Complete ECE 112 Manual
... turned off, use only one hand when working on it. This will prevent a circuit from being going through your heart, which could be potentially fatal. ...
... turned off, use only one hand when working on it. This will prevent a circuit from being going through your heart, which could be potentially fatal. ...
chapter06
... Figure 6.11 Current flows from the power line through the body and ground impedance, thus creating a common-mode voltage everywhere on the body. Zin is not only resistive but, as a result of RF bypass capacitors at the amplifier input, has a reactive component as well. © From J. G. Webster (ed.), Me ...
... Figure 6.11 Current flows from the power line through the body and ground impedance, thus creating a common-mode voltage everywhere on the body. Zin is not only resistive but, as a result of RF bypass capacitors at the amplifier input, has a reactive component as well. © From J. G. Webster (ed.), Me ...
electrical measurement laboratory
... 3. Mix all the resistors together and select, at random, any 12 resistors. Your selection may or may not include resistors from the previous sample. Measure and record the values of the 12 resistors in Table 1.1 (Sample 2). ...
... 3. Mix all the resistors together and select, at random, any 12 resistors. Your selection may or may not include resistors from the previous sample. Measure and record the values of the 12 resistors in Table 1.1 (Sample 2). ...
TPS70302 数据资料 dataSheet 下载
... For each regulator, there is an internal discharge transistor to discharge the output capacitor when the regulator is turned off (disabled). The PG1 pin reports the voltage condition at VOUT1. The PG1 pin can be used to implement an SVS (POR, or power-on reset) for the circuitry supplied by regulato ...
... For each regulator, there is an internal discharge transistor to discharge the output capacitor when the regulator is turned off (disabled). The PG1 pin reports the voltage condition at VOUT1. The PG1 pin can be used to implement an SVS (POR, or power-on reset) for the circuitry supplied by regulato ...
Multi-Output Power Supplies with VCOM Amplifier MAX17126/MAX17126A General Description
... for thin-film transistor liquid-crystal display (TFT LCD) TV panels operating from a regulated 12V input. They include a step-down and a step-up regulator, a positive and a negative charge pump, an operational amplifier, a high-accuracy high-voltage gamma reference, and a high-voltage switch control ...
... for thin-film transistor liquid-crystal display (TFT LCD) TV panels operating from a regulated 12V input. They include a step-down and a step-up regulator, a positive and a negative charge pump, an operational amplifier, a high-accuracy high-voltage gamma reference, and a high-voltage switch control ...
AAT4614 数据资料DataSheet下载
... The AAT4614 is a single channel current limiting load switch that is intended to protect against short circuit and over current events by current limiting to a preset level. This device also provides a reverse current blocking feature, on / off enable control, and a fault flag to notify a system con ...
... The AAT4614 is a single channel current limiting load switch that is intended to protect against short circuit and over current events by current limiting to a preset level. This device also provides a reverse current blocking feature, on / off enable control, and a fault flag to notify a system con ...
Application Note No. 060
... (f2-f1) is. Therefore as input test tones f1 and f2 come closer together, more capacitance is needed to achieve best possible bypassing of the low frequency product (f2-f1). For a test tone separation of 1 MHz, 0.1 µF was found to be more than adequate in this particular application circuit. A good ...
... (f2-f1) is. Therefore as input test tones f1 and f2 come closer together, more capacitance is needed to achieve best possible bypassing of the low frequency product (f2-f1). For a test tone separation of 1 MHz, 0.1 µF was found to be more than adequate in this particular application circuit. A good ...
Current mode multiple-valued logic circuits in digital
... using binary logic is reaching a point where most of the silicon area is occupied with interconnecting lines among devices on the chip, which represents a drawback of the approach. First implication of the high wiring complexity is increased packing complexity with increased number of pins (in today ...
... using binary logic is reaching a point where most of the silicon area is occupied with interconnecting lines among devices on the chip, which represents a drawback of the approach. First implication of the high wiring complexity is increased packing complexity with increased number of pins (in today ...
AN3119
... providing for the reduction of the mains harmonics, allowing the European EN61000-3-2 or the Japanese JEITA-MITI standard to be met. The regulated output voltage is typically the input for the cascaded isolated DC-DC converter which provides the output rails required by the load. The power stage of ...
... providing for the reduction of the mains harmonics, allowing the European EN61000-3-2 or the Japanese JEITA-MITI standard to be met. The regulated output voltage is typically the input for the cascaded isolated DC-DC converter which provides the output rails required by the load. The power stage of ...
MAX14838/9 - Maxim Part Number Search
... LDO..........................................................................-0.3V to +6V DO............................................................Higher of (VCC - 36V) and -36V Lower of (VCC + 36V) and +36V DIN, NPN, PP, NO, LDO2IN, FAULT........................-0.3V to +6V LEDS, LED2........ ...
... LDO..........................................................................-0.3V to +6V DO............................................................Higher of (VCC - 36V) and -36V Lower of (VCC + 36V) and +36V DIN, NPN, PP, NO, LDO2IN, FAULT........................-0.3V to +6V LEDS, LED2........ ...
MAX13051 ±80V Fault-Protected Can Transceiver with Autobaud General Description
... of wires should connect each element of the CAN bus, and the two ends of the bus should be terminated with 120Ω resistors, see Figure 6. A star configuration should never be used. Any deviation from the point-to-point wiring scheme creates a stub. The high-speed edge of the CAN data on a stub can cr ...
... of wires should connect each element of the CAN bus, and the two ends of the bus should be terminated with 120Ω resistors, see Figure 6. A star configuration should never be used. Any deviation from the point-to-point wiring scheme creates a stub. The high-speed edge of the CAN data on a stub can cr ...
AD7482 数据手册DataSheet下载
... operation. A falling edge on this pin resets the internal state machine and terminates a conversion that may be in progress. The contents of the offset register are also cleared on this edge. Holding this pin low keeps the part in a reset state. Operating Mode Logic Input. See Table 8 for details. O ...
... operation. A falling edge on this pin resets the internal state machine and terminates a conversion that may be in progress. The contents of the offset register are also cleared on this edge. Holding this pin low keeps the part in a reset state. Operating Mode Logic Input. See Table 8 for details. O ...
A MATLAB/GUI BASED FAULT SIMULATION TOOL FOR POWER
... most of the tedious and repetitive calculations in the background, allowing the user to spend more time in the analysis of the results obtained. Many power system analysis applications have been developed taking advantage of GUI [2]. In this study, a MATLAB/GUI (Graphical User Interface) based simul ...
... most of the tedious and repetitive calculations in the background, allowing the user to spend more time in the analysis of the results obtained. Many power system analysis applications have been developed taking advantage of GUI [2]. In this study, a MATLAB/GUI (Graphical User Interface) based simul ...
22B-QS001G-EN-P PowerFlex 40 Adjustable Frequency AC Drive
... intended for qualified drive service personnel only. For detailed PowerFlex 40 information including EMC instructions, application considerations and related precautions, refer to the PowerFlex 40 User Manual, Publication 22B-UM001… at www.rockwellautomation.com/literature. ...