74HC423 - Nexperia
... The 74HC423 is a dual retriggerable monostable multivibrator with output pulse width control by two methods. The basic pulse time is programmed by selection of an external resistor (REXT) and capacitor (CEXT). Once triggered, the basic output pulse width may be extended by retriggering (nA) or (nB). ...
... The 74HC423 is a dual retriggerable monostable multivibrator with output pulse width control by two methods. The basic pulse time is programmed by selection of an external resistor (REXT) and capacitor (CEXT). Once triggered, the basic output pulse width may be extended by retriggering (nA) or (nB). ...
BM1Q001FJ
... terminal is too large, response of the VCC pin to the Secondary output is slows down. Please be careful. If the degree of the transformer coupling is low, since a large surge occurs to the VCC pin, the IC may be destroyed. In this case, please attach a resistor which is from 10Ω to 100Ω to the path ...
... terminal is too large, response of the VCC pin to the Secondary output is slows down. Please be careful. If the degree of the transformer coupling is low, since a large surge occurs to the VCC pin, the IC may be destroyed. In this case, please attach a resistor which is from 10Ω to 100Ω to the path ...
AN2299
... special conditions and the results are impossible to reproduce in other locations, where there may be a different measuring set-up. Also short time repeatability due to noise and the resulting statistical effects will be bigger. The external influences on total system accuracy can be as big as or ev ...
... special conditions and the results are impossible to reproduce in other locations, where there may be a different measuring set-up. Also short time repeatability due to noise and the resulting statistical effects will be bigger. The external influences on total system accuracy can be as big as or ev ...
Bates
... Fig. 2-17: Rheostat connected in series circuit to vary the current I. Symbol for the current meter is A, for amperes. (a) Wiring diagram with digital meter for I. (b) Schematic diagram. Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. ...
... Fig. 2-17: Rheostat connected in series circuit to vary the current I. Symbol for the current meter is A, for amperes. (a) Wiring diagram with digital meter for I. (b) Schematic diagram. Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. ...
ARTECHE SMART GRID
... Integrated into ARTECHE SMART GRID, the Auxiliary Relays Business Head Office and Factory is located in Bilbao, Spain, where a team of 90 professionals works to help you in the quickest and most flexible way. • More than 50 years experience in the manufacture of auxiliary relays for high responsibil ...
... Integrated into ARTECHE SMART GRID, the Auxiliary Relays Business Head Office and Factory is located in Bilbao, Spain, where a team of 90 professionals works to help you in the quickest and most flexible way. • More than 50 years experience in the manufacture of auxiliary relays for high responsibil ...
LT4363 - High Voltage Surge Stopper with Current Limit
... device is in an overcurrent condition (current fault). The internal NPN is capable of sinking up to 2mA of current. GATE: N-Channel MOSFET Gate Drive Output. The GATE pin is pulled up by an internal charge pump current source to 13V above the OUT pin. A 14V protection clamp limits this voltage durin ...
... device is in an overcurrent condition (current fault). The internal NPN is capable of sinking up to 2mA of current. GATE: N-Channel MOSFET Gate Drive Output. The GATE pin is pulled up by an internal charge pump current source to 13V above the OUT pin. A 14V protection clamp limits this voltage durin ...
LT3650-4.1/LT3650-4.2 - High Voltage 2 Amp Monolithic Li
... For no RRNG/SS, this capacitor value follows the relation: CRNG/SS = 50µA • tSS The RNG/SS pin is pulled low during fault conditions, allowing graceful recovery from faults should soft-start functionality be implemented. Both the soft-start capacitor and the programming resistor can be implemented ...
... For no RRNG/SS, this capacitor value follows the relation: CRNG/SS = 50µA • tSS The RNG/SS pin is pulled low during fault conditions, allowing graceful recovery from faults should soft-start functionality be implemented. Both the soft-start capacitor and the programming resistor can be implemented ...
AD9714 数据手册DataSheet 下载
... converters are optimized for the transmit signal path of communication systems. All the devices share the same interface, package, and pinout, providing an upward or downward component selection path based on performance, resolution, and cost. ...
... converters are optimized for the transmit signal path of communication systems. All the devices share the same interface, package, and pinout, providing an upward or downward component selection path based on performance, resolution, and cost. ...
Fast digital calibration procedure for STPM01 based energy meters
... special conditions and the results are impossible to reproduce in other locations, where there may be a different measuring set-up. Also short time repeatability due to noise and the resulting statistical effects will be bigger. The external influences on total system accuracy can be as big as or ev ...
... special conditions and the results are impossible to reproduce in other locations, where there may be a different measuring set-up. Also short time repeatability due to noise and the resulting statistical effects will be bigger. The external influences on total system accuracy can be as big as or ev ...
Analog Electronics Primer
... have zero potential. Thus, ground (or earth) is the reference point to which voltages are most often compared. Many electrical appliances in your home are grounded. This is especially true of air conditioning units, electric clothes dryers, and washing machines. Often this is done by connecting a he ...
... have zero potential. Thus, ground (or earth) is the reference point to which voltages are most often compared. Many electrical appliances in your home are grounded. This is especially true of air conditioning units, electric clothes dryers, and washing machines. Often this is done by connecting a he ...
MAX19791 50MHz to 4000MHz Dual Analog Voltage Variable
... DAC can be used to control both attenuators. In addition, a step-up/down feature allows user-programmable attenuator stepping through command pulses without reprogramming the SPI interface. The MAX19791 is a monolithic device designed using one of Maxim’s proprietary SiGe BiCMOS processes. The part ...
... DAC can be used to control both attenuators. In addition, a step-up/down feature allows user-programmable attenuator stepping through command pulses without reprogramming the SPI interface. The MAX19791 is a monolithic device designed using one of Maxim’s proprietary SiGe BiCMOS processes. The part ...
Valve RF amplifier
A valve RF amplifier (UK and Aus.) or tube amplifier (U.S.), is a device for electrically amplifying the power of an electrical radio frequency signal.Low to medium power valve amplifiers for frequencies below the microwaves were largely replaced by solid state amplifiers during the 1960s and 1970s, initially for receivers and low power stages of transmitters, transmitter output stages switching to transistors somewhat later. Specially constructed valves are still in use for very high power transmitters, although rarely in new designs.