DS2746 Low-Cost 2-Wire Battery Monitor with Ratiometric A/D Inputs GENERAL DESCRIPTION
									
... Units: 1LSB = VVOUT * 1/2047 ...
                        	... Units: 1LSB = VVOUT * 1/2047 ...
									NEC-403 - ABES Engineering College
									
... - due to unknown causes, occur when all systematic error has accounted - accumulation of small effect, require at high degree of accuracy - can be avoid by (a) increasing number of reading (b) use statistical means to obtain best approximation of true value ...
                        	... - due to unknown causes, occur when all systematic error has accounted - accumulation of small effect, require at high degree of accuracy - can be avoid by (a) increasing number of reading (b) use statistical means to obtain best approximation of true value ...
									Si9185 Micropower 500 mA CMOS LDO Regulator with Error Flag
									
... well as tantalum, output capacitors. An external noise bypass capacitor connected to the device’s CNOISE pin will lower the LDO’s output noise for low noise applications. The Si9185 also includes an out-of-regulation error flag. If a capacitor is connected to the device’s delay pin, the error flag o ...
                        	... well as tantalum, output capacitors. An external noise bypass capacitor connected to the device’s CNOISE pin will lower the LDO’s output noise for low noise applications. The Si9185 also includes an out-of-regulation error flag. If a capacitor is connected to the device’s delay pin, the error flag o ...
									Current, Voltage, Impedance • Ohm`s Law, Kirchhoff`s Laws • Circuit
									
... positive terminal of the voltage source. ...
                        	... positive terminal of the voltage source. ...
									Testing Ethernet Ports including Power Over Ethernet (802.3at and
									
... impulse of 2.1 kV. Criteria “c” (2.4 kV) ports will withstand a longitudinal impulse of 2.4 kV, Annex C. Current multi-pair standards testing use a 1.5 kV impulse and hence fail to verify competent port design. There are cases where cheap transformer manufacturers don’t do a 1500 Vrms “hipot” insula ...
                        	... impulse of 2.1 kV. Criteria “c” (2.4 kV) ports will withstand a longitudinal impulse of 2.4 kV, Annex C. Current multi-pair standards testing use a 1.5 kV impulse and hence fail to verify competent port design. There are cases where cheap transformer manufacturers don’t do a 1500 Vrms “hipot” insula ...
									Heathkit HM-102 - Orange County (California) Amateur Radio Club
									
... and a solder lug, followed by the front panel controls and meter. The other end of the five-wire cable from the remote sensor chassis assembly is attached to the cabinet using a cable clamp. The cabinet wiring involves wiring up the fivewire cable, the controls and the meter. Three 0.001 µf and one ...
                        	... and a solder lug, followed by the front panel controls and meter. The other end of the five-wire cable from the remote sensor chassis assembly is attached to the cabinet using a cable clamp. The cabinet wiring involves wiring up the fivewire cable, the controls and the meter. Three 0.001 µf and one ...
									R eq
									
... They will draw more current, because they are connected in parallel. There are now two different, but identical paths for electricity to flow, so the current doubles! ...
                        	... They will draw more current, because they are connected in parallel. There are now two different, but identical paths for electricity to flow, so the current doubles! ...
									Physics 6B - UCSB CLAS
									
... The next step is to combine the remaining resistors, which are in series. The formula is simple – just add them together. 20V ...
                        	... The next step is to combine the remaining resistors, which are in series. The formula is simple – just add them together. 20V ...
									I=1 A
									
... The charge ends up where it started, so the total energy lost must equal the initial potential energy input: ...
                        	... The charge ends up where it started, so the total energy lost must equal the initial potential energy input: ...
									FPF2200-FPF2202 Integrated Load Switch with 500mA High Precision Current Limit FP F2
									
... Upon the detection of an over-current condition, an input UVLO, or an over-temperature condition, the FLAGB signals the fault mode by activating LO. In the event of an over-current condition for the FPF2200 and FPF2201, the FLAGB goes LO at the end of the blanking time while FLAGB goes LO immediatel ...
                        	... Upon the detection of an over-current condition, an input UVLO, or an over-temperature condition, the FLAGB signals the fault mode by activating LO. In the event of an over-current condition for the FPF2200 and FPF2201, the FLAGB goes LO at the end of the blanking time while FLAGB goes LO immediatel ...
									Document
									
... consider the circuit. Which of the following is/are not true? R2 R1 1. If R2=R3=2R1 the potential drops over R1 and R2 are the same I V 2. for any value of R1,R2 and R3 the potential drop over R1 must be equal to the potential drop over R2 3. The current through R1 is equal to the current through R2 ...
                        	... consider the circuit. Which of the following is/are not true? R2 R1 1. If R2=R3=2R1 the potential drops over R1 and R2 are the same I V 2. for any value of R1,R2 and R3 the potential drop over R1 must be equal to the potential drop over R2 3. The current through R1 is equal to the current through R2 ...
									T5A01 Electrical current is measured in which of
									
... T5C09 How much power is being used in a circuit when the applied voltage is 13.8 volts DC and the current is 10 amperes? A. B. C. D. ...
                        	... T5C09 How much power is being used in a circuit when the applied voltage is 13.8 volts DC and the current is 10 amperes? A. B. C. D. ...
									Per-Unit - Iowa State University
									
... Normally, in power systems, power bases are specified as kVA or MVA. One must always ensure these values are converted to units of VA before using the above formula (1 kVA=1x10 3 VA, 1 MVA=1x106 VA). Likewise, voltage bases are usually specified as kV. One must always ensure these values are convert ...
                        	... Normally, in power systems, power bases are specified as kVA or MVA. One must always ensure these values are converted to units of VA before using the above formula (1 kVA=1x10 3 VA, 1 MVA=1x106 VA). Likewise, voltage bases are usually specified as kV. One must always ensure these values are convert ...
									Using Two-Point Modulation To Reduce Synthesizer Problems
									
... The PLL frequency synthesizer presents a unique problem when designing an effective GMSK modulator. Data patterns consisting of long strings of ones or zeros have a spectral response that extends to DC. Most frequency synthesizers do not respond to this low-frequency signal because of their inherent ...
                        	... The PLL frequency synthesizer presents a unique problem when designing an effective GMSK modulator. Data patterns consisting of long strings of ones or zeros have a spectral response that extends to DC. Most frequency synthesizers do not respond to this low-frequency signal because of their inherent ...
Valve RF amplifier
                        A valve RF amplifier (UK and Aus.) or tube amplifier (U.S.), is a device for electrically amplifying the power of an electrical radio frequency signal.Low to medium power valve amplifiers for frequencies below the microwaves were largely replaced by solid state amplifiers during the 1960s and 1970s, initially for receivers and low power stages of transmitters, transmitter output stages switching to transistors somewhat later. Specially constructed valves are still in use for very high power transmitters, although rarely in new designs.