• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Project_Report_KamChong
Project_Report_KamChong

... multiplier was implemented in Cadence using 90nm Predictive Technology Model (PTM) library and simulated for the worstcase scenario for both 16 and 8-bit output precision. The results are recorded in Table 1. As seen from the simulation results in the table, despite the small overhead due to scaling ...


... server/workstation host PC. This guide discusses each wiring process separately. Understanding all of these processes makes this project much simpler and guarantees success. ...
3-V to 17-V 1-A Step-Down Converter with DCS
3-V to 17-V 1-A Step-Down Converter with DCS

... Available in a 2 × 2 mm WSON-8 Package ...
Instruction Manual
Instruction Manual

Comprehensive Modulation and Classification of Faults and
Comprehensive Modulation and Classification of Faults and

... Generally speaking, faults in PV system could be occurred into two side of the system: DC side and AC side, the interface between this to part is DC/AC inverter that connected to grid. Internal maximums point power tracker algorithm with some method must be applied for rising efficiency of the syste ...
Lab 7 help - IT 318
Lab 7 help - IT 318

... current and all other connections made, turn on the DC power supply. The motor should turn on but will not move very fast since its input to the commutator is only 1V. If your motor does not turn on, turn off the power supply immediately and check your connections. If it turns on, proceed to step 2. ...
Voltage (Multi-Range) Sensor
Voltage (Multi-Range) Sensor

... This Voltage sensor is a high precision, quick response voltage sensor, designed to measure three ranges of voltage - s: ±1 V, ±10 V and ±25 V. It is a precise differential sensor, capable of measuring both direct and alternating voltages. It is ideal for use in a wide range of experiments in Physic ...
Acrobat Distiller, Job 7
Acrobat Distiller, Job 7

... The PM Series products are designed to meet the industrial control equipment guidelines outlined by Underwriter’s Laboratories (UL) Bulletin 508 and Canadian Standards Association (CSA) Standard 22.2. Please consult the factory for the specific model approval status. ...
P O W E R DIGITAL SWITCHBOARD METERS
P O W E R DIGITAL SWITCHBOARD METERS

... meter is a programmable ASIC Power Measurement Chip (PMC) which was jointly developed by the General Electric Company and Yokogawa Electric Corporation. This unique PMC capability will continue to expand into many new power measurement and control products offered by Yokogawa Corporation of America. ...
HIGH CURRENT SWITCHING REGULATORS
HIGH CURRENT SWITCHING REGULATORS

Data Center Power and Cooling White Paper
Data Center Power and Cooling White Paper

... cool data center into the outside ambient environment. The power requirements for cooling a data center depend on the amount of heat being removed (the amount of IT equipment in the data center) and the temperature delta between the data center and the outside air. The rack arrangement on the data c ...
msm6100™ chipset solution
msm6100™ chipset solution

Chapter 19
Chapter 19

... – if the p-type side is made negative with respect to the n-type side the height of the barrier is increased – the number of majority charge carriers that have sufficient energy to surmount it rapidly decreases – the diffusion current therefore vanishes while the drift current remains the same – thu ...
Efficiently Amplified
Efficiently Amplified

... with fixed supply voltage, the dc supply is controlled appropriately to amplify the signal, and the dissipated power of the PA is minimized. In this article, we briefly introduce supply modulated PAs, including the conventional EER, H-EER, and ET transmitters [1]–[17]. Much research on the supply mo ...
150LECTURE11CHAPTER11INDUCTORS Lecture Notes Page
150LECTURE11CHAPTER11INDUCTORS Lecture Notes Page

Power Electronic Device Protection (VFD, Drive Protection)
Power Electronic Device Protection (VFD, Drive Protection)

... UL 508C, the standard to which drives and soft starters are listed, provides at least two levels of short-circuit protection. The Standard Fault Current test is mandatory to be listed, and there is an optional High Fault Current test which can be performed during the listing of the device. UL also p ...
Designing a Qi-compliant receiver coil for wireless power systems
Designing a Qi-compliant receiver coil for wireless power systems

... vary in different system scenarios. Due to the interoperability nature of the Qi standard, the Rx coil can be placed on many different types of Tx’s that may influence the Rx-coil inductance—and hence the electrical response. Per Section 4.2.2.1 of the WPC specification,1 the Rx-coil inductance, L′S ...
Electricity Chapter 8.2 textbook
Electricity Chapter 8.2 textbook

... 1. How did your group show the change in potential energy in different parts of the circuit? 2. How did your group show how energy was transformed? 3. What was the most difficult part about making a human model of an electrical circuit? 4. In what ways was your model an inaccurate representation of ...
Magnetic Performance of a Single Phase Induction Motor under
Magnetic Performance of a Single Phase Induction Motor under

... windings are excited by a two-phase symmetrical ac-voltage, a smooth rotating field will be produced. ...
Kreutter: Magnetism What is Magnetism? Part 1: A Magnet Take 2
Kreutter: Magnetism What is Magnetism? Part 1: A Magnet Take 2

... Make a simple circuit with a D battery and 2 wires. You should tape the battery and wires together. You should include a light bulb so you are sure current is flowing. Be sure one of the wires in the circuit is aligned along the geographical North-South direction (use the compass to determine this b ...
SLO-SYN® 230-T, 430-T, 230-TH, and 430-TH
SLO-SYN® 230-T, 430-T, 230-TH, and 430-TH

3.3V 5V ±12V housekeeping IC
3.3V 5V ±12V housekeeping IC

Paralleling Dissimilar Generators
Paralleling Dissimilar Generators

... generator set control systems cannot simply monitor bus voltage and speed as a reference for maintaining equal output levels, as they do when operated in isolation from one another. If, for example, one set operates at a higher excitation level than the other sets, the reactive load will not be shar ...
1. What is the nature from a safety standpoint of the switch in the
1. What is the nature from a safety standpoint of the switch in the

... to 8 hard-wired circuits. This limits the number of circuits you can connect to the transfer switch. iii. Since GenerLink uses your existing breaker panel, you can run any large 120 or 240-volt appliance up to your generator’s capacity. Your well pump, water heater, sump pump, electric range, clothe ...
RT8450B - Richtek
RT8450B - Richtek

... These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Note 2. I ...
< 1 ... 320 321 322 323 324 325 326 327 328 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report