• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Autotransformers - ELHAND Transformatory
Autotransformers - ELHAND Transformatory

... The I3 current in the common part of the autotransformer winding is small as compared with I1 and I2 currents. Thus, the cross-section of this part of the winding may be decreased, bringing about considerable savings. Using smaller quantities of iron and copper for building the machine results in sm ...
BR26452459
BR26452459

... There are severe power-quality problems, such as poor voltage regulation, high reactive power and harmonics current burden, load unbalancing excessive neutral current, etc now-a-days distribution systems are facing. The source voltage in the distribution systems are also experiencing PQ problems, su ...
Alberta Reliability Standard – BES Cyber System Categorization Cyber Security CIP-002-AB-5.1
Alberta Reliability Standard – BES Cyber System Categorization Cyber Security CIP-002-AB-5.1

... commissioned generation, by each group of generating units or aggregated generating facilities at a single plant location, with an aggregate maximum authorized real power rating of each of the generating units minus the station service load equal to or exceeding 1500 MW in a single Interconnection. ...
unit 3 - WordPress.com
unit 3 - WordPress.com

... order to insulate and to bring out the terminals of the winding from the tank, apt bushings that are made from either porcelain or capacitor type must be used. In all transformers that are used commercially, the core is made out of sheet steel laminations assembled to provide a continuous magnetic p ...
2012 Standard For Air-Conditioning, Heating And Refrigerating
2012 Standard For Air-Conditioning, Heating And Refrigerating

... Notes: 1) It is recommended that in any one country, the ratio between two adjacent nominal voltages should be not less than two. 2) In a normal system, the highest voltage and the lowest voltage do not differ by more than approximately ±10% from the nominal voltage of the system. 3) These values sh ...
34 Electric Current
34 Electric Current

... always flows in one direction. • A battery produces direct current in a circuit because the terminals of the battery always have the same sign of charge. • Electrons always move through the circuit from the negative terminal toward the positive terminal. • Even if the current moves in unsteady pulse ...
Alberta Reliability Standard Cyber Security – BES Cyber System Categorization CIP-002-AB-5.1
Alberta Reliability Standard Cyber Security – BES Cyber System Categorization CIP-002-AB-5.1

... commissioned generation, by each group of generating units or aggregated generating facilities at a single plant location, with an aggregate highest rated net maximum authorized real power capabilityrating of each of the preceding 12 monthsgenerating units minus the station service load equal to or ...
Voltage Stability Analysis of Radial Distribution Networks with
Voltage Stability Analysis of Radial Distribution Networks with

... well recognized in distribution systems. Radial distribution systems having a high resistance to reactance ratio causes a high power loss so that the radial distribution system is one of the power systems, which may suffer from voltage instability [1, 3]. In certain industrial areas, it has been obs ...
issue - IET Electrical
issue - IET Electrical

... Regulation 551.2 to ensure the safe ...
Transformer
Transformer

... • To maximize power transfer, the load resistance must be matched with the source resistance • Normally, the two resistance are not matched and fixed (e.g.: speaker’s resistance (source) is only a few ohms, but internal resistance of audio power amplifier (load) is several thousand ohms. To connect ...
T5 Basic Electricity Questions
T5 Basic Electricity Questions

... SUBELEMENT T5 [4 Exam Questions - 4 Groups] Electrical Principles, Electronic Principles, Math for Electronics ...
Alberta Reliability Standard – BES Cyber System Categorization Cyber Security CIP-002-AB-5.1
Alberta Reliability Standard – BES Cyber System Categorization Cyber Security CIP-002-AB-5.1

... 2.10. each system or group of element(s) that performs automatic load shedding under a common control system, without human operator initiation, of 300 MW or more implementing under voltage load shed or underfrequency load shedding under a load shedding program that is subject to one or more require ...
step-up transformer
step-up transformer

