• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Proton Relaxation Enhancement Associated with Iodinated Contrast
Proton Relaxation Enhancement Associated with Iodinated Contrast

... intraventricular instillation of a water soluble iodinated contrast agent (3 mL of lsovue-300) through an intraventricular shunt to evaluate the patency of the ventricular system in noncommunicating hydrocephalus. A second patient was evaluated on MR approximately 2 hours after lumbar myelography (1 ...
Understanding Radiation Units - Radiation Protection of Patients
Understanding Radiation Units - Radiation Protection of Patients

... • 1000 Watt heater giving off heat (IR radiation) - unit is of power which is related with emission intensity • Heat perceived by the person will vary with so many factors: distance, clothing, room temperature • As can be seen with the example of heat, the energy transformation is a highly complicat ...
Diffusion-weighted MRI in cervical lymph nodes: Differentiation
Diffusion-weighted MRI in cervical lymph nodes: Differentiation

... significant. Subsequently we used a receiver operating characteristic (ROC) curve to evaluate diagnostic capability of ADC value and to determine the cut-off value for differentiating malignant from benign nodes. ...
ecr today 2012
ecr today 2012

... engineering tool for genes, gene delivery in tissue, transdermal delivery of drugs and genes, fusion of cells, introduction of drugs into cells, and electrochemotherapy for treatment of cancer. The problem, though, is that reliable information about electroporation is limited, and ...
Abstract Objective: To assess if the presence of intra
Abstract Objective: To assess if the presence of intra

... cartilage, and linear regressions through the origin yielded estimated slopes very close to 1 and R2 values greater than 0.98. Conclusions: These results indicate that intra-articular injection of Gd-DTPA2-, along the protocol described in this study, has little effect on T2* values of femoral and a ...
RBFM v5n1.indb
RBFM v5n1.indb

... International Organization of Medical Physics (IOMP) decided to hold its international conference in Brazil, thus favoring the participation of local and Latin American professionals The 18th edition of the International Conference on Medical Physics (ICMP 2011), whose subject was “Science and Techn ...
Ce document est le fruit d`un long travail approuvé
Ce document est le fruit d`un long travail approuvé

... - Article 1 : Dose reduction in musculoskeletal CT: Tips and Tricks……………………………. 50 - Article 2 : Imaging follow-up of patients with osteoid osteomas after percutaneous ablative laser therapy: Is there a place for CT perfusion?............................................................... 61 - Artic ...
Evaluation of Palpable Breast Masses
Evaluation of Palpable Breast Masses

... A = consistent, good-quality patient-oriented evidence; B = inconsistent or limited-quality patient-oriented evidence; C = consensus, disease-oriented evidence, usual practice, opinion, or case series. See page 1635 for more information. ...
Summary of Public Comment
Summary of Public Comment

... the proposed rule, experience has not shown any issues with a CT scanner due to disassembly, moving, or major component replacement. I would propose that a reasonable timeframe be substituted for the “before clinical use” in order to more reasonably accomplish the goal of documenting proper performa ...
PPT Version - OMICS International
PPT Version - OMICS International

... effects of Regado's REG1 to bivalirudin in patients undergoing percutaneous coronary intervention (PCI) electively or for the treatment of unstable angina (UA) or non-ST elevated myocardial infarction (NSTEMI). REGULATE-PCI, if successful, will serve as the basis for product registration application ...
Chapter 5 Treatment Machines for External Beam - Phy428-528
Chapter 5 Treatment Machines for External Beam - Phy428-528

... 5.1 INTRODUCTION Specialized machines used for modern radiotherapy: ...
Finger fractures imaging: accuracy of cone-beam
Finger fractures imaging: accuracy of cone-beam

... Moreover, depending on the number of bone fragments depicted at MSCT, the fractures were also classified as a simple fracture (showing only one site of discontinuation of the cortical bone, without any bone fragment), a single fragment fracture (if only one free bone fragment was present), and a com ...
Recognizing the Empty - American Journal of Neuroradiology
Recognizing the Empty - American Journal of Neuroradiology

... to exclude an intrasellar neoplasm, most often a pitu itary adenoma [1-4]. An empty sella can be differentiated effectively but not comfortab ly, from an intrasellar neoplasm by pneumoencephalography or cisternography . Computed tomography (CT) is reported to be sensitive but not specific for the di ...
Innova X-ray Dose Efficiency: Objective Evidence
Innova X-ray Dose Efficiency: Objective Evidence

... distance are those commonly used by clinicians in performing interventional procedures on a given system. Methods and Controls: Studies must be scientific, evidence-based, and preferably peer-reviewed. Given all the sources of variability in interventional procedures, adequate controls for a number ...
article in press - The EndoExperience
article in press - The EndoExperience

... During the last decade, there has been a tendency of using three-dimensional (3D) information to aid in dentomaxillofacial diagnostics and surgery planning [1,2]. Conventional CT protocols are generally associated with relatively high radiation dose levels and even clinical protocols for multi-slice ...
6 The Simulation Process in the Determination and Definition of the
6 The Simulation Process in the Determination and Definition of the

