• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a

... unit or an aggregated generating facility, including those in a power plant or an industrial complex; or (b) the reactive power to be achieved by the generating unit, aggregated generating facility, power plant or industrial complex. R6 The ISO must monitor the status of all transmission reactive po ...
PDF
PDF

AB34169175
AB34169175

Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a

Development of a Rotary Transformer and Its Application to SRC
Development of a Rotary Transformer and Its Application to SRC

Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a

... R8 The ISO, when notified by the operator of a generating unit of the loss of automatic voltage regulator control, or by the operator of an aggregated generating facility of the loss of voltage regulating system control, must issue a directive or instruction to the operator to maintain or change eit ...
student identification number (sin)
student identification number (sin)

PUB-NP-279 Q. Describe Newfoundland Power’s protective relaying criteria (standard design
PUB-NP-279 Q. Describe Newfoundland Power’s protective relaying criteria (standard design

... entering an electrical node must exactly equal the amount of electricity leaving the node. For substation buses, if this rule fails because the electricity flow on transmission lines into the substation bus does not match the electricity flow through to the distribution feeders then it is assumed th ...
LK3519521955
LK3519521955

ATC Determination for Different Transactions Using ACPTDF
ATC Determination for Different Transactions Using ACPTDF

1 Introduction
1 Introduction

... (instead of DTO or ITO), parameter settings are affected by the infeed effect [6]. The determined impedance is changed due to current input along the protected line. This may shift the selective tripping schedule and selectivity may not be achieved. A re-setting of the distance relay parameters is n ...
EE 1090510
EE 1090510

Aalborg Universitet transmission systems for passive networks
Aalborg Universitet transmission systems for passive networks

The Simulation Study and Dynamic Analysis of Unified Power Flow
The Simulation Study and Dynamic Analysis of Unified Power Flow

... simulation UPFC acts as a STATCOM. Therefore this is the STATCOM mode of operation. V1ref=1 pu. Load injected at t=0.15 sec. and rejected at t= 0.35 sec. As seen in Fig. 7. bus 1 voltage decreases and it approximately has value of 0.98 pu when P+jQ inductive load injected at t=0.15. Decreased bus 1 ...
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER

Optimal Placement of Unified Power Flow Controller for
Optimal Placement of Unified Power Flow Controller for

... As the demand for electrical energy is continuously increasing, it necessitates the expansion of the transmission network along with the installation of new power plants. But at the same time, such projects are getting delayed or even blocked due to many factors such as cost and environmental consid ...
Three - Phase Electric Power Distribution
Three - Phase Electric Power Distribution

Recommending a Strategy
Recommending a Strategy

... It could strike quickly (they move at millions of miles per hour) with rises times of less than a minute, rapidly covering a good chunk of the continent Reactive power loadings on hundreds of transformers could sky rocket, causing heating issues and potential ...
Direct Current Electric and Magnetic Fields
Direct Current Electric and Magnetic Fields

... What work has been done to monitor DC electric and magnetic fields for Bipoles I and II? Bipoles I and II have been operating in Manitoba since the 1970s. The Manitoba HVDC Research Centre, Manitoba Hydro and the National Research Council of Canada conducted a long-term monitoring of the electric fi ...
transmission planning criteria
transmission planning criteria

... tested in each Capability Period so that they can automatically switch fuel from natural gas to liquid fuel whenever experiencing low system gas pressure or a loss of gas condition. Automatic switching shall occur at any dispatch level within 45 seconds of experiencing low gas pressure. The generato ...
Comparison of Voltage Stability by Using Various Fact
Comparison of Voltage Stability by Using Various Fact

... International Journal of Engineering Science and Computing, April 2016 ...
FI3110651072
FI3110651072

... ABSTRACT Now a days electrical power consumption has been increased and increasing drastically. So it must be supplied to all the consumers with high reliability and quality. Since the load is unpredicted but only estimated the generation must be equal to load all the times. But due to variations in ...
Voltage leval improment by using Static VAR compensator (SVC)
Voltage leval improment by using Static VAR compensator (SVC)

Merchant Generation Site Selection On the AEP Transmission System - January 2010-revised
Merchant Generation Site Selection On the AEP Transmission System - January 2010-revised

Transmission System Supply Reliability and Quality Regulation
Transmission System Supply Reliability and Quality Regulation

< 1 ... 15 16 17 18 19 20 21 22 23 ... 35 >

Electric power transmission



Electric power transmission is the bulk transfer of electrical energy, from generating power plants to electrical substations located near demand centers. This is distinct from the local wiring between high-voltage substations and customers, which is typically referred to as electric power distribution. Transmission lines, when interconnected with each other, become transmission networks. The combined transmission and distribution network is known as the ""power grid"" in North America, or just ""the grid"". In the United Kingdom, the network is known as the ""National Grid"".A wide area synchronous grid, also known as an ""interconnection"" in North America, directly connects a large number of generators delivering AC power with the same relative frequency, to a large number of consumers. For example, there are four major interconnections in North America (the Western Interconnection, the Eastern Interconnection, the Quebec Interconnection and the Electric Reliability Council of Texas (ERCOT) grid), and one large grid for most of continental Europe.The same relative frequency, but almost never the same relative phase as ac power interchange is a function of the phase difference between any two nodes in the network, and zero degrees difference means no power is interchanged; any phase difference up to 90 degrees is stable by the ""equal area criteria""; any phase difference above 90 degrees is absolutely unstable; the interchange partners are responsible for maintaining frequency as close to the utility frequency as is practical, and the phase differences between any two nodes significantly less than 90 degrees; should 90 degrees be exceeded, a system separation is executed, and remains separated until the trouble has been corrected.Historically, transmission and distribution lines were owned by the same company, but starting in the 1990s, many countries have liberalized the regulation of the electricity market in ways that have led to the separation of the electricity transmission business from the distribution business.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report