Laboratory Manual - Mohawk Valley Community College
... signal analysis. For equipment, each lab station should include a dual adjustable DC power supply, a dual trace oscilloscope, a function generator and a quality DMM. Some exercises also make use of a distortion analyzer and a low distortion generator (generally, THD below 0.01%), although these port ...
... signal analysis. For equipment, each lab station should include a dual adjustable DC power supply, a dual trace oscilloscope, a function generator and a quality DMM. Some exercises also make use of a distortion analyzer and a low distortion generator (generally, THD below 0.01%), although these port ...
Chapter 9 - La Sierra University
... Capacitor types Variable Variable capacitors typically have small capacitance values and are usually adjusted manually. A solid-state device that is used as a variable capacitor is the varactor diode; it is adjusted with an electrical signal. ...
... Capacitor types Variable Variable capacitors typically have small capacitance values and are usually adjusted manually. A solid-state device that is used as a variable capacitor is the varactor diode; it is adjusted with an electrical signal. ...
V - Physics | Oregon State University
... Damping time or "1/e" time is t = 1/b > 1/w0 (>> 1/w0 if b is very small) How many T0 periods elapse in the damping time? This number (times π) is the Quality factor or Q of the system. ...
... Damping time or "1/e" time is t = 1/b > 1/w0 (>> 1/w0 if b is very small) How many T0 periods elapse in the damping time? This number (times π) is the Quality factor or Q of the system. ...
Laboratory Manuals
... To measure a voltage, connect the nodes over which one wants to measure the voltage between the HI and LO input terminals of the DMM (Figure 3). In order to activate the DMM for DC measurements you have to select the DC Voltage function by pushing the DC V button on the front panel (see Figure 3). T ...
... To measure a voltage, connect the nodes over which one wants to measure the voltage between the HI and LO input terminals of the DMM (Figure 3). In order to activate the DMM for DC measurements you have to select the DC Voltage function by pushing the DC V button on the front panel (see Figure 3). T ...
ISL6539 Datasheet
... an input through a resistor divider tracking to VDDQ/2. The PG2/REF pin becomes the output of the VDDQ/2 buffered voltage. The VDDQ/2 voltage is also used as the reference to the error amplifier by the second channel. The channel phase-shift synchronization is determined by the VIN pin when DDR = 1 ...
... an input through a resistor divider tracking to VDDQ/2. The PG2/REF pin becomes the output of the VDDQ/2 buffered voltage. The VDDQ/2 voltage is also used as the reference to the error amplifier by the second channel. The channel phase-shift synchronization is determined by the VIN pin when DDR = 1 ...
MAX5037A VRM 9.0/VRM 9.1, Dual-Phase, Parallelable, Average-Current-Mode Controller General Description
... with a minimum number of external components. The MAX5037A utilizes a dual-phase, average-current-mode control that enables optimal use of low R DS(ON) MOSFETs, eliminating the need for external heatsinks even when delivering high output currents. Differential sensing enables accurate control of the ...
... with a minimum number of external components. The MAX5037A utilizes a dual-phase, average-current-mode control that enables optimal use of low R DS(ON) MOSFETs, eliminating the need for external heatsinks even when delivering high output currents. Differential sensing enables accurate control of the ...
LTC3606B - Linear Technology
... The input supply voltage range is 2.5V to 5.5V, making it ideal for Li-Ion and USB powered applications. 100% duty cycle capability provides low dropout operation, extending the run time in battery-operated systems. Low output voltages are supported with the 0.6V feedback reference voltage. The LTC3 ...
... The input supply voltage range is 2.5V to 5.5V, making it ideal for Li-Ion and USB powered applications. 100% duty cycle capability provides low dropout operation, extending the run time in battery-operated systems. Low output voltages are supported with the 0.6V feedback reference voltage. The LTC3 ...
OKL2-T/20-W12 Series
... (11) Other input or output voltage ranges will be reviewed under scheduled quantity special order. (12) Maximum PC board temperature is measured with the sensor in the center of the converter. (13) Do not exceed maximum power specifications when adjusting the output trim. (14) The maximum output capa ...
... (11) Other input or output voltage ranges will be reviewed under scheduled quantity special order. (12) Maximum PC board temperature is measured with the sensor in the center of the converter. (13) Do not exceed maximum power specifications when adjusting the output trim. (14) The maximum output capa ...
Topics: Parallel circuits, current sources
... B.05 Demonstrate an understanding of application of Ohm’s Law to series, parallel, and series-parallel circuits. Partially met – parallel circuits only. B.11 Understand principles and operations of DC parallel circuits. B.12 Fabricate and demonstrate DC parallel circuits. B.13 Troubleshoot and repai ...
... B.05 Demonstrate an understanding of application of Ohm’s Law to series, parallel, and series-parallel circuits. Partially met – parallel circuits only. B.11 Understand principles and operations of DC parallel circuits. B.12 Fabricate and demonstrate DC parallel circuits. B.13 Troubleshoot and repai ...
High efficiency step-down controller with embedded 2 A LDO regulator
... Frequency selection. Connect to the central tap of a resistor divider to set the desired switching frequency. The pin cannot be left floating. See Section 7: Device description on page 19 for details. ...
... Frequency selection. Connect to the central tap of a resistor divider to set the desired switching frequency. The pin cannot be left floating. See Section 7: Device description on page 19 for details. ...
VCA820 Wideband, > 40-dB Adjust Range, Linear in dB Variable
... VCA820 adjusts the gain linearly in dB as the control voltage varies from 0 V to +2 V. For example, set for a maximum gain of +10 V/V, the VCA820 provides 20 dB, at +2-V input, to –20 dB at 0-V input of gain control range. The VCA820 offers excellent gain linearity. For a 20-dB maximum gain, and a g ...
... VCA820 adjusts the gain linearly in dB as the control voltage varies from 0 V to +2 V. For example, set for a maximum gain of +10 V/V, the VCA820 provides 20 dB, at +2-V input, to –20 dB at 0-V input of gain control range. The VCA820 offers excellent gain linearity. For a 20-dB maximum gain, and a g ...
Atmel MSL3080 8 String 60mA LED Drivers with Integrated Boost Controller FULL DATASHEET
... of LED power. The MSL3080 has eight current sinks. Parallel connect the current sinks for increased string current. A single resistor sets LED current, with string matching and accuracy within ±3%. The advanced integrated PWM circuitry allows up to 4095:1 dimming, and offers simple PWM dimming contr ...
... of LED power. The MSL3080 has eight current sinks. Parallel connect the current sinks for increased string current. A single resistor sets LED current, with string matching and accuracy within ±3%. The advanced integrated PWM circuitry allows up to 4095:1 dimming, and offers simple PWM dimming contr ...
4 Requirements - European Cooperation for Space Standardization
... ability to function satisfactorily in its electromagnetic environment without introducing intolerable electromagnetic disturbances to anything in that environment. The space system is designed to be compatible with its external natural, induced, or man-made electromagnetic environment. Natural compo ...
... ability to function satisfactorily in its electromagnetic environment without introducing intolerable electromagnetic disturbances to anything in that environment. The space system is designed to be compatible with its external natural, induced, or man-made electromagnetic environment. Natural compo ...
Test probe