• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SIGNA PET-MR and Epilepsy PDF 362KB
SIGNA PET-MR and Epilepsy PDF 362KB

... 32-year-old with a history of epilepsy referred to PET/MR. (C, D) FDG hypometabolism is seen on the prefontal left lobe, complementing (A, B) MR images. CortexID Suite helps with the quantification of the lowered FDG uptake in the prefrontal lateral left region with a z-score of -4.08. ...
Brain Imaging Jigsaw Articles
Brain Imaging Jigsaw Articles

... center of the donut’s hole. Just as with a conventional X-ray machine, the patient is exposed to a small dose of radiation during the scan. The X-ray emission source revolves around the patient on one side, while the Xray detector revolves directly opposite, thus detecting the X-rays that have been ...
Medical imaging in oncology review
Medical imaging in oncology review

... than CT, patients can become claustrophobic in the magnetic tube; ferromagnetic objects such as some pacemakers can be dislodged ...
Medical imaging - Purdue Physics
Medical imaging - Purdue Physics

... Nuclear medicine studies document organ and function and structure, in contrast to conventional radiology, which creates images based upon anatomy. Many of the nuclear medicine studies can measure the degree of function present in an organ, often times eliminating the need for surgery. Moreover, nuc ...
Imaging in oncology - over a century of advances
Imaging in oncology - over a century of advances

... so early response to a variety of treatments can be evaluated using functional techniques. Limitations include the drawback that FDG is not accurate across all tumour histologies and that tissue changes such as inflammation will also take up FDG, so it is not a truly tumour-specific ligand. The othe ...
The Anatomy of Language Sydney Lamb Rice University, Houston
The Anatomy of Language Sydney Lamb Rice University, Houston

...  These areas are assumed to be the most active at the given point in time  The positrons in the isotopes collide with electrons  These collisions produce photons, which can be detected at the surface of the head  The greater the activation of an area, the more positrons originate from that area ...
Lecture 2 Imaging, Brain Development
Lecture 2 Imaging, Brain Development

... – Short half-life means hospital must have an accelerator on-site (very expensive). – A long exposure is required (40 sec) because of low radiation levels. – Low spatial resolution (4 mm) due to annihilation distance. – Images are projections, no anatomical measurements are possible. ...
A short reader`s guide to 3D tomographic reconstruction
A short reader`s guide to 3D tomographic reconstruction

... always regard SPECT as a fully 3D problem. Because of the lower sensitivity of SPECT scanners compared to PET, and also because the data are not well modeled as line integrals of the tracer distribution (the collimator holes de®ne conical tubes of response rather than lines), the best results are ob ...
Magnetic resonance imaging (MRI)
Magnetic resonance imaging (MRI)

... sounds heard during an MR scan. Diseased tissue, such as tumors, can be detected because the protons in different tissues return to their equilibrium state at different rates. By changing the parameters on the scanner this effect is used to create contrast between different types of body tissue. ...
The Center for Clinical Imaging Research (CCIR) at Washington
The Center for Clinical Imaging Research (CCIR) at Washington

... the latest VB17A software platform. The scanner also has proton spectroscopy, and has RF transmitter/receiver electronics for multi-nuclear spectroscopy. The magnet is a relatively short (150 cm or 5'3" in length), whole-body superconductive 1.5T magnet with 5th generation active shielding technolog ...
Tuberculosis: CNS and Respiratory
Tuberculosis: CNS and Respiratory

... and therefore project as areas of high uptake with high SUV on PET scan Infections tend to be less avid for FDG, and therefore project as areas of low uptake with a minimally increased or low SUV on PET scan However this is not a firm rule ! ...
Update On Dose In Radiology - Leading Edge Medical Educational
Update On Dose In Radiology - Leading Edge Medical Educational

... created by backscatter radiation bourn by the exposed individual that have beneficial effects affect future generations ...
PET and DTI imaging of brain injury
PET and DTI imaging of brain injury

... • PET FDG z maps have 5% false positive error rate for statistical z map • PET FDG z-maps have over 90% sensitivity in detecting abnormalities in patients with TBI ...
Magnetic Resonance Imaging: Coil Sensitivity Estimation Michael
Magnetic Resonance Imaging: Coil Sensitivity Estimation Michael

