Four-Speed Fan Control Using Simple Remote
... • O_SP0 and O_SP1 activate when the temperatures measured by D0 or D1 exceed the associated setpoints of T_SP0 or T_SP1. • O_CRIT activates when the temperature measured by either D0 or D1 exceeds set point T_CRIT. T_CRIT can be set at 1°C intervals from -40˚C to +125˚C. T_SP0 and T_SP1 can be set a ...
... • O_SP0 and O_SP1 activate when the temperatures measured by D0 or D1 exceed the associated setpoints of T_SP0 or T_SP1. • O_CRIT activates when the temperature measured by either D0 or D1 exceeds set point T_CRIT. T_CRIT can be set at 1°C intervals from -40˚C to +125˚C. T_SP0 and T_SP1 can be set a ...
IOSR Journal of Computer Engineering (IOSR-JCE)
... Integration of High Temperature Superconductor Fault Current Limiter (HTSFCL) in power system network will provide instantaneous (sub cycle) current limitation abilities, which mitigates the effects and the buildup of fault currents in the power system network .The devices in electronic and electric ...
... Integration of High Temperature Superconductor Fault Current Limiter (HTSFCL) in power system network will provide instantaneous (sub cycle) current limitation abilities, which mitigates the effects and the buildup of fault currents in the power system network .The devices in electronic and electric ...
5240 User's Manual
... Make the same adjustments to the high and low temperature limits (T-High Lim and T-Low Lim), as appropriate for your application. The unit comes pre-programmed for the BetaTHERM 10K3A1 thermistor. If the TECSource is being connected to a LaserMount, no changes need to be made, as this is the thermis ...
... Make the same adjustments to the high and low temperature limits (T-High Lim and T-Low Lim), as appropriate for your application. The unit comes pre-programmed for the BetaTHERM 10K3A1 thermistor. If the TECSource is being connected to a LaserMount, no changes need to be made, as this is the thermis ...
Lambda Sensor LSU 4.2
... dual cell limiting current sensor with integrated heater. Its monotonic output signal in the range of lambda 0.65 to air makes the LSU capable of being used as a universal sensor for lambda 1 measurement as well as for other lambda ranges. The connector module contains a trimming resistor, which def ...
... dual cell limiting current sensor with integrated heater. Its monotonic output signal in the range of lambda 0.65 to air makes the LSU capable of being used as a universal sensor for lambda 1 measurement as well as for other lambda ranges. The connector module contains a trimming resistor, which def ...
Intrinsic dissipation in high-frequency micromechanical resonators * P. Mohanty,
... determine the dominant mechanism by ruling out the other mechanisms through their parametric dependence or lack thereof. Experimentally, this is crucial to the identification of an unknown mechanism. In a certain region of parameter space, all the dependencies must be accounted for by this mechanism ...
... determine the dominant mechanism by ruling out the other mechanisms through their parametric dependence or lack thereof. Experimentally, this is crucial to the identification of an unknown mechanism. In a certain region of parameter space, all the dependencies must be accounted for by this mechanism ...
SN65HVD11-HT 数据资料 dataSheet 下载
... Minimum and maximum parameters are characterized for operation at TA = 175°C but may not be production tested at that temperature. Production test limits with statistical guardbands are used to ensure high temperature performance. Minimum and maximum parameters are characterized for operation at TA ...
... Minimum and maximum parameters are characterized for operation at TA = 175°C but may not be production tested at that temperature. Production test limits with statistical guardbands are used to ensure high temperature performance. Minimum and maximum parameters are characterized for operation at TA ...
Applications of Circuits
... clear to you, a mountain river can be used to model an electric circuit. From its source high in the mountains, the river flows downhill to the plains below. No matter which path the river takes, its change in elevation, from the mountaintop to the plain, is the same. Some rivers flow downhill in a ...
... clear to you, a mountain river can be used to model an electric circuit. From its source high in the mountains, the river flows downhill to the plains below. No matter which path the river takes, its change in elevation, from the mountaintop to the plain, is the same. Some rivers flow downhill in a ...
Photodiode Characteristics and Applications Photodiode
... room temperature. This is the gap between the valence band and the conduction band. At absolute zero temperature the valence band is completely filled and the conduction band is vacant. As the temperature increases, the electrons become excited and escalate from the valence band to the conduction ba ...
... room temperature. This is the gap between the valence band and the conduction band. At absolute zero temperature the valence band is completely filled and the conduction band is vacant. As the temperature increases, the electrons become excited and escalate from the valence band to the conduction ba ...
MAX6695/MAX6696 Dual Remote/Local Temperature Sensors with SMBus Serial Interface General Description
... When the remote-sensing diode is a discrete transistor, its collector and base must be connected together. Table 1 lists examples of discrete transistors that are appropriate for use with the MAX6695/MAX6696. The transistor must be a small-signal type with a relatively high forward voltage; otherwis ...
... When the remote-sensing diode is a discrete transistor, its collector and base must be connected together. Table 1 lists examples of discrete transistors that are appropriate for use with the MAX6695/MAX6696. The transistor must be a small-signal type with a relatively high forward voltage; otherwis ...
National Semiconductor Temperature Sensor Handbook
... When functionality requirements are more involved (for example if multiple trip points or analog-to-digital conversion are necessary), external circuitry and cost increase quickly. Consequently, you’ll typically use lowcost thermistors only in applications with minimal functionality requirements. T ...
... When functionality requirements are more involved (for example if multiple trip points or analog-to-digital conversion are necessary), external circuitry and cost increase quickly. Consequently, you’ll typically use lowcost thermistors only in applications with minimal functionality requirements. T ...
Lumped element model
The lumped element model (also called lumped parameter model, or lumped component model) simplifies the description of the behaviour of spatially distributed physical systems into a topology consisting of discrete entities that approximate the behaviour of the distributed system under certain assumptions. It is useful in electrical systems (including electronics), mechanical multibody systems, heat transfer, acoustics, etc.Mathematically speaking, the simplification reduces the state space of the system to a finite dimension, and the partial differential equations (PDEs) of the continuous (infinite-dimensional) time and space model of the physical system into ordinary differential equations (ODEs) with a finite number of parameters.