
AD7414
... As system load increases, power dissipation increases, temperature increase, fans speeds increase, acoustics increases Closed Loop Control ensures that you are operating at the lowest possible acoustics, while providing a safe operating environment. ...
... As system load increases, power dissipation increases, temperature increase, fans speeds increase, acoustics increases Closed Loop Control ensures that you are operating at the lowest possible acoustics, while providing a safe operating environment. ...
Types of DR Island Systems - IEEE Standards working groups
... load sharing; dispatch within the island; generation shedding; energy storage; seamless transfer vs shutdown and resync; stability (single and multigens); synchronous, inverter, induction based machines; grounding and neutrals; power quality (transitions, …); system protection (including surge prote ...
... load sharing; dispatch within the island; generation shedding; energy storage; seamless transfer vs shutdown and resync; stability (single and multigens); synchronous, inverter, induction based machines; grounding and neutrals; power quality (transitions, …); system protection (including surge prote ...
INDUSTRIAL ELECTRICITY/ELECTRONICS TECHNOLOGY (ILT)
... This course provides a study of instrumentation circuits/systems. Topics include the use of transducers, detectors, actuators, and/or other devices and equipment in industrial applications. Upon completion, the student should be able to apply principles of instrumentation circuits and systems. ILT 1 ...
... This course provides a study of instrumentation circuits/systems. Topics include the use of transducers, detectors, actuators, and/or other devices and equipment in industrial applications. Upon completion, the student should be able to apply principles of instrumentation circuits and systems. ILT 1 ...
723PLUS Digital Control
... Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be correct and reliable. However, no responsibility is assumed by Woodward unless otherwise expressly ...
... Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be correct and reliable. However, no responsibility is assumed by Woodward unless otherwise expressly ...
(BIL) ratings for medium-voltage controllers
... specifies the required dielectric-withstand voltage values for the controllers. For controllers rated over 3.6 kV up to 7.2 kV, UL 347 specifies that the lightning-impulse withstand voltage should be either 45 kV or 60 kV. For controllers rated 1,500 V to 3,600 V, UL 347 specifies values of 30 kV or ...
... specifies the required dielectric-withstand voltage values for the controllers. For controllers rated over 3.6 kV up to 7.2 kV, UL 347 specifies that the lightning-impulse withstand voltage should be either 45 kV or 60 kV. For controllers rated 1,500 V to 3,600 V, UL 347 specifies values of 30 kV or ...
A Current-Control Strategy for Voltage
... harmonic frequencies of interest. The internal model is infinitedimensional and can be obtained by connecting a delay line into a feedback loop. Such a closed-loop system can deal with a very large number of harmonics simultaneously. It has been successfully applied to constant-voltage constant-freq ...
... harmonic frequencies of interest. The internal model is infinitedimensional and can be obtained by connecting a delay line into a feedback loop. Such a closed-loop system can deal with a very large number of harmonics simultaneously. It has been successfully applied to constant-voltage constant-freq ...
Mini-SAM II Layout - Simon
... and microphone inputs are also provided. Eight optically isolated trigger inputs, 16 direct output controls, and DMX-512 in/out for additional control are all included. The on-board real-time clock facilitates event triggering. Programming the MS-2 is simple with a PC and the FREE (with purchase of ...
... and microphone inputs are also provided. Eight optically isolated trigger inputs, 16 direct output controls, and DMX-512 in/out for additional control are all included. The on-board real-time clock facilitates event triggering. Programming the MS-2 is simple with a PC and the FREE (with purchase of ...
WellPilot® Controllers for Rod Pump Optimization
... The brains behind every WellPilot rod-pump control system. The powerful WellPilot RPC gathers data from the well through surface load and position sensors and uses the MEJ calculation engine to calculate downhole data to determine pump fillage and fluid level for each stroke. In fixed-speed applicat ...
... The brains behind every WellPilot rod-pump control system. The powerful WellPilot RPC gathers data from the well through surface load and position sensors and uses the MEJ calculation engine to calculate downhole data to determine pump fillage and fluid level for each stroke. In fixed-speed applicat ...
Distributed control system
A distributed control system (DCS) is a control system for a process or plant, wherein control elements are distributed throughout the system. This is in contrast to non-distributed systems, which use a single controller at a central location. In a DCS, a hierarchy of controllers is connected by communications networks for command and monitoring.Example scenarios where a DCS might be used include: Chemical plants Petrochemical (oil) and refineries Boiler controls and power plant systems Nuclear power plants Environmental control systems Water management systems Metallurgical process plants Pharmaceutical manufacturing Sugar refining plants Dry cargo and bulk oil carrier ships Formation control of multi-agent systems