... 1. Primary coil – the incoming voltage Vp (voltage across primary coil) is connected across this coil. 2. Secondary coil – this provides the output voltage Vs (voltage across the secondary coil) to the external circuit. 3. Laminated iron core – this links the two coils magnetically. Notice that ther ...
Unit C 7-5 - Edhole.com
Unit C 7-5 - Edhole.com

... single-phase current, the voltage rises to a peak in one direction of flow, subsides to zero, reverses, rises to a peak in the opposite direction, subsides to zero, and so on. ...
Unit C 7-5
Unit C 7-5

... single-phase current, the voltage rises to a peak in one direction of flow, subsides to zero, reverses, rises to a peak in the opposite direction, subsides to zero, and so on. ...
Transformers, Harmonic Currents and Phase Shifting
Transformers, Harmonic Currents and Phase Shifting

... Power measurements were taken while a 75kVA low Z transformer was installed to supply the two panels. These readings are shown in Table 1 (next page). This transformer was replaced with another one with the same power rating whose primary winding was deltaconnected and whose secondary winding was do ...
2014 Over 600Volts SW Section.pptx
2014 Over 600Volts SW Section.pptx

... •  Rules  cover  supply  and  communica2on  lines,  equipment,  and   associated  work  prac2ces  employed  by  a  public  u2lity  or   private  electric  supply,  communica2ons,  railway,  or  similar   u2lity  in  the  exercise  or  func2on ...
"SCR (Silicon-Controlled Rectifier) Dimming Technology in LED
"SCR (Silicon-Controlled Rectifier) Dimming Technology in LED

... uneven, fluctuate or even have spikes, affecting VRMS. This situation will not affect the incandescent light since incandescent light is a linear load with operating current, usually over 50mA. However, in case of LED lighting, the uneven output waveform will become a flickering issue. ...
1C.4.1—Harmonic Distortion
1C.4.1—Harmonic Distortion

... Harmonic distortion is commonly produced by customer equipment injecting electrical noise into the power system. This will degrade PacifiCorp’s service to other customers. Maintaining electrical noise within tolerable limits will allow PacifiCorp to provide quality electrical service to all its cust ...
2. Technical Aspects of Grid Interconnection
2. Technical Aspects of Grid Interconnection

... power system interconnection is a kind of marriage, because two systems become one in an important way when they operate in synchronism. To do this requires a high degree of technical compatibility and operational coordination, which grows in cost and complexity with the scale and inherent differenc ...
EE 1332833
EE 1332833

... multiples of the fundamental frequency(50Hz). These higher frequencies are a form of electrical pollution known as power system harmonics. Transformers are the major components in power systems and increased harmonic distortion can cause excessive winding losses and hence abnormal temperature rise. ...
Islamic University of Gaza Faculty of Engineering Electrical
Islamic University of Gaza Faculty of Engineering Electrical

... primary side of the transformer may be connected in delta like in the figure, or in wye. One big advantage of using a delta configuration for the primary is that only three wires are needed to distribute the three phases. ...
CLASS NOTE LECTURE-1 Introduction Development of technology
CLASS NOTE LECTURE-1 Introduction Development of technology

... Transients:Transients are short duration power system phenomena. They show very high rise of voltage and current in short period of time. Power system transients may generate in the system itself or may propagate to the system from other external system. Transients are treated as one major disturban ...
high voltage direct current power transmission
high voltage direct current power transmission

... for lines and cables, and an analysis must be made for each individual case. The importance of the break-even-distance concept should not be over-stressed, since several other factors, such as controllability, are important in the selection between AC or HVDC power transmission. In general, a DC lin ...
Neutral Grounding
Neutral Grounding

... designed to limit the line-to-ground fault current to below 15 amps for generators rated up to 14,400 volts. These units will provide a high resistance neutral during a fault condition, while allowing the system to operate as an ungrounded system during normal operating conditions. The configuration ...
< 1 ... 9 10 11 12 13 14 15 16 17 ... 50 >

War of the currents

  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report