• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Definitions for Electric Service
Definitions for Electric Service

... Fault Current refers to the amount of electrical current that can be supplied to customer's equipment in the event of a fault. Customer equipment must have an AIC (available interrupting current) rating able to withstand this current. ...
Electrical safety mgmc
Electrical safety mgmc

... Any conducting part of Class I equipment accessible to the user, such as the metal casing, is connected to earth by an earth wire. This wire becomes the third pin of the plug connecting the equipment to the mains ...
S03 Editors Report - Raleigh
S03 Editors Report - Raleigh

... Editor’s Report – Spring 2003 Raleigh Meeting Between October 2002 and April 2003, a total of (34) papers and in the transformer area were submitted to IEEE Transactions on Power Delivery (20 new, 14 revised). During this time (21) reviews were completed and (13) reviews are in-progress. For complet ...
Question Bank
Question Bank

... d. Independent of shape 9. The sending end voltage of a feeder with ...
Week 1 - Transformer
Week 1 - Transformer

... electric power systems. • matching source and load impedances for maximum power transfer in electronic and control circuitry. • electrical isolation (isolating one circuit from another or isolating dc while maintaining ac continuity between two circuits). ...
Unit-8Lecture 52 TESTING OF CABLES Cables are very important
Unit-8Lecture 52 TESTING OF CABLES Cables are very important

... Partial discharge tests on the windings are done to assess the discharge magnitudes and the radio interference levels (see also Sec. 10.6). The transformer is connected in a manner similar to any other equipment (see Sec. 9.4) and the discharge measurements are made. The location of the fault or voi ...
Transformers
Transformers

... There are huge transformers in towns and cities where the highvoltage electricity from incoming power lines is converted into lower-voltages. There are transformers in your home as well. Electric appliances such as washing machines and dishwashers use voltages of 110-240 volts, but electronic device ...
Electronic Devices and Circuits Lecture 2
Electronic Devices and Circuits Lecture 2

...  In the past, the distribution system contains 80% of total investment.  Figure 1.1 shows Electrical utility plants in service for the years 1960 to 1978.  Total operation and maintenance (O&M) costs for the privately owned utilities have increased from $ 8.3 billion in 1969 to $ 40.2 billion in ...
TD class note 3
TD class note 3

... at a given efficiency of transmission. Thus for the same power transmitted P, same losses P L and same peak voltage V,we can determine the reduction of conductor cross-section. (b) Use of Ground Return Possible In the case of hvdc transmission, ground return (especially submarine crossing) may be us ...
Lecture note from 21-26 Lecture 21 Problem Solving 1) A single
Lecture note from 21-26 Lecture 21 Problem Solving 1) A single

... at a given efficiency of transmission. Thus for the same power transmitted P, same losses PL and same peak voltage V,we can determine the reduction of conductor cross-section. (b) Use of Ground Return Possible In the case of hvdc transmission, ground return (especially submarine crossing) may be use ...
29477 Demonstrate knowledge of the New Zealand national
29477 Demonstrate knowledge of the New Zealand national

... Using fully labelled diagrams explain the New Zealand electricity generation, transmission, and distribution system from power station to consumer. Range ...
Chapter 11.1 & 11.2
Chapter 11.1 & 11.2

... An aside: The earth as a magnet • The earth has a magnetic field. Earth acts like a huge magnet in which the south pole of the earth’s magnet is north. (North pole of a compass needle points towards it.) • Magnetic poles are not at geographic poles, magnetic north pole is in Northern Canada. It mov ...
Unit 27 Single-Phase Transformers
Unit 27 Single-Phase Transformers

... • This is an isolation transformer. The secondary winding is physically and electrically isolated from the primary winding. ...
Slides
Slides

... Source: Tom Ernst, Minnesota Power ...
Single phase Transformer
Single phase Transformer

... • This is an isolation transformer. The secondary winding is physically and electrically isolated from the primary winding. ...
How Does a Generator Work?
How Does a Generator Work?

... higher voltage than the other two. This is sometimes referred to as “The Wild Leg.”. In the diagram below the L0 connection (neutral) will typically be 120 volts between L0 and L1 and between L0 and L2. The voltage across L0 and L3 will be approximately 190 volts. In generator systems that have an a ...
A-Flame Corporation
A-Flame Corporation

... The CV power supply provides flat constant potential volt/ampere characteristics, with a continuous open circuit voltage control. The power supply characteristics were developed exclusively for metal spraying. These features provide not only maximal arc stability, but also hold noise emissions durin ...
Slides - Course Website Directory
Slides - Course Website Directory

... Used where higher service reliability is required Generally more expensive than radial systems Feeder conductors are sized to feed entire loop Loop systems can be used in underground residential distribution (URD), where faults are infrequent but are usually permanent ...
Controlled Short Circuit GMAW Process Surpasses SMAW, GTAW
Controlled Short Circuit GMAW Process Surpasses SMAW, GTAW

... • The techniques for welding carbon are the same for stainless alloys • To qualify procedures for welding 300 series stainless steel piping – Without backing gas, fabricators should do the following: 1.) Ensure a minimum 1/8” gap around the entire circumference of the joint. This gap allows the shie ...
Step-up Transformers - Pacific Crest Transformers
Step-up Transformers - Pacific Crest Transformers

... commercial, and residential loads. As such they step voltage down from a distribution level (typically 35 kV or lower) to 600 V class. Conventional distribution transformer construction is adequate since loading tends to vary modestly over the life of the transformer. This paper will explore the loa ...
INTRODUCTION TO T&T WIRING CODE
INTRODUCTION TO T&T WIRING CODE

... • Requires that every new installation and any alteration to an existing installation shall be inspected and tested to ensure compliance with TTS 171 ...
xp iecex transformers flyer
xp iecex transformers flyer

... Eaton’s Crouse-Hinds series IECEx Dry-Type Transformers are designed to operate where volatile flammable liquids or gases are handled, processed or used, and where ignitable concentrations of gases or vapors are normally prevented by positive mechanical ventilation, such as: • Refineries • Che ...
Trouble shooting Transformers or Transformers with Dimmer circuits.
Trouble shooting Transformers or Transformers with Dimmer circuits.

... You can return it to Jacobs Online for testing at your expense if you choose but because they are fully tested before being shipped, there are only two possibilities, 1) they are still in good working condition and you have not hooked them up right or have not tested them correctly, in which case yo ...
DET62D Three-Terminal Ground Resistance Tester
DET62D Three-Terminal Ground Resistance Tester

... Three-Terminal Ground Resistance Tester Earth testing kits including suitable test spikes and leads and a book describing several testing techniques entitled “Getting Down to Earth” are also available. ...
High Current Test Sets - agea
High Current Test Sets - agea

... Either current or temperature controlled, allow these test sets long duration current and temperature investigations on current bars, connectors, contactors, power breakers, isolators, bushings and power cables. The measured temperatures and currents are stored in a data logger or by a sophisticated ...
< 1 ... 61 62 63 64 65 66 67 68 69 ... 79 >

Single-wire earth return



Single wire earth return (SWER) or single wire ground return is a single-wire transmission line which supplies single-phase electrical power from an electrical grid to remote areas at low cost. Its distinguishing feature is that the earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. It is also used for high-voltage DC over submarine power cables. Electric single-phase railway traction, such as light rail uses a very similar system. It uses resistors to earth to reduce hazards from rail voltages, but the primary return currents are through the rails.