... than bony anatomy, is available for design of treatment portals. Shortly after the introduction of clinical CT scanners in early 1970s, it was realized that this imaging modality has much to offer in a radiation oncology setting. The CT images provide information not only about target volumes but ab ...
!"#$%"&'()*)+,"-$.)/$012+"$342*,56$017/)8"1"(5 $2(9$:)-"$;"94&<)($,($=%$
!"#$%"&'()*)+,"-$.)/$012+"$342*,56$017/)8"1"(5 $2(9$:)-"$;"94&<)($,($=%$

... Dose reduction with X-CARE to Breast Tissue X-CARE: Dose and Image Quality Organ based dose modulation reduces radiation exposure of the breast by 30-40% Noise level is maintained with dedicated reconstruction technique ...
Guideline for Radiation Safety in Interventional Cardiology - J
Guideline for Radiation Safety in Interventional Cardiology - J

... arrhythmias. Interventional cardiology has become increasingly sophisticated, and the indications for it have expanded. This trend has resulted in an increased number of radiationinduced skin injuries and other types of health hazards, such as cataract and hypothyroidism, in those who perform the pr ...
Clinical Applications of Positron Emission Tomography (PET)
Clinical Applications of Positron Emission Tomography (PET)

... (t1/2 = 3.3 days) and iodine-124 (t1/2 = 4.2 days) suffer from having a longer half-life and are more difficult to produce. A major research interest is based on radiochemistry using radionuclide generators such germanium-68/gallium-68 [36]. Using gallium-68 (t1/2 = 68 minutes), many molecules of bi ...
guided radiation therapy
guided radiation therapy

... Many investigators have examined the use of the treatment beam to perform megavoltage (MV) computed tomography (CT) of the patient in treatment position. This was first proposed in 1983 by Swindell et al. (21) and has been extended to a cone-beam implementation by Mosleh-Shirazi et al. (22) Other in ...
Cone beam-computed tomography applications in endodontics: A
Cone beam-computed tomography applications in endodontics: A

... reported that what make these two machines different from other ones were their detectors. I-CAT and Scannora have image intensifier tube/charged coupled device while other three devices - namely, newtome, accuitomo, galileo - have flatpanel detectors (FPD), which cause decreased dynamic range, contr ...
Use of Cross-Sectional Imaging in Predicting Surgical
Use of Cross-Sectional Imaging in Predicting Surgical

... to the superficial or deep lobes. Lesions lateral to the retromandibular vein indicate that the lesions are located in the superficial lobe, whereas lesions medial to the retromandibular vein involve the deep lobe. Knowledge of the location of a parotid mass can be helpful for preoperative planning ...
The Effects of Organ-based Tube Current Modulation on Radiation
The Effects of Organ-based Tube Current Modulation on Radiation

... Healthcare, Chalfont St Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens and brain regions (mobile MOSFET Dosimetry System, Best Medical, Ottawa, Canada) for ODM, AutomA (z-axis modulation), and SmartmA (angular and z-axis modulation) settings. Noise standard devia ...
Radiation dose reduction in computed tomography
Radiation dose reduction in computed tomography

... assurance testing and to describe and optimize the radiation output of a specific scanning tech‑ nique. It is important to realize that these dose metrics are not a direct measurement of patient dose; they are a standardized dose metric to rep‑ resent scanner output levels, when measured in a standa ...
Prognostic value of gated myocardial perfusion SPECT. Shaw L
Prognostic value of gated myocardial perfusion SPECT. Shaw L

... zation. In the area of single photon emission computed tomography (SPECT) imaging, annualized growth rates for cardiologists have increased by more than 20%.2 When one examines all of cardiovascular testing, there are an estimated 40 million noninvasive cardiac tests performed each year.3 For echoca ...
< 1 ... 10 11 12 13 14 15 16 17 18 ... 67 >

Neutron capture therapy of cancer



Neutron capture therapy (NCT) is a noninvasive therapeutic modality for treating locally invasive malignant tumors such as primary brain tumors and recurrent head and neck cancer. It is a two step procedure: first, the patient is injected with a tumor localizing drug containing a non-radioactive isotope that has a high propensity or cross section (σ) to capture slow neutrons. The cross section of the capture agent is many times greater than that of the other elements present in tissues such as hydrogen, oxygen, and nitrogen. In the second step, the patient is radiated with epithermal neutrons, which after losing energy as they penetrate tissue, are absorbed by the capture agent which subsequently emits high-energy charged particles, thereby resulting in a biologically destructive nuclear reaction (Fig.1).All of the clinical experience to date with NCT is with the non-radioactive isotope boron-10, and this is known as boron neutron capture therapy (BNCT). At this time, the use of other non-radioactive isotopes, such as gadolinium, has been limited, and to date, it has not been used clinically. BNCT has been evaluated clinically as an alternative to conventional radiation therapy for the treatment of malignant brain tumors (gliomas), and more recently, recurrent, locally advanced head and neck cancer.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report