• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Interharmonics - Working Group
Interharmonics - Working Group

... indicates that these lamps produce visible light flicker even when there is no significant change in the overall RMS value of the waveform as shown in Figure 7. This is due to the changes in peak voltage over time due to the intermodulation of the harmonic and interharmonic components. This is evide ...
Study of Cellphone Chargers
Study of Cellphone Chargers

... Apple ,Nokia, Samsung, Sony , icube and two local make chargers. We also charged a cellphone through the USB port of the Laptop. ...
Eaton 9390 UPS
Eaton 9390 UPS

... With this optional cabinet, Eaton offers a complete, one-stop shop for power protection and distribution solutions that is easy to design, install, customize and manage – while delivering pay-as-yougrow scalability for future expansion. ...
DSL  Primary Switched Battery Charging and Power Supply Unit GL0524
DSL Primary Switched Battery Charging and Power Supply Unit GL0524

... batteries and/or for supplying 24V DC circuits. The charging unit is especially suitable for use with diesel generators, where operating safety and long-term stability are necessary. The primary clocked switching power supply with 100kHz technology is intended for use on the top-hat rail due to its ...
A New Energy Recovery Circuit for the Capacitive Load using the
A New Energy Recovery Circuit for the Capacitive Load using the

... interest toward developing a high luminance and high luminous efficiency mercury-free flat light sources has gained momentum [2]-[7]. It is also modeled as an equivalent panel capacitance (CP). When the sustain voltage (VS), which is the AC square wave with a high peak-to-peak value, is applied to t ...
3A Linear Regulator Can Be Easily Paralleled to Spread Power and
3A Linear Regulator Can Be Easily Paralleled to Spread Power and

... The LT3083’s deceptively simple architecture and high performance parameters make it powerful building block for applications beyond the basic linear regulator. It can be easily paralleled to increase output current and spread heat. Actively driving the SET pin is perfectly acceptable; the low offse ...
3155 Integrated Amplifier - hifi
3155 Integrated Amplifier - hifi

OPERATING 60 CYCLE INDUCTION MOTORS AS GENERATORS
OPERATING 60 CYCLE INDUCTION MOTORS AS GENERATORS

... STEP 3- With no loads of any kind connected to the generator, its voltage should build-up (usually a faint generator hum is audible). If you are using a Single-phase machine, be sure it is turning the same direction that it turned as a motor. Build up can be checked by momentarily connecting a light ...
Slide 1
Slide 1

Power Electronics Solution to Dust Emissions from
Power Electronics Solution to Dust Emissions from

... electrofilters remove flying ashes and fine particles from the flue gas before passing the gas into the chimney. Maximum allowable value of dust is 50 mg/m3 and it requires that the efficiency of the ESPs better than 99 %, which calls for an increase of active surface of the electrodes, hence increa ...
A High-Voltage Bidirectional Current Source
A High-Voltage Bidirectional Current Source

... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
Review
Review

... When on, current can flow only in the direction of the arrow Instantaneous switching from one state to the other Conduct large current with zero voltage drop in on-state Block large forward and reverse voltages with zero current flow when off • Infinite voltage and current handling capabilities Copy ...
Motors and Generators #2
Motors and Generators #2

Electrical Circuit Ananlysis - Jordan University of Science and
Electrical Circuit Ananlysis - Jordan University of Science and

... First Exam Second Exam Final Exam ...
ipe question bank - E
ipe question bank - E

estimation of voltage ratio, vector - e
estimation of voltage ratio, vector - e

... : 28kVrms : 3kVrms : 60 (at 50 % load) : 360 (at 100 % load) ...
Considerations in Designing Power Supplies for Particle Accelerators
Considerations in Designing Power Supplies for Particle Accelerators

... output and input voltage. On the other hand, switching technology produces a significant reduction in size and weight of the PSs and allows a reduction of heat sinks and magnetic parts compared to the linear technology. Therefore efficiency of the SMPSs is typically higher. PS efficiency affects dir ...
SiP Power Modules White Paper
SiP Power Modules White Paper

... published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a l ...
Topology, design, analysis and thermal management applications
Topology, design, analysis and thermal management applications

... achieve high voltages with low harmonics, and produce minimum electromagnetic interference or common-mode voltage. Different methods can be used to construct multilevel converters. One example is to use a cascaded connection, as shown in Figure 11. The advantage of such a configuration is the abilit ...
HANDOUK SG RELAY Features Input: DC control Double SCR AC
HANDOUK SG RELAY Features Input: DC control Double SCR AC

... 2. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. 3. The input circuitry does not incorporate a circuit protecting the SSR from being damaged due to a reversed connection. Make sur ...
SG RELAY Features Input: DC control Double SCR AC output or
SG RELAY Features Input: DC control Double SCR AC output or

... 2. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. 3. The input circuitry does not incorporate a circuit protecting the SSR from being damaged due to a reversed connection. Make sur ...
3 Connecting the ISA 3000
3 Connecting the ISA 3000

... Connect the PC to the Cisco ISA 3000 management sub-network which will then receive an IP address through DHCP. You can then launch ASDM to manage the device. ...
sinamics s What is your drive? Simply get started? SINAMICS GM150: The uncomplicated
sinamics s What is your drive? Simply get started? SINAMICS GM150: The uncomplicated

Document
Document

IOSR Journal of Dental and Medical Sciences (IOSR-JDMS)
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS)

... is a complex interconnected structure with generation, transmission and distribution sectors as its components. The power from generation system is connected to the distribution system through long transmitting lines. The quality of power has a direct economic and financial impact on both utilities ...
< 1 ... 720 721 722 723 724 725 726 727 728 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report