• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Smart automation
Smart automation

... Unplanned downtimes are a disaster for factories. Defective cordsets in drag chains and robot tube packages are one of the main causes of these malfunctions. A broken wire – it’s no more than that, but difficult to detect – can cause considerable costs that were not anticipated. At worst, it may be ...
Document
Document

... This technique treats each device as a separate test. It isolates the device being tested from the rest of the circuit by using backdriving (sometimes called node forcing) to apply signals to the device, and guarding to ensure no other device on the board interferes with the outputs states being mea ...
Sensor Guard Technical Presentation TelCel Jan2007
Sensor Guard Technical Presentation TelCel Jan2007

... • SPDs are designed to cope with specific surge events ...
isp series - Schneider Electric Motion USA
isp series - Schneider Electric Motion USA

... in stepping and DC motors. Conventional switching power supplies are designed for the constant, unvarying loads of circuit boards and are not tolerant of the current surges produced by rapid changes in power demand and the inductance of motor coils. The ISP is well protected with designed-in short c ...
Abstract - PG Embedded systems
Abstract - PG Embedded systems

Mid Semester Presentation - High Speed Digital Systems Laboratory
Mid Semester Presentation - High Speed Digital Systems Laboratory

... • Why do signal-integrity effects occur, and why so much more today than before? “when a higher-frequency signal (i.e., a signal that switches more quickly) travels along the same trace, the trace exhibits circuit characteristics that distort and degrade the signal.” ...
Slash Rated Devices 2
Slash Rated Devices 2

... Slash-rated devices must be utilized only on solidly grounded systems. This automatically eliminates their usage on resistance-grounded and ungrounded systems. They can be properly utilized on solidly grounded wye systems, where the voltage to ground does not exceed the smaller of the circuit breake ...
Testing Analog Circuits by Supply Voltage Variation and Supply
Testing Analog Circuits by Supply Voltage Variation and Supply

... discussed. This technique aims to sensitize faults by causing transistors to switch from their normal saturation mode of operation. Hence, the supply current, in both DC and AC domains is changed sufficiently to give a clear indication of ...
Rectification - Animated Science
Rectification - Animated Science

... • Supply current to circuits ...
Application Note 1681 Design Migration from the LM1881
Application Note 1681 Design Migration from the LM1881

... The LMH1980 accepts an analog video input with either bilevel sync or tri-level sync and automatically detects the video format, thus eliminating the need for external RSET adjustment required by the older LM1881 to support different line rates. Only a fixed 10 kΩ 1% external resistor is needed to s ...
Lesson 3: Learning the Language for DC Circuits
Lesson 3: Learning the Language for DC Circuits

... 2.3 We learned that for a light bulb to glow, the two poles of a battery must be connected to the light bulb with conducting wires. Come up with analogies that can explain and predict phenomena related to electric circuits. Parts of the Create your own analogy Electric Circuit Battery ...
Electronics Formal Homework 2
Electronics Formal Homework 2

Chapter 4
Chapter 4

...  They wear themselves out and need to be periodically replaced.  They were expensive to produce and fragile.  Tubes still find their way in certain applications (microtubes in the military). ...
Low and Medium Voltage Circuit Breakers
Low and Medium Voltage Circuit Breakers

Slide 1 - EnhanceEdu
Slide 1 - EnhanceEdu

... Assumes that the faults are due to interconnects only and the components are fault free. Typical structural faults ◦ Short – by connecting unnecessary nodes ◦ Open – by breaking of a connection ...
Avoid generating capacity losses in aging hydropower plants
Avoid generating capacity losses in aging hydropower plants

... increasing the voltage line-to-ground (L-G) until the insulation of the power system breaks down. Line-to-line (L-L) voltage values are measured even though the actual measurement location is L-G. For every peak in the voltage, there is a restrike in the arc. Because there is no ground reference, th ...
Technical Justification for the CompactRIO
Technical Justification for the CompactRIO

service bulletin
service bulletin

... latest software in the HK38EA010 is designed to be a complete solution, extensively tested in the lab and verified in problem field sites. 2) Improved False start Detection: The HK38EA010 software also incorporates an improved false start detection method: When particularly difficult start condition ...
CDR Presentation
CDR Presentation

Reliability Assessment of an Electronic Accessory: a Case Study of a... Phone Charger in Nigeria
Reliability Assessment of an Electronic Accessory: a Case Study of a... Phone Charger in Nigeria

... special consideration given to factors like environment of use ,quality of power supply and service personnel. A comparative assessment was made on the reliability of the system when operated within the Nigerian environment and when operated within the environment for which it was designed for (Chin ...
Deltec CA1 Product Brief (pdf download)
Deltec CA1 Product Brief (pdf download)

... paramount importance and can have a dramatic effect on sound quality. A specially constructed screened audio grade low noise toroidal transformer is employed. RF decoupling and filtering techniques have been applied to the supply inputs and outputs resulting in a much sweeter, smoother more natural s ...
ESP-AUTO - Thomas Research Products
ESP-AUTO - Thomas Research Products

Wavelet transform as a postprocessing diagnostic tool for fault
Wavelet transform as a postprocessing diagnostic tool for fault

... transmission network has been widely implemented in real time, because of its outstanding advantages, such as economical efficiency and flexibility. Moreover, HVDC transmission systems that utilize the line-commutated converter (LCC) are successful and have been running for many years (Wang and Sa-N ...
fault location calculation based on two terminal
fault location calculation based on two terminal

... Assistant Professor, Department of Electrical & Computer Engineering, Samara University, Ethiopia ...
Kirchhoff`s Laws and Superposition
Kirchhoff`s Laws and Superposition

... In this lab, Kirchhoff’s laws will be investigated using a more complex circuit than in the previous labs. Two voltage sources and seven resistors are included in the circuit. Kirchhoff’s voltage law will be verified for several loops of this network and Kirchhoff’s current law will be verified for ...
< 1 ... 222 223 224 225 226 227 228 229 230 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.