Evaluates: MAX4104/MAX4105/MAX4304/MAX4305 MAX4104 Evaluation Kit ________________General Description ____________________________Features
... 2) Connect the output marked OUT to an oscilloscope through a terminated 50Ω cable. 3) Turn on the power supply. Apply a signal of ±3.4V maximum to the SMA connector marked IN. 4) Verify the output signal on the oscilloscope. Note: when using a 50Ω terminated oscilloscope input, the output amplitude ...
... 2) Connect the output marked OUT to an oscilloscope through a terminated 50Ω cable. 3) Turn on the power supply. Apply a signal of ±3.4V maximum to the SMA connector marked IN. 4) Verify the output signal on the oscilloscope. Note: when using a 50Ω terminated oscilloscope input, the output amplitude ...
User`s Guide True RMS Multimeter Extech 430
... WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. 1. ALWAYS turn the function switch to the OFF position when the meter is not in use. 2. If “OL” appears in the display during a measurement, the value exceeds the range y ...
... WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. 1. ALWAYS turn the function switch to the OFF position when the meter is not in use. 2. If “OL” appears in the display during a measurement, the value exceeds the range y ...
Single Phase Series AC Circuits
... 1. An alternating voltage given by v = 100sin240t volts is applied across a coil of resistance 32Ω and inductance 100 mH. Determine (a) the circuit impedance, (b) the current flowing, (c) the p.d. across the resistance and (d) the p.d. across the inductance. (40Ω, 1.77A, 56.64v, 42.48v) 2. A coil of ...
... 1. An alternating voltage given by v = 100sin240t volts is applied across a coil of resistance 32Ω and inductance 100 mH. Determine (a) the circuit impedance, (b) the current flowing, (c) the p.d. across the resistance and (d) the p.d. across the inductance. (40Ω, 1.77A, 56.64v, 42.48v) 2. A coil of ...
Resistance - Leaving Cert Physics
... If it reads zero then no current flows between the two points. We say that the bridge is balanced. Now the key to this is to realise that not only can the bridge be balanced when there is a current flowing on either side, but the currents on either side need not be the same, indeed it would be rare ...
... If it reads zero then no current flows between the two points. We say that the bridge is balanced. Now the key to this is to realise that not only can the bridge be balanced when there is a current flowing on either side, but the currents on either side need not be the same, indeed it would be rare ...
Resistance in series and parallel
... up the voltage until a voltage of approximately 5 V is indicated on the voltmeter. Observe the current on the ammeter. Record the measured voltage (which might be different from 5.00 V) and the measured current in the lab report. Open the switch when you are finished with these measurements. This wi ...
... up the voltage until a voltage of approximately 5 V is indicated on the voltmeter. Observe the current on the ammeter. Record the measured voltage (which might be different from 5.00 V) and the measured current in the lab report. Open the switch when you are finished with these measurements. This wi ...
Capacitor Self
... potential (if the outlet is wired correctly!). This is an important safety feature since the case is the part of an instrument you are most likely to touch. Consequently, if you mistakenly connect the ground clip to a high voltage, or there is an internal instrument failure that shorts a high voltag ...
... potential (if the outlet is wired correctly!). This is an important safety feature since the case is the part of an instrument you are most likely to touch. Consequently, if you mistakenly connect the ground clip to a high voltage, or there is an internal instrument failure that shorts a high voltag ...
LM6172 Dual High Speed, Low Power, Low Distortion, Voltage
... Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is intended to be functional, but specific performance is not guaranteed. For guaranteed specifications and the test conditions, see the Electrical ...
... Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is intended to be functional, but specific performance is not guaranteed. For guaranteed specifications and the test conditions, see the Electrical ...
Measuring Voltage and Current
... • Any instrument (meter) used to make measurements extracts energy from the circuit. (Known as “loading” the circuit). • The amount of error due to loading depends on the effective resistance of the instrument compared with the resistance in the circuit. ...
... • Any instrument (meter) used to make measurements extracts energy from the circuit. (Known as “loading” the circuit). • The amount of error due to loading depends on the effective resistance of the instrument compared with the resistance in the circuit. ...
MAT04 Data Sheet
... The circuit of Figure 6 is a very low noise, high speed amplifier, ideal for use in precision transducer and professional audio applications. The performance of the amplifier is summarized in Table I. Figure 7 shows the input referred spot noise over the 0–25 kHz bandwidth to be flat at 1.2 nV/√Hz. ...
... The circuit of Figure 6 is a very low noise, high speed amplifier, ideal for use in precision transducer and professional audio applications. The performance of the amplifier is summarized in Table I. Figure 7 shows the input referred spot noise over the 0–25 kHz bandwidth to be flat at 1.2 nV/√Hz. ...
Trade-off between EMI Separator and D. Sakulhirirak , V. Tarateeraseth
... neutral voltage signal, respectively. CS is a parasitic capacitance caused by MOSFET (Q ) between drain and frame ground via its heat-sink. ...
... neutral voltage signal, respectively. CS is a parasitic capacitance caused by MOSFET (Q ) between drain and frame ground via its heat-sink. ...
ad515a data sheet
... capability of the ultralow input currents of the AD515A. Guarding is achieved by applying a low impedance bootstrap potential to the outside of the insulation material surrounding the high impedance signal line. This bootstrap potential is held at the same level as that of the high impedance line; t ...
... capability of the ultralow input currents of the AD515A. Guarding is achieved by applying a low impedance bootstrap potential to the outside of the insulation material surrounding the high impedance signal line. This bootstrap potential is held at the same level as that of the high impedance line; t ...
Test probe