• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MP3450/MP3500/MP3600 User Guide (V1.0)
MP3450/MP3500/MP3600 User Guide (V1.0)

Created by the HTML-to-RTF Pro DLL .Net 4.6.10.19 Q1. (a) The
Created by the HTML-to-RTF Pro DLL .Net 4.6.10.19 Q1. (a) The

... The diagram represents a simple transformer used to light a 12 V lamp. When the power supply is switched on the lamp is very dim. ...
BDTIC
BDTIC

... Considering that the total charging energy has to be delivered by the capacitor directly together with the equation Q=C*U we find that the voltage change at the capacitor to charge or discharge the gate is calculated as dUc=Qg/Cbias. An acceptable voltage change at a single switching cycle of about ...
UNIVERSAL MOTOR - Home
UNIVERSAL MOTOR - Home

... The starting torque of a universal motor is determined by the current that flows through the armature www.technologyfutuare.com ...
WIPO IPC: Internet Publication
WIPO IPC: Internet Publication

... the whole mechanical aspect of the apparatus or devices, whereas the electrical aspect, as such, is covered by subclass H05B;  In the case of lighting, this mechanical aspect should be taken to cover the material arrangement of the various electric elements, i.e., their geometrical or physical posi ...
Exam Questions on Keeping Things Moving
Exam Questions on Keeping Things Moving

Temperature Modeling and Control of Induction Furnace System
Temperature Modeling and Control of Induction Furnace System

... principle, included heat energy generated and heat loss. Temperature controller of induction furnace system is designed here by setting the PWM, by which the power of induction furnace can be adjusted, to have a controlled temperature. Three cases of PI controllers presented, there were, case I, the ...
PDF
PDF

... components. It provides basic blocks from different physical domains such as electrical, mechanical, hydraulic, pneumatic, thermal, etc. The model can be constructed, as in Simulink, by assembling the building blocks together to build a complete system with the ability to have different domains. Con ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... SOI wafers. The SmartcutTM and NanocleaveTM processes both employ high dose ion implantation (using hydrogen or other light species), either alone or in combination with other steps, to form a weakened silicon layer that splits (i.e., “peels off”) the donor wafer, allowing the “layer transfer” to oc ...
3.4 Metering Functions
3.4 Metering Functions

... The motor and energy management system shall consist of a Current/Voltage Measurement Module and a Main CPU Module. The motor and energy managements system shall have a current operating range of 0.1 and 2000 amperes. The motor and energy management system shall provide current, voltage, power and t ...
P84024
P84024

... signaling appliances, powered by the same source and include any required safety factor. ...
LM22673 - Texas Instruments
LM22673 - Texas Instruments

... SNVS586O – SEPTEMBER 2008 – REVISED NOVEMBER 2014 ...
New Sales Tools
New Sales Tools

... • Does not protect against under or over voltage ...
Copyright © Wolfsburg West 2001 Starter Circuit Troubleshooting
Copyright © Wolfsburg West 2001 Starter Circuit Troubleshooting

... At 12.8 volts a 12-volt battery is fully charged. Static charge is the voltage across the battery with all electrical components turned off. At 13.09 volts, our battery is in tip top shape! ...
MAX8794 Low-Voltage DDR Linear Regulator General Description Features
MAX8794 Low-Voltage DDR Linear Regulator General Description Features

... of the transistor (IN) is regulated to provide VOUT. By using separate bias and power inputs, the MAX8794 can drive an n-channel high-side MOSFET and use a lower input voltage to provide better efficiency. The MAX8794 regulates its output voltage to the voltage at REFIN. When used in DDR application ...
SG6742WMR Highly Integrated Green-Mode PWM Controller
SG6742WMR Highly Integrated Green-Mode PWM Controller

... SG6742WMR integrates a frequency-hopping function that helps reduce EMI emission of a power supply with minimum line filters. The built-in synchronized slope compensation achieves stable peak-current-mode control. The proprietary internal line compensation ensures constant output power limit over a ...
EES612-Lab2-DC Motor.. - Department of Electrical and Computer
EES612-Lab2-DC Motor.. - Department of Electrical and Computer

Type Open/Close actuators
Type Open/Close actuators

... 0.5 A (resistive load); 0.2 A (inductive load) ...
Spec Sheet - American Standard
Spec Sheet - American Standard

Aalborg Universitet Coordinated Power Control Strategy based on Primary-Frequency-Signaling for Islanded Microgrids
Aalborg Universitet Coordinated Power Control Strategy based on Primary-Frequency-Signaling for Islanded Microgrids

... This paper adopted an interesting way of communication which using the information of AC bus for coordinated operation. In this way, the external communication can be removed since the coordination relies on the power bus. It needs to notice that bus signaling method can also be used in DC grid powe ...
GS7700A 07/13/06 POWER DELEGATOR SERIES 7700A POWER
GS7700A 07/13/06 POWER DELEGATOR SERIES 7700A POWER

... 5.4.5 All transformers shall be designed to operate at safe temperatures of less than 150° C (hot spot) above ambient. Transformer over temperature shut down must be provided at 200° C. ...
A Door Motion Energy Harvesting System for Powering an Electronic
A Door Motion Energy Harvesting System for Powering an Electronic

... typical rotational speed of 7.5rpm, an open-circuit voltage of about 6.8V would be produced. The maximum power transfer would therefore occur when the generator output terminals were loaded to produce a voltage of about 3.4V. A boost converter would therefore be required to produce a voltage near th ...
FSQ0565RS/RQ Green-Mode Fairchild Power Switch (FPS™) for Quasi-Resonant Operation -
FSQ0565RS/RQ Green-Mode Fairchild Power Switch (FPS™) for Quasi-Resonant Operation -

... current source is disabled. The FPS™ continues its normal switching operation and the power is supplied from the auxiliary transformer winding unless VCC goes below the stop voltage of 8V. VDC ...
ce-b36 metal clad - Casagrande Elettrocostruzioni SpA
ce-b36 metal clad - Casagrande Elettrocostruzioni SpA

... circuit making current when close to under load. The speed of the snap action closing operation is independent of controls. A manual switch operating lever is provided on the front of the switchbord. The device is provided with auxiliary switches for signalling the open and closed positions. ...
ESF.ESFP Smart battery charger user manual
ESF.ESFP Smart battery charger user manual

< 1 ... 362 363 364 365 366 367 368 369 370 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report