Vacuum circuit-breaker up to 36 kV
... switches are not necessarily dependent on the switching device‘s position, but are actuated e.g. via cams or via various elements installed on the switch. The control switches are wired to the terminal strip; on request, a plug-and-socket connection (with connector and connector base) is ...
... switches are not necessarily dependent on the switching device‘s position, but are actuated e.g. via cams or via various elements installed on the switch. The control switches are wired to the terminal strip; on request, a plug-and-socket connection (with connector and connector base) is ...
DC MOTORS AND GENERATORS
... Terminal Conditions Calculated for dc Compound Generator . . . . . . . . Added Series Field Calculated to Produce Flat Compounding in dc Generator . . . . . . . . . . . . . . . . . . . . . . . . . Calculation of Interpole Windings for a dc Generator . . . . . . . . . . . . Design of Compensating Win ...
... Terminal Conditions Calculated for dc Compound Generator . . . . . . . . Added Series Field Calculated to Produce Flat Compounding in dc Generator . . . . . . . . . . . . . . . . . . . . . . . . . Calculation of Interpole Windings for a dc Generator . . . . . . . . . . . . Design of Compensating Win ...
DRV8885 1.5-A Stepper Motor Driver With
... The DRV8885 is capable of driving up to 1.5 A full scale or 1.0 A rms output current (depending on proper PCB ground plane for thermal dissipation and at 24 V and TA = 25°C). The DRV8885 integrated current sense functionality eliminates the need for two external sense resistors. The STEP/DIR pins pr ...
... The DRV8885 is capable of driving up to 1.5 A full scale or 1.0 A rms output current (depending on proper PCB ground plane for thermal dissipation and at 24 V and TA = 25°C). The DRV8885 integrated current sense functionality eliminates the need for two external sense resistors. The STEP/DIR pins pr ...
21 circuits, bioelectricity, and dc instruments
... avoid an electrical shock, who could reduce the current by wearing high-resistance rubber-soled shoes. It could be a disadvantage if one of the resistances were a faulty high-resistance cord to an appliance that would reduce the operating current.) ...
... avoid an electrical shock, who could reduce the current by wearing high-resistance rubber-soled shoes. It could be a disadvantage if one of the resistances were a faulty high-resistance cord to an appliance that would reduce the operating current.) ...
Time Varying Circuits
... and a 4.90-Ω resistor are connected with a switch to a 6.00-V battery as shown in Figure P32.27. (a) If the switch is thrown to the left (connecting the battery), how much time elapses before the current reaches 220 mA? (b) What is the current in the inductor 10.0 s after the switch is closed? (c) N ...
... and a 4.90-Ω resistor are connected with a switch to a 6.00-V battery as shown in Figure P32.27. (a) If the switch is thrown to the left (connecting the battery), how much time elapses before the current reaches 220 mA? (b) What is the current in the inductor 10.0 s after the switch is closed? (c) N ...
M S - P
... the resonant network. The resistance value at the resonant frequency decreased with an increasing distance between the coupled coils. Even so, detection of the sensors’ state was feasible at all tested distances, from 0.5 cm up to 3 cm. The second proposed alternative consists on remote powering, vi ...
... the resonant network. The resistance value at the resonant frequency decreased with an increasing distance between the coupled coils. Even so, detection of the sensors’ state was feasible at all tested distances, from 0.5 cm up to 3 cm. The second proposed alternative consists on remote powering, vi ...
Novel Advancements in Solid-State Magnet Control
... programmable automatic reduction in the magnet current from lifting current to holding current. As seen in the previous examples, the holding current required is approximately two thirds of the lifting current which results in a reduction of power consumption by approximately on third. The second me ...
... programmable automatic reduction in the magnet current from lifting current to holding current. As seen in the previous examples, the holding current required is approximately two thirds of the lifting current which results in a reduction of power consumption by approximately on third. The second me ...
The MEG Made Ridiculously Simple
... In the following, I admit to stealing some nice slides from my office-mate Matti Hamalainen (MSH), for which I thank him. Several other slides were blatantly lifted from various publications and websites, here and there..… Lets face it: parts of this talk are not really “ridiculously simple”; sorry ...
... In the following, I admit to stealing some nice slides from my office-mate Matti Hamalainen (MSH), for which I thank him. Several other slides were blatantly lifted from various publications and websites, here and there..… Lets face it: parts of this talk are not really “ridiculously simple”; sorry ...
Emon Meter Installation
... The E-Mon D-Mon® Class 2000 meter is wired as a single-, dual- or three-element unit that is used to monitor electric power to individual loads after the utility meter. Installation must be performed by qualified personnel and ONLY according to these instructions and all applicable electrical codes. ...
... The E-Mon D-Mon® Class 2000 meter is wired as a single-, dual- or three-element unit that is used to monitor electric power to individual loads after the utility meter. Installation must be performed by qualified personnel and ONLY according to these instructions and all applicable electrical codes. ...
18_DC_Circuits - jmr physics website
... Comment on the fact that your calculated values do not add to 2 V. Hence, discuss the factors that affect the choice of voltmeters for practical purposes. ...
... Comment on the fact that your calculated values do not add to 2 V. Hence, discuss the factors that affect the choice of voltmeters for practical purposes. ...
SPECIAL PROTECTION SCHEME
... the primary time constant, the secondary time constant of the current transformer and the magnitude of the DC component. The remanance also has impact on the overdimensioning. The commonly used formulae for calculation of the overdimensioning factor are often simplified considering the primary time ...
... the primary time constant, the secondary time constant of the current transformer and the magnitude of the DC component. The remanance also has impact on the overdimensioning. The commonly used formulae for calculation of the overdimensioning factor are often simplified considering the primary time ...
Galvanometer

A galvanometer is a type of sensitive ammeter: an instrument for detecting electric current. It is an analog electromechanical actuator that produces a rotary deflection of some type of pointer in response to electric current through its coil in a magnetic field.Galvanometers were the first instruments used to detect and measure electric currents. Sensitive galvanometers were used to detect signals from long submarine cables, and to discover the electrical activity of the heart and brain. Some galvanometers use a solid pointer on a scale to show measurements; other very sensitive types use a miniature mirror and a beam of light to provide mechanical amplification of low-level signals. Initially a laboratory instrument relying on the Earth's own magnetic field to provide restoring force for the pointer, galvanometers were developed into compact, rugged, sensitive portable instruments essential to the development of electrotechnology. A type of galvanometer that records measurements permanently is the chart recorder. The term has expanded to include use of the same mechanism in recording, positioning, and servomechanism equipment.