• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Thermoelectric Generators manual for class
Thermoelectric Generators manual for class

... geometry (A/L) and two junction temperatures Th and Tc. Inversely, the three material properties can ideally be expressed in terms of three among the four maximum parameters. It turned out that, the two parameters ( I max and  mp ) are essential and any one of Vmax and W max can be valid. In real ...
Simplified Weld Control Board Manual Table of Contents
Simplified Weld Control Board Manual Table of Contents

A.V.R. - Leroy Somer
A.V.R. - Leroy Somer

The PXS Series of proportional extra-small high
The PXS Series of proportional extra-small high

... The PXS Series of proportional extra-small high voltage power supplies has excellent load regulation characteristics, as well as superior temperature stability performance. The small size of the units, ease of control, and high stability, make the PXS Series optimal for handheld devices, portable e ...
SAT series Coil Analyzers
SAT series Coil Analyzers

160000-r/min, 2.7
160000-r/min, 2.7

AC Capacitors 1000-7000 VAC, Film Capacitors with Aluminum Foil
AC Capacitors 1000-7000 VAC, Film Capacitors with Aluminum Foil

... being wound together. If there are two smooth surfaces next to each other, oil will not penetrate between them. The film can be roughened as shown on one or both sides. There are processes to make film with a naturally roughened surface and processes that require a subsequent roughening step after f ...
ANN BASED DETECTION OF OS CONDITIONS IN POWER SYSTEM
ANN BASED DETECTION OF OS CONDITIONS IN POWER SYSTEM

... completed with the real world signals from digital recorders installed in substations. The latter may also be used for further testing of designed units. Having gathered the comprehensive base of simulation cases one has to elaborate the available data to extract needed information. It is good pract ...
$doc.title

Microcomputer Datasheets Important Notices TLCS
Microcomputer Datasheets Important Notices TLCS

... 1. INTVLTD Interrupt Request When interrupt generation is enabled in the voltage detection circuit, an INTVLTD interrupt request may be generated not only when the supply voltage falls to the detection voltage level, but also when it rises to the detection voltage level. In ICE mode of the In-Circui ...
Embedded Systems 9. Low Power Design
Embedded Systems 9. Low Power Design

... can be finished no later than their deadlines and the energy consumption is minimized?  YDS Algorithm from “A Scheduling Model for Reduce CPU Energy”, Frances Yao, Alan Demers, and Scott Shenker, FOCS ...
Application Note
Application Note

A Brain-Machine Interface using Dry-Contact, Low
A Brain-Machine Interface using Dry-Contact, Low

... closed eyes, which is a commonly reported finding. Second, eye blinks from left or right eyes were detected with electrodes place on the forehead. The sensors used in the system use MEMS-based, dry electrodes that create a good contact with the skin without requiring gel. This makes for a much more c ...
ha200 : Optoma USA : http://www2.optoma.com/us
ha200 : Optoma USA : http://www2.optoma.com/us

... levels are reduced, and contributes to a "grainy" sound that is particularly audible and quite irritating at low listening levels.Conversely, in Class-A operation the output device is never completely shut off, so there is no "turn on" or "turn off"" time requirement, per se. Hence, there are no iss ...
bq24707_25_26 Input Voltage DPM App Note
bq24707_25_26 Input Voltage DPM App Note

A Concise Guide to the Published Amplifier
A Concise Guide to the Published Amplifier

... elson Pass has over a half of a dozen patents covering audio inventions. He has also published a few dozen articles featuring power amplifier circuits, a couple in conjuction with other authors. Most of these publications concern power amplifier designs, but some are about preamplifier circuits, pho ...
INTRODUCING
INTRODUCING

... The PTMP represents a new level of functionality, reliability, and serviceability in very smart battery charging for critical 24 volt systems aboard work boats, military, commercial, and recreational craft. A menu of pre-programmed battery type charge profiles as well as custom settings option allow ...
A Novel 20Hz Power Injection Protection Scheme for Stator Ground
A Novel 20Hz Power Injection Protection Scheme for Stator Ground

... motor field is applied to bring it into synchronism with the generator. So there has not low frequency zone because excitation is not existed at the beginning of start-up. In SFC start, synchronous start and wound rotor induction motor start, excitation is required to provide full field at zero spee ...
High Efficiency Squirrel Cage Induction Machines
High Efficiency Squirrel Cage Induction Machines

... machine operating as motor. Besides the classical destination of the induction machine as motor this machine is more and more used in the latest period as generator in the conversion chain of wind or micro-hydro energy into electricity. The induction generator is increasingly preferred in case of re ...
Installation and Maintenance Sheet - IF 1405 Revision 1
Installation and Maintenance Sheet - IF 1405 Revision 1

Design and Analysis of Two-Stage Operational
Design and Analysis of Two-Stage Operational

IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)

... shutdown of the entire system. In order to mitigate power interruptions, this research proposes a scheme called “DYNAMIC VOLTAGE RESTORER (DVR)”. The proposed scheme is able to quickly recognize the voltage sag, swell, harmonic and transient condition, and it can correct the voltage by either boosti ...
Product note Medium and high voltage generators for
Product note Medium and high voltage generators for

... and the same foot design is suitable for all protection classes. The large terminal space has room for optional bus bars, PTs and CTs. The center bus bar arrangement enables easy cable connection. These factors not only help OEMs to minimize the number of genset base frames but also produce signific ...
isscc 2010 / session 16 / high-performance data
isscc 2010 / session 16 / high-performance data

... For the applications requiring medium-to-high resolution ADCs, the pipelined architecture is considered to be the most optimal structure in terms of power consumption and area. With range overlap and redundant bit at each pipelined stage, the sub-ADC can tolerate large comparator offsets, thereby, l ...
integrated mos gate drivers
integrated mos gate drivers

... capacity, on which it is obtained the negative turn-off voltage. There are some IC drivers which operate at floating potentials and which can be supplied with a single voltage. This performance is obtained using the so-called bootstrap technique. Fig.6.3 shows an implementation of this technique for ...
< 1 ... 500 501 502 503 504 505 506 507 508 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report