• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Weld Package Semi Automatic mobile
Weld Package Semi Automatic mobile

HL6165
HL6165

... better line current shaping and better output voltage regulation compared with the conventional dual loop control scheme. Based on the proposed simplified PWM, a novel feed forward control scheme is presented in this section. For a convenient explanation, the converter operated in the rectifier mode ...
Efficiency Improvement of 3 Phase Induction Motor
Efficiency Improvement of 3 Phase Induction Motor

... Assistant Professor, Karpagam College of Engineering, Coimbatore, Tamilnadu, India1,2,3 ABSTRACT: Induction motor is the electrical drives which is widely used in major industrial applications. Generally efficiency of the induction motor is poor at lower load condition. It is necessary to improve th ...
ADDC02808PB 28 V, 200 W Pulsed DC/DC Converter with Integral
ADDC02808PB 28 V, 200 W Pulsed DC/DC Converter with Integral

... dual interleaved power trains operating 180° out of phase. Each power train switches at a fixed frequency of 500 kHz, resulting in a 1 MHz fixed switching frequency as seen at the input and output of the converter. In a flyback topology, energy is stored in the inductor during one half portion of th ...
Compact Dual-Fed Distributed Power Amplifier , Member, IEEE
Compact Dual-Fed Distributed Power Amplifier , Member, IEEE

... made arbitrarily low, but the drain line characteristic impedance is constrained by (1). Fortunately, the output capacitance is less than the input capacitance. Alternatively, the input and output of each FET can be parallel resonated by shunt inductances to eliminate the effects of FET input and ou ...
Xs Series - HARMAN Professional Solutions
Xs Series - HARMAN Professional Solutions

ElEctricity
ElEctricity

... filings again relaxed into their random arrangement on the card. The AmpERE With further experimentation, Ampère discovered that two parallel electric currents running in the same direction attract each other, and that parallel currents running in opposite directions repel each other. The modern uni ...
Application Guidelines for On
Application Guidelines for On

... footprint, so be very careful. Modules are not interchangeable. They most likely are designed using different circuit topologies and could exhibit widely different electrical performance. At the least, EMI performance would be different. If interaction is required among the modules, such as for curr ...
IS 6008 (1989): Arc Welding Power Source, Single Operator
IS 6008 (1989): Arc Welding Power Source, Single Operator

... necessary to withstand rough usage. It shall be provided with an enclosure or tank which shall enclose all live metal parts other than a flexible supply cord or cable and output terminals. ...
Aalborg Universitet controller
Aalborg Universitet controller

... converters [13]–[15]. For example, it can contribute to a decrease of the fundamental component of the converter output, and also it will generate low order harmonics in the output PWM voltage of the converter [16]. Both issues can lead to distortions of the injected current [4] as well as additiona ...
DC-AC Inverter - Samlex America
DC-AC Inverter - Samlex America

... item you wish to operate is less than inverter’s power. (If the power consumption is rated in amps AC, simply multiply by the AC volts (230) to determine the approximate wattage). The inverter will shut down if it is overloaded. The overload must be removed before the inverter will restart. Resistiv ...
Weidmann Diagnostic Solutions Electrostatic Precipitator
Weidmann Diagnostic Solutions Electrostatic Precipitator

... Electrostatic precipitators (ESPs) are critical to the clean delivery of electric power as well as controlling particulate emissions from various industrial processes. The transformer/rectifier is a major component of the power supply system to the ESPs. The failure of a transformer/rectifier can li ...
04_ELC4345_Fall2013_DC_DC_Buck
04_ELC4345_Fall2013_DC_DC_Buck

Document
Document

... transient voltages can cause electrical shock and/or damage to equipment. ...
Slide 1
Slide 1

... in optical transmitters, modulation techniquesAnalog, Digital, Optoelectronics device for receiverAPD’s PCN photodiodes, etc. Low- noise front ends for optical receiver; Free space and fiber- optic communication: Basic of fiber optic- characteristics, ...
TND6197 - Stepping Motors and Stepping Motor Control System
TND6197 - Stepping Motors and Stepping Motor Control System

... Below is basic information on common motor choices for positioning motor applications. Note that there are a few other possible choices, such as AC Induction motors or Piezo motors, but these three listed motor types represent the huge majority of applications in use today for general purpose motion ...
08_chapter 3
08_chapter 3

Gas-insulated switchgear up to 420 kV, 63 kA, 5000 A
Gas-insulated switchgear up to 420 kV, 63 kA, 5000 A

... switching devices, all operating-mechanism attachments are preset at the factory prior to shipment. All flanges where the modules join to other equipment are protected against corrosion and sealed with transport covers. All components are packed according to means, duration, and route of transport a ...
auragen® induction power source
auragen® induction power source

CHAPTER 1: Introduction to Computer Parts and
CHAPTER 1: Introduction to Computer Parts and

... • Hard drives and other drives – Hard drives may also be called hard disk drive (HDD) • Permanent storage used to hold data and programs ...
Halo LED ML709835ICAT120D spec sheet
Halo LED ML709835ICAT120D spec sheet

... HAL O LED Modul e  900 Ser i es For New a nd Ex i s t i ng I ns t al l at i ons The Halo LED ML7098xxICAT120D modules are designed for retrofit applications with an Edison screw base adapter (included with the module) for use in existing housings OR may also be used in new construction with the LED  ...
UFC 3-540-01 Engine-Driven Generator Systems for
UFC 3-540-01 Engine-Driven Generator Systems for

... planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD (AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other custo ...
Performance Optimization of Induction Motors During Voltage
Performance Optimization of Induction Motors During Voltage

... keep the current constant at the preset value during starting period. Current in the third line can be deduced from the two signals by the C. These will then be used for protection purposes against overload, unbalanced operation, and faults. The three line-to-line voltage signals are used only for z ...
Optimal Commutation of a BLDC Motor by Utilizing the Symmetric
Optimal Commutation of a BLDC Motor by Utilizing the Symmetric

... a BLDC motor is energized at the incorrect commutation position. VBF and VEF are the filtered terminal voltages of the nonenergized phase at the beginning and end of the commutation period, respectively.  Measured values of VBF and VEF are not symmetric not only because the ...
A simple maximum power point tracker for thermoelectric generators
A simple maximum power point tracker for thermoelectric generators

... Generators (TEGs) comprise multiple semiconductor thermocouples (e.g. constructed using Bismuth Telluride with p- and ndoping), which are capable to generate electric energy when subject to a temperature difference across their hot and cold sides [2]. The TEGs feature high reliability, do not contai ...
< 1 ... 288 289 290 291 292 293 294 295 296 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report