• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Aalborg Universitet Autonomous Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid
Aalborg Universitet Autonomous Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid

... dc/ac conversion) to the ac power distribution system. The distribution system may be the utility grid or the local grid formed by a cluster of DGs which is called microgrid. The main role of DG inverter is to adjust output voltage phase angle and amplitude in order to control the active and reactiv ...
L21a_4345_Sp02
L21a_4345_Sp02

... Current sources made by using active devices have come to be widely used in analog integrated circuits as Biasing elements and as load devices for amplifier stages The use of current sources in biasing can result in superior insensitivity of circuit performance to power supply variations and to te ...
ATTACHMENT D Solar PV Standard Plan - Simplified BCM 6807
ATTACHMENT D Solar PV Standard Plan - Simplified BCM 6807

... of 3 branch circuits, one PV module per inverter and with PV module ISC maximum of 10-A DC, installed on a roof of a one- or two-family dwelling or accessory structure. The photovoltaic system must interconnect to a single-phase AC service panel of 120/240 Vac with service panel bus bar rating of 22 ...
Distribution Network Capacitor Resonance – A Case
Distribution Network Capacitor Resonance – A Case

mx321 automatic voltage regulator (avr)
mx321 automatic voltage regulator (avr)

ISSCC 2014 / SESSION 5 / PROCESSORS / 5.6
ISSCC 2014 / SESSION 5 / PROCESSORS / 5.6

... or better packaging. (2) Static voltage margining: set the VRM output to be higher by some amount (guard band); this method costs significant additional power. (3) VR load-lining: the VRM supply is increased during periods of low processor activity to provide voltage headroom for potential supply dr ...
voltagesummary
voltagesummary

... Theory: 1. Two resistors are placed in a series circuit with a 1.5 V Battery. In a series circuit the total battery voltage gets split up among the individual resistors. If you add each of the individual voltages together it will always equal the total voltage of the battery. Example ...
sr 2-125 two-channel amplifier
sr 2-125 two-channel amplifier

... non buffered. The maximum number of amplifiers that can be looped together will depend on the output capability of your source component. The digital outputs are buffered and can support multiple amplifiers. Only one output can be used at a time. • Full array of input/output connectivity f ...
A Complementary GaAs (CGaAs TM) 32
A Complementary GaAs (CGaAs TM) 32

TEMPUS: SWITCHING OPERATIONS 1: Introduction In case an
TEMPUS: SWITCHING OPERATIONS 1: Introduction In case an

DMS-EB - Murata Power Solutions
DMS-EB - Murata Power Solutions

... holes on the DMS-EB provide access to the ¾-turn calibration potentiometer on DMS-30 meters and the 3-turn potentiometer on DMS-40 meters. The adjustment range of both pots is very narrow. See the applicable product data sheet for more information on each meter’s calibration potentiometers. 7. Input ...
Assemble Manual - DIY, audio, electronics
Assemble Manual - DIY, audio, electronics

... the board to prevent them from working loose. In case the board is subject to vibrations, the copper wire could break due to fatigue if not fixed properly. This is especially important for in-speaker mounted amplifiers and mobile (car) amplifiers. Temperature resistant glue should be used, as the to ...
CONNECTION AGREEMENT This Agreement is made at ______
CONNECTION AGREEMENT This Agreement is made at ______

... (5) The project of the M/s COMPANY shall not cause voltage and current harmonics on the Distribution system which exceed the limits specified in Institute of Electrical and Electronics Engineers (IEEE) standard 519. (6) Generating units located near load centre, shall be capable of operating at rate ...
Aalborg Universitet
Aalborg Universitet

... between the MGs. The influence of communication delay on the system stability can be also evaluated using this model. Block diagrams of the model are drawn to facilitate the analysis. The ultimate goal is to design an active stabilization loop in order to improve the stability of MG clusters at the ...
Chapter 36 Summary – Magnetism
Chapter 36 Summary – Magnetism

... Calculate the frequency and period of a basketball player that makes 25 shots in 60 seconds. A wave travels 10 m in 2 s. What is the wave velocity? Sound waves in air travel at about 330 m/s. Calculate the frequency of a 2.5 m sound wave. Calculate the period. What is the electric force between char ...
Chapter 4 Delta Wiring Topologies
Chapter 4 Delta Wiring Topologies

... Redrawing the connections and showing just what is connected at one of the 40° positions we get the delta circuit above. Now this only shows three of the nine storage capacitors. As the Rotor turns it is re-connected with another set of three freshly charged storage capacitors. This proposed circuit ...
EDS-G308 Hardware Installation Guide v2
EDS-G308 Hardware Installation Guide v2

... Alarm Contact The Moxa EtherDevice Switch has one Alarm Contact located on the top panel. For detailed instructions on how to connect the Alarm Contact power wires to the two middle contacts of the 6-contact terminal block connector, see the Wiring the Alarm Contact section on page 6. A typical scen ...
Info: not part of baseline
Info: not part of baseline

... PDs shall be capable of accepting power on either pairset and on both pairsets. The two pairsets are named Mode A and Mode B. In each four-wire connection, the two wires associated with a pair are at the same nominal average voltage. Figure 145–12 in conjunction with Table 145–18 illustrates the two ...
Vacuum Tube amplifier
Vacuum Tube amplifier

... down <1dB at ends 18.3dB 500Hz-100KHz down 3dB @ 92Hz -1.2dB, 20Hz-100KHz down <1dB at ends -0.5dB, 90Hz-100KHz down 3dB @ 20Hz ...
Question Bank Solutions
Question Bank Solutions

... What is meant by back emf? Explain its significance. Dec 2013,June 2013 Significance of Back E.M.F. It is seen in the generating action, that when a conductor cuts the lines of flux, e.m.f. gets induced in the conductor. The question is obvious that in a d.c. motor, after a motoring action, armature ...
3011800000610
3011800000610

... factor, ∆f is the frequency offset from the carrier, F is the noise factor, k is the Boltzmann’s constant, T is the temperature, Ps is the RF power produced by the VCO, fc is the Flicker noise corner frequency, vn is the common mode noise voltage and kLC is a constant that is a function of L and C o ...
Electrical Construction Technology
Electrical Construction Technology

Product data sheet 3RT1033-3AK60 CONTACTOR, AC-3 11 KW/400 V,
Product data sheet 3RT1033-3AK60 CONTACTOR, AC-3 11 KW/400 V,

NCP1076B Flyback Converter Evaluation Board User`s
NCP1076B Flyback Converter Evaluation Board User`s

E48074751
E48074751

... Multi-phase machines and drives is a topic of growing relevance in recent years, and it presents many challenging issues that still need further research. This is the case of multi-phase space vector pulse width modulation (SVPWM), which shows not only more space vectors than the standard three-phas ...
< 1 ... 508 509 510 511 512 513 514 515 516 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report