• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
electrical power system
electrical power system

... Note that the Power Generator>>Charger>>Battery>>Electronic equipment system provides uninterruptible power even if the generator goes off (e.g. for refuelling). However, if you use the DC feed available on some generators to charge the heavy duty batteries, ensure you do not run the generator in an ...
Motor start-up
Motor start-up

LTC-7PN
LTC-7PN

... Keeper® is a registered trademark of ...
Zen Variations 8
Zen Variations 8

... designers linearize the tube circuit by operating the voltage/current load line so as to get some cancellation between competing voltage and current distortion. This can be done with either single-ended or push-pull circuits. The guys with pentode type devices, which includes solid state as well as ...
Lab 1 - UniMAP Portal
Lab 1 - UniMAP Portal

... magnetic field. Ferromagnetic cores are commonly used to provide tight magnetic coupling and high flux densities. Single-phase transformers are widely used in low power electronic or control circuits to isolate one circuit from another. They are also used as instrument transformers to measure voltag ...
a general review of photovoltaic inverter and mppt
a general review of photovoltaic inverter and mppt

... and similar devices use to get the large possible power from one or more photovoltaic platrs, typically solar panels, though optical power transmission systems can improve efficiency from similar technology. Solar cells have a complex relationship between solar irradiation, temperature and total res ...
Test systems for -compliance
Test systems for -compliance

... Standards concerning the electromagnetic compatibility of a product classify the permissible degree of electromagnetic interference emission as well as immunity to it. Two different types of electromagnetic interference emissions that affect the public power system are considered: current harmonics ...
Coherent Integrates Marway`s Power Distribution Solution into New
Coherent Integrates Marway`s Power Distribution Solution into New

MOTOR BOARD
MOTOR BOARD

... - Dual-channel encoder for direct acquisition of speed and direction of rotation - Built-in sight window for optical recognition of speed and direction of rotation and stroboscopic scanning A DC power amplifier is built into the MOTOR BOARD for direct connection to a controller or a PLL circuit. It ...
Achieve 20-30% power savings in low-power
Achieve 20-30% power savings in low-power

... The TPS62730 is a high- frequency synchronous step-down DC/DC converter optimized for ultra-low-power wireless applications such as TI’s low-power wireless sub 1-GHz and 2.4-GHZ RF transceivers. The device reduces the current consumption drawn from the battery during TX and RX mode by a high-efficie ...
3-Terminal Positive Regulators
3-Terminal Positive Regulators

... positive voltage regulators employ internal current-limiting, thermal shutdown and safe-area compensation, making them essentially indestructible. If adequate heat sinking is provided, they can deliver over 1.0A output current. They are intended as fixed voltage regulators in a wide range of applica ...
50 KW DGCA - West Generator Services
50 KW DGCA - West Generator Services

... Several alternators are available for application flexibility based on the required motor-starting kVA and other requirements. Larger alternator sizes have lower temperature rise for longer life of the alternator insulation system. In addition, larger alternator sizes can provide a cost-effective us ...
Electrostatic Treater Performance Enhancements
Electrostatic Treater Performance Enhancements

K580HC-K975A - Avtron Froment
K580HC-K975A - Avtron Froment

Electrical Safe Working Practices
Electrical Safe Working Practices

Transformers Practice #1
Transformers Practice #1

- Emicro Technologies
- Emicro Technologies

B-138 Series, Rated up to 60 Amps, 115/200 VAC, 400... HARTMAN Power Switching AC Contactors Product Facts
B-138 Series, Rated up to 60 Amps, 115/200 VAC, 400... HARTMAN Power Switching AC Contactors Product Facts

... Contact Arrangement — TPST NO and TPDT NC Rated Operating Voltage — 115/200 VAC, 400 Hz, 3 phase Current, Resistive — 60 Amps Current, Inductive — 60 Amps Current, Motor — 60 Amps Current, Rupture — 600 Amps ...
ER Week11, Other Sources, Photoresistor
ER Week11, Other Sources, Photoresistor

...  Electricity and Electronics, Section 5.2, Other Sources of Electrical Energy: o Electrical Energy from Light:  Two forms of solar energy conversion:  Solar thermal, that is, thermal systems (hot water, pool heaters) produce heat from the sun’s radiation at 40% efficiency.  Photovoltaic (photo = ...
Synchronous generators
Synchronous generators

... In the majority of the synchronous generators, a sinusoidal voltage is induced in the stator by driving a rotor. This rotor produces, with respect to this rotor, a fixed magnetic field. This fixed magnetic field is due to permanent magnets mounted in the rotor or this magnetic field is due to electr ...
Thrifty: An Exascale Architecture for Energy
Thrifty: An Exascale Architecture for Energy

... Josep Torrellas (University of Illinois), Daniel Quinlan (Lawrence Livermore National Laboratory), Laura Carrington (University of California, San Diego), Wilfred Pinfold (Intel) http://extremescale.cs.illinois.edu/thrifty March 2013 This work proposes a novel exascale architecture called Thrifty. T ...
LECTURER-26 GENERATION OF IMPULSE CURRENTS Lightning
LECTURER-26 GENERATION OF IMPULSE CURRENTS Lightning

... representing the nominal wave front and wave tail times the tolerances allowed on these times are ±10%only. Apart from the standard impulse current, waves, rectangular waves of long duration are also used for testing. The waveshape should be nominally rectangular in shape. The rectangular waves gene ...
EES612-Lab-1 Single - Department of Electrical and Computer
EES612-Lab-1 Single - Department of Electrical and Computer

... Transformers are widely applied in many electrical systems, small or large. A few of their most tangible areas of application include long-distance, bulk power transmission systems, medical and consumer electronic devices for level shifting and galvanic isolation, audio, video, and radio systems for ...
Circuits with Troubleshooting
Circuits with Troubleshooting

... contact points running the length of the board. These lines are often color-coded red (+) or blue (-), and are called bus lines. Use one of the lines (red if available) for all connections to power supply (+), and another line (blue if available) for all connections to power supply (-). If the circu ...
Merit Series - Oakwood Broadcast
Merit Series - Oakwood Broadcast

... brightness to just the right level. The M-8D adds a bright red, three-digit LED meter that displays incoming voltage. The M-8 and M-10 are designed for applications where lights are not required. M-Series conditioners protect your delicate electronic equipment by combining high voltage varistor (MOV ...
< 1 ... 870 871 872 873 874 875 876 877 878 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report