• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AN-1002 Reverse Current Blocking with Silego GreenFET Load
AN-1002 Reverse Current Blocking with Silego GreenFET Load

2N4416 2N4416A SST4416 JFET
2N4416 2N4416A SST4416 JFET

MX Series data sheet - AMETEK Programmable Power
MX Series data sheet - AMETEK Programmable Power

LA4500
LA4500

Experiment # 1: pn junction diode and zener diode
Experiment # 1: pn junction diode and zener diode

... Aim: To construct Half wave, Full wave and Bridge Rectifier circuits using diodes study the regulation with various filter circuits. Equipment & components required: Step down transformer with centre tap (12-012V) or (9-0-9V), C.R.O., diodes, capacitor and resistors, regulator chips (IC 7809 and IC ...
Faults Simulation Trainer in Electrical Motors ESAM www.edibon.com
Faults Simulation Trainer in Electrical Motors ESAM www.edibon.com

... Technical Teaching Equipment ...
CF25485491
CF25485491

... industrial and commercial power systems require several studies to assist in the evaluation of the initial and future system performance, system reliability, safety, and the ability to grow with production and/or operating requirements. The studies most likely to be needed are load flow studies, cab ...
design and implementation of power factor correction (pfc)
design and implementation of power factor correction (pfc)

... frequency, fci, in order to maintain adequate phase margin. A graphical design of the loop compensator by bode diagram, is shown in Figure 2. The first diagram in Figure 2 shows the gain diagram for all of the control blocks in the current loop, or in other words, the Gid, Fm and Ks, except the curr ...
Full Article
Full Article

... good results and post late removal will make the machine to absorb more reactive power from the grid so, an automatic Crowbar protection is been employed which automatically works according to the requirement. The combined protection and control strategy is being proposed in the simulation results. ...
Implementation of Control Center Based Voltage and Var
Implementation of Control Center Based Voltage and Var

XMT® 304CC/CV
XMT® 304CC/CV

... Designed for use with dual wire feeders, applications where electrical isolation and/or polarity reversing of weld current is required, and for welding process changes. Includes 115 VAC/2-amp receptacle, two 14-pin receptacles and a 10-foot (3 m) 14-pin cord. RFCS-14 Foot Control ...
Design , Implementation and Testing of SPWM Inverter on dSPACE
Design , Implementation and Testing of SPWM Inverter on dSPACE

... Abstract: SPV based system mostly requires an inverter to deliver ac power at the consumers end. This paper presents development of a prototype of a three-phase bridge inverter for SPV applications using dSPACE 1104 hardware Real Time interface with Matlab/Simulink software. Real time Simulation env ...
DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

... Power Supply Rejection Ratio(Referred to the Output) vs Frequency ...
Low Voltage System Configuration
Low Voltage System Configuration

... • Remote programability/monitoring: Voltage, current limits, ramping rates, voltage and current monitoring (10 nA resolution). • Isolation: power supply outputs must be floating. Furthermore, since one set of plus and minus outputs supply current for up to 10 trays tray inputs are isolated from othe ...
Alternating Current - Goodheart
Alternating Current - Goodheart

... Another value of an ac wave you should recognize is its peak-to-peak value. Study Figure 13-7 and note these values. The peak-to-peak value of a waveform always appears on an oscilloscope, which is one of the basic instruments used in observing and measuring ac waves. The oscilloscope, generally ref ...
WORLD ENERGY COUNCIL
WORLD ENERGY COUNCIL

Most Common Errors in Service Entrance and Load Side Install
Most Common Errors in Service Entrance and Load Side Install

... Disadvantages: 1. It is also susceptible to ferroresonance *, especially during 1ø sequential switching when energized in series with cable capacitance to ground. 2. The bank cannot be parallel with D-D or Y-Y banks because of the phase difference of 30 degrees between line voltages of the banks on ...
204.74 kB - World Energy Council
204.74 kB - World Energy Council

... Electrical apparatus for switching or protecting electrical circuits or for making connections to or in electrical circuits, for a voltage exceeding 1 kV ...
VIEW PowerPoint Presentiation
VIEW PowerPoint Presentiation

... Once a thyristor is in a conduction mode, the gate circuit has no control and the device will continue to conduct. Also, the forward voltage drop is very small, often between 0.5V and 2V. ...
Boost converter Operation - San Jose State University
Boost converter Operation - San Jose State University

... San José State University College of Engineering/Electrical Engineering EE174: Analog Peripheral for Embedded Systems Section 01, Fall 2016 ...
SPS-5 and SPS-10 Technical Sales Bulletin
SPS-5 and SPS-10 Technical Sales Bulletin

... connected together. When J1 & J2 are cut, you must supply 11 to 27.5Vdc to Control power, then you may connect any voltage to 32V AC or DC to the Main Power Terminals. See Dual/Separate Power application figure below. Inputs (1-8 IN C) Eight, two position un-pluggable terminal blocks. When IN & C ar ...
Design and Implementation of Automatic Three Phase Changer
Design and Implementation of Automatic Three Phase Changer

... However, most companies; Industrial, commercial and even domestic are dependent on public power supply which have erratic supply such as phase failure, phase imbalances or total power failure due to one or more technical problem in power generation, transmission or distribution [2]. Hence, there is ...
PART 2 – PRODUCTS MANUFACTURERS Manufacturers: Subject
PART 2 – PRODUCTS MANUFACTURERS Manufacturers: Subject

doc - Purdue College of Engineering
doc - Purdue College of Engineering

... battery and input through an ATD pin. It will be important to use very high value resistors as to not draw too much current away from powering the motor. While there are more elegant and efficient means of implementing a charge monitoring circuit, this alternative provides the simplest solution. Als ...
amprobe at-1000
amprobe at-1000

< 1 ... 731 732 733 734 735 736 737 738 739 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report