radiology, with more than 30,000 members, is the principal organization of radiologists, radiation oncologists, and clinical medical physicists in the United States. The College is a nonprofit professional society whose primary purposes are to advance the science of radiology ...
< 1 ... 105 106 107 108 109 110 111 112 113 ... 159 >

Medical imaging



Medical imaging is the technique and process of creating visual representations of the interior of a body for clinical analysis and medical intervention. Medical imaging seeks to reveal internal structures hidden by the skin and bones, as well as to diagnose and treat disease. Medical imaging also establishes a database of normal anatomy and physiology to make it possible to identify abnormalities. Although imaging of removed organs and tissues can be performed for medical reasons, such procedures are usually considered part of pathology instead of medical imaging.As a discipline and in its widest sense, it is part of biological imaging and incorporates radiology which uses the imaging technologies of X-ray radiography, magnetic resonance imaging, medical ultrasonography or ultrasound, endoscopy, elastography, tactile imaging, thermography, medical photography and nuclear medicine functional imaging techniques as positron emission tomography.Measurement and recording techniques which are not primarily designed to produce images, such as electroencephalography (EEG), magnetoencephalography (MEG), electrocardiography (ECG), and others represent other technologies which produce data susceptible to representation as a parameter graph vs. time or maps which contain information about the measurement locations. In a limited comparison these technologies can be considered as forms of medical imaging in another discipline.Up until 2010, 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 made up about 50% of total ionizing radiation exposure in the United States.In the clinical context, ""invisible light"" medical imaging is generally equated to radiology or ""clinical imaging"" and the medical practitioner responsible for interpreting (and sometimes acquiring) the images is a radiologist. ""Visible light"" medical imaging involves digital video or still pictures that can be seen without special equipment. Dermatology and wound care are two modalities that use visible light imagery. Diagnostic radiography designates the technical aspects of medical imaging and in particular the acquisition of medical images. The radiographer or radiologic technologist is usually responsible for acquiring medical images of diagnostic quality, although some radiological interventions are performed by radiologists.As a field of scientific investigation, medical imaging constitutes a sub-discipline of biomedical engineering, medical physics or medicine depending on the context: Research and development in the area of instrumentation, image acquisition (e.g. radiography), modeling and quantification are usually the preserve of biomedical engineering, medical physics, and computer science; Research into the application and interpretation of medical images is usually the preserve of radiology and the medical sub-discipline relevant to medical condition or area of medical science (neuroscience, cardiology, psychiatry, psychology, etc.) under investigation. Many of the techniques developed for medical imaging also have scientific and industrial applications.Medical imaging is often perceived to designate the set of techniques that noninvasively produce images of the internal aspect of the body. In this restricted sense, medical imaging can be seen as the solution of mathematical inverse problems. This means that cause (the properties of living tissue) is inferred from effect (the observed signal). In the case of medical ultrasonography, the probe consists of ultrasonic pressure waves and echoes that go inside the tissue to show the internal structure. In the case of projectional radiography, the probe uses X-ray radiation, which is absorbed at different rates by different tissue types such as bone, muscle and fat.The term noninvasive is used to denote a procedure where no instrument is introduced into a patient's body which is the case for most imaging techniques used.