• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
STC04IE170HP
STC04IE170HP

... The STC04IE170HP is manufactured in Monolithic ESBT technology, aimed at providing the best performance in high frequency / high voltage applications. It is designed for use in gate driven based topologies. ...
AMP215_Switchgear_final_130813 - International Atomic Energy
AMP215_Switchgear_final_130813 - International Atomic Energy

... Visual inspection including cleaning should be performed periodically. Anomalies in terms of discoloration, cracking, swelling or “hot” smell are observable indicators for ageing. The document EPRI 1011223 “Ageing Identification and Assessment Checklist. Electrical Components” [2] provides guidance ...
AB21 Class A Amplifier Analog Lab Experiment - Hik
AB21 Class A Amplifier Analog Lab Experiment - Hik

... The class A amplifiers are the amplifiers which deliver maximum undistorted symmetrical output voltage swing to the low impedance load. Generally any system (like a stereo, radio or television) consists of several stages of amplification. When the signal passes through these stages, the power level ...
Variable- Voltage Techniques
Variable- Voltage Techniques

... By solving the this problem, we can obtain the optimal supply voltage assignment on static voltage scheduling ...
Products for marine applications Performance and reliability in
Products for marine applications Performance and reliability in

... Synchronous motors and generators High efficiency and robust construction make our synchronous motors and generators ideal for the marine industry. Motors range up to 50 000 kW and generators – now with a low voltage range – from 11 to 50 000 kVA. A high degree of standardization enables shorter del ...
Electricity Storage Technologies for Short Term Power System
Electricity Storage Technologies for Short Term Power System

... 4) Black start of HVDC The black start services in the Danish power system must be available for start up within 15 minutes and must be able to deliver continuous power for 8 hours. The total needs in Denmark are about 40 MW, which is today delivered primarily by gas turbines at central power plants ...
Basic Circuit Elements - New Age International
Basic Circuit Elements - New Age International

... greater accuracy the performance of various systems with the help of a simple but powerful tool known as circuit theory. In fact circuit theory has revolutionised the process of analysis in all branches of engineering be it Civil, Mechanical, Electronices or Computer engineering. It has been possibl ...
unit IV old - SriRajkumar
unit IV old - SriRajkumar

... adjustable number of period Δt = p/f. The number of cycles n counted during this interval is ...
WLTS Hand-Held Test Set
WLTS Hand-Held Test Set

... startup and commissioning. The WLTS will supply power only to the trip unit and display and not any other connected modules. ...
Electrical Services Audit - Gold Coast Hospital
Electrical Services Audit - Gold Coast Hospital

... which is non compliant and have not been available for approx 15 years. The disadvantages of the central battery system are that the cabling is fire rated and the system does not have central monitoring system which is available for single point systems and aids in maintenance. A further disadvantag ...
Aalborg Universitet
Aalborg Universitet

... However, stability issues may appear when VRs are changed. In order to ensure system stability, small signal analysis is usually applied in order to find proper control parameters [10], [20]–[23]. In [10], suitable VRs are calculated according to small signal analysis results for keeping stable oper ...
Power System Stabilizer (PSS) - Mitsubishi Electric Power Products
Power System Stabilizer (PSS) - Mitsubishi Electric Power Products

... Please read the instruction manual before installing or using the products. ...
2015-277
2015-277

... All these activities have received precious inputs from the in-flight lessons learned either from GOCE or the USGerman mission GRACE. Others activities were initiated to improve the technology of the Attitude and Orbit Control System (AOCS, e.g. tests on magnetic bearing reaction wheels and miniatur ...
LM109/LM309 5-Volt Regulator (Rev. A)
LM109/LM309 5-Volt Regulator (Rev. A)

... voltage is greater than 10V. The output will rise to within 2V of the unregulated input if the ground pin does not make contact, possibly damaging the load. The LM109 may also be damaged if a large output capacitor is charged up, then discharged through the internal clamp zener when the ground pin m ...
A Design Study of Dual-Stator Permanent Magnet Brushless DC Motor
A Design Study of Dual-Stator Permanent Magnet Brushless DC Motor

... stator and the inside magnets compose an outer-rotor BLDC; the outer stator and the outside magnets compose an inner-rotor BLDC; both of the motors share the same rotor core. Due to the series magnetic circuit structure of the DSBLDC, the inside and outside magnets are oriented in the same magnetiza ...
AC Sources - Operating 3.8.1  3.8  ELECTRICAL POWER SYSTEMS
AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS

... a. Two qualified circuits between the offsite transmission network and the onsite Class 1E AC Electrical Power Distribution System; and b. Four emergency diesel generators (EDGs) capable of supplying the onsite Class 1E power distribution subsystems. ...
FSEZ1016A Primary-Side-Regulation PWM Integrated Power MOSFET FSEZ10 16A
FSEZ1016A Primary-Side-Regulation PWM Integrated Power MOSFET FSEZ10 16A

... The output current estimator detects the peak value of the drain current by a peak detection circuit and calculates the output current by the inductor discharge time (tDIS) and switching period (tS). This output information is compared with the internal precise reference to generate error voltage (V ...
ZLDO330 • 3.3 VOLT ULTRA LOW DROPOUT REGULATOR
ZLDO330 • 3.3 VOLT ULTRA LOW DROPOUT REGULATOR

... Using a circuit such as Figure 1, the ZLDO330 can easily provide a 3.3V logic supply from an available 5V rail where most standard regulators could not guarantee correct operation. Although this approach is not particularly energy efficient, if the load taken at 3.3V is not too large, then the added ...
Bright ideas for LED applications
Bright ideas for LED applications

Typical Application Diagram
Typical Application Diagram

Energy Efficient Distribution Transformers
Energy Efficient Distribution Transformers

... • Efficiency performance will meet the NEMA Premium® guidelines; 30% lower losses than DOE 10 CFR Part 431/TP1 and (if applicable) CSA C802.2 standards; when measured under a linear load profile. Non-Linear Load K-Factor Transformers - HPS Synergy® & HPS SuperSynergy® Energy efficient K-factor tran ...
Zero-voltage switching for three-level capacitor clamping
Zero-voltage switching for three-level capacitor clamping

AN-9742 Device Selection Guide for Half-Bridge Welding Machine (IGBT & Diode) Summary
AN-9742 Device Selection Guide for Half-Bridge Welding Machine (IGBT & Diode) Summary

Component Selection in Electronic System Design
Component Selection in Electronic System Design

... under consideration meets all the functions desired by the application. An example could be whether a certain power supply IC meets the voltage and current requirements of the application. DC Electrical Characteristics The most important DC Electrical Characteristic of the device to be considered is ...
regulator,lt1083,lt1084,lt1085.pdf
regulator,lt1083,lt1084,lt1085.pdf

... regulators. The only circuit difference between using the LT1083 family and older regulators is that they require an output capacitor for stability. Stability The circuit design used in the LT1083 family requires the use of an output capacitor as part of the device frequency compensation. For all op ...
< 1 ... 379 380 381 382 383 384 385 386 387 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.