... Fessler Medical Imaging Group ...
computed tomography
computed tomography

... c. Can get highly overlapping images. (Hundreds of images from single 30 second scan) 3. Comparable images and radiation doses. a. Radiation dose decreased slightly because of decreased repeats due to motion artifacts. 4. Limitations. a. Demand placed on the X-Ray tube. b. Image reconstruction takes ...
The benefits of Combined PET/CT and PET/MRI
The benefits of Combined PET/CT and PET/MRI

... powerful diagnostictool, particularly in the field of oncology (7).Thus, PET andCT have already proven to be ideal partners. ...
01_Overview - Wellcome Trust Centre for Neuroimaging
01_Overview - Wellcome Trust Centre for Neuroimaging

...  A frequency gradient persisting for a certain time establishes a sinusoidal phase gradient  The overall signal is stronger if the spatial frequency of the object (e.g. some cortical folds) matches this  Can effectively measure the 2D Fourier transform or spectrum of an object, and hence reconstr ...
Slide 1
Slide 1

...  Many have small molecular weights relative to the biological molecules they may be used to label (e.g., F) even if they aren’t found there naturally.  PET isotopes can be attached to biologically interesting molecules with no or minimal impact on the behaviour of those molecules in the body. ...
Welcome New PET Center of Excellence Board Members! Vice
Welcome New PET Center of Excellence Board Members! Vice

... of the next generation digital PET/CT system (Vereos), and under his direction the Imaging Core Laboratory at the Wright Center has been involved in a large portfolio of clinical PET trials, including the Oncology Biomarker Qualifying Initiative (OBQI). He has been a mentor to a large number of resi ...
The Department of Radiology is in the process of planning the
The Department of Radiology is in the process of planning the

... enables fields of view (FOV) up to 50 cm with minimum distortion. The gradients and gradient amplifiers are water cooled, and can be run at 100% duty cycle, with all three gradients on at full strength (2000 V and 625 A on each axis). Hardware methods to reduce acoustic noise are used to reduce acou ...
Dental CT scanners and physical quality parameters El
Dental CT scanners and physical quality parameters El

... Materials and methods: In this work, two dental CBCT units; namely: Scanora 3D and 3D Accuitomo 80 were assessed and compared in terms of quantitative effective dose delivered to specific locations in a dosimetry phantom. Resolution and contrast were evaluated in only 3D Accuitomo 80 using special q ...
AbstractID: 10105 Title: Managing the Imaging Dose during Image-Guided Radiation Therapy
AbstractID: 10105 Title: Managing the Imaging Dose during Image-Guided Radiation Therapy

... Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Today, image-guided radiotherapy (IGRT) can involve 3DCT for treatment planning, fluoroscopy and 4DCT for pre-treatment motion assessment, daily in-r ...
Nuclear imaging1
Nuclear imaging1

... detector systems may well be the detectors of the future as with modern technology, large arrays of such detectors can be produced. If the detectors are arranged in ringdetector banks, cross-sectional images can be obtained, and if several rings adjacent to each other are used, data acquisition is t ...
Advanced Ultrasound Imaging
Advanced Ultrasound Imaging

...  Sound beam steered to set of predetermined angles, typically within 20 ...
Introduction to Medical Imaging
Introduction to Medical Imaging

... • Uses x-rays, but exposure is limited to a slice (or “a couple of” slices) by a collimator • Source and detector rotate around object – projections from many angles • The desired image, I(x,y) = m(x,y,z0), is computed from the projections ...
< 1 ... 88 89 90 91 92 93 94 95 96 ... 99 >

Positron emission tomography



Positron emission tomography (PET) is a nuclear medicine, functional imaging technique that produces a three-dimensional image of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule. Three-dimensional images of tracer concentration within the body are then constructed by computer analysis. In modern PET-CT scanners, three dimensional imaging is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine.If the biologically active molecule chosen for PET is fluorodeoxyglucose (FDG), an analogue of glucose, the concentrations of tracer imaged will indicate tissue metabolic activity as it corresponds to the regional glucose uptake. Use of this tracer to explore the possibility of cancer metastasis (i.e., spreading to other sites) is the most common type of PET scan in standard medical care (90% of current scans). However, on a minority basis, many other radioactive tracers are used in PET to image the tissue concentration of other types of molecules of interest. One of the disadvantages of PET scanners is their operating cost.
  • studyres.com © 2025