• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CHAPTER 11 R-F COMPONENTS BY A.   E. WHITFORD 11.1. The
CHAPTER 11 R-F COMPONENTS BY A. E. WHITFORD 11.1. The

... For the usual upper design limit of VSWR ...
Department of Electrical Engineering and Computer Science
Department of Electrical Engineering and Computer Science

... Computation structures Electric power and energy systems: Electric energy transmission and distribution Energy market Electric power systems analysis and operation Modelling of electromagnetic systems Numerical optimization ...
Overlapping Neutral
Overlapping Neutral

... It is safe to assume that if the switching device in question operated slowly enough to allow even a close approximation of the open neutral static unbalanced conditions described, the contacts of the switch could fail. It is a well-known fact that successful operation of any disconnect device, espe ...
IC=S.OA, IB=I.OA - New Jersey Semiconductor
IC=S.OA, IB=I.OA - New Jersey Semiconductor

Electrical Machines-III
Electrical Machines-III

POWER ELECTRONICS AND SIMULATION LAB
POWER ELECTRONICS AND SIMULATION LAB

... Study of SCR, MOSFET and IGBT and their firing circuits ...
The development of power electronics in Europe
The development of power electronics in Europe

... transformers. In contrast the rotary converter, system Leonard allowed an easy change of the DC voltage by regulating generator's excitation and load peaks could be reduce by the rotating mass. On the other side mercury arc rectifiers can work in a wide range of voltages and frequencies, so that one ...
DI-8B42 2-Wire Transmitter Interface Modules
DI-8B42 2-Wire Transmitter Interface Modules

Activity 2 Electrical Energy Power
Activity 2 Electrical Energy Power

... A 120 volt light bulb has a current of 0.833 A. running through it for 30 seconds. How much electrical energy does it use in this time? (Include units in your answer!) Equation: Solution: ...
PV Power Source Labeling in a SolarEdge system
PV Power Source Labeling in a SolarEdge system

... The maximum power point current is the lower of the following 2 values: The total STC DC power rating for all PV Modules divided by the nominal string voltage value listed in item (2) below for maximum power point voltage. For example, a system with 28 – 260 watt PV Modules with the SE6000A-US inver ...
1 Tools and Electrical - Washington Fire Chiefs
1 Tools and Electrical - Washington Fire Chiefs

... Disclaimer: The content in this slide show has not been reviewed by the Department of Labor and Industries for accuracy and has been provided as “sample” curriculum only. Each Authority Having Jurisdiction must design, take authority of, and responsibility for, the actual training done by the Depart ...
section 263533 - power factor correction
section 263533 - power factor correction

... This Product MasterSpec Section is licensed by ARCOM to Staco Energy Products Co ("Licensee"). This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section. Revisions made to the original MasterSpec text are made sole ...
Photovoltaic Terminology
Photovoltaic Terminology

High Efficiency Power Amplifier Product Instructions
High Efficiency Power Amplifier Product Instructions

... ambient temperature is too high, it is recommended that effective measures should be taken to reduce temperature. Requirements on grid power supply voltage by the equipment: AC 220V (-15% to +10%) 50-60Hz. In case of too high, too low voltage or that fluctuating greatly, it is recommended that AC re ...
DC-Resonance Powers Wireless Transfer
DC-Resonance Powers Wireless Transfer

... Fig. 6 shows the merit of the DC-resonance system. In comparison to the magnetic field resonance technique, the system structure is simpler and the size is smaller and lighter. As a result, the power efficiency of the system is enormously enhanced. In comparison to the electromagnetic induction meth ...
Speaker Power Requirements
Speaker Power Requirements

... operation? Should there be any de-rating of systems to allow for this? Yes. JBL defines the following three categories of loudspeaker application, each requiring an adjustment of the system's IEC rating: A. For carefully monitored applications where peak transient capability must be maintained, a sy ...
Some Final Exam Questions
Some Final Exam Questions

... In order to obtain the Thevenin equivalent for a 1-port circuit, one should set the values of all dependent and independent sources to zero and then calculate the equivalent resistor for the port. (false, should not set the dependent sources to zero!) In order to calculate the Norton current for a 1 ...
Spacecraft Power Systems
Spacecraft Power Systems

... While in sunlit orbit, the motor will spin the flywheel to a fully charged speed – generator mode will take over to discharge the flywheel and power the satellite during the eclipse phase – present flywheel technology is about four times better than present battery technology on a power stored vs. w ...
Unit 7: Electrical Circuits and Systems Review KEY
Unit 7: Electrical Circuits and Systems Review KEY

... Current is the same for all points on a series circuit Voltage is the same for all points in a parallel circuit ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... We can use the traditional controller also for controlling power flow of this lines but frequent tuning is again a problem. Hence to overcome from above mention problem, we can use the fast acting power electronics controllers called FACTS devices. In late 1980’s ,Electric power research institute i ...
Twenty Questions - Kelso High School
Twenty Questions - Kelso High School

... Explain whether the resistance of the component show has increased or decreased. ...
1150 - Altwise
1150 - Altwise

... LPMS900X-L Light Saver is the best solution to save power on lighting at homes, buildings, and industries. LPMS900X-L Light Saver is designed according with the latest technology, with fully integrated microprocessor based electronic circuit, to sense, control and optimize lighting loads. ...
The experience of the Qualistar,
The experience of the Qualistar,

... Designed to cover all 600 V CAT IV and 1000 V CAT III applications in compliance with the IEC 61010 standard, the Qualistar+ range is divided up according to the functions provided and the connections available: C.A 8331 & C.A 8333: 4 voltage inputs and 3 current inputs,t, C.A 8336 & C.A 8435: 5 vol ...
Electric Circuits
Electric Circuits

... The instantaneous real power can never be negative, which is also  shown in the figure. In other words, power cannot be extracted  from a purely resistive network. Rather, all the electric energy is  dissipated in the form of thermal energy. Electric Circuits ...
A High Step-up Bidirectional Isolated Dual-Active
A High Step-up Bidirectional Isolated Dual-Active

... A bidirectional isolated dual-active-bridge (DAB) converter with three-level voltage-doubler rectifier (TL-VDR) is presented for energy storage applications. The voltage conversion ratio is enhanced and the voltage stresses on transformer windings are reduced with the help of TL-VDR. Optimized pulse ...
< 1 ... 1007 1008 1009 1010 1011 1012 1013 1014 1015 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report