• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Ground Fault Interrupter
Ground Fault Interrupter

... In the event of an electrical fault which brings dangerous high voltage to the case of an appliance, you want the circuit breaker to trip immediately to remove the hazard. If the case is grounded, a high current should flow in the appliance ground wire and trip the breaker. That's not quite as simp ...
MOV Arresters Limit Overvoltage on 138 kV Underground
MOV Arresters Limit Overvoltage on 138 kV Underground

... exist for about two seconds. The initially used conventional arresters Silicon Carbide had to be sized large enough to withstand this two-per-unit 60 Hertz voltage without sparkover. This resulted in what became an unacceptably high overvoltage on the solid dielectric cable (2.1 p.u.). At least one ...
Chapter 24 Three-Phase Voltage Generation
Chapter 24 Three-Phase Voltage Generation

... Phase voltages Voltages across phases For a Y load, phases are from line to neutral For load, the phases are from line to line ...
OSM_Al_2 Series Recloser
OSM_Al_2 Series Recloser

... The outdoor switching module (OSM) is designed for use as an automatic circuit recloser or a sectionalizer on overhead distribution lines and as an outdoor switching module in distribution substation applications for voltages up to 27 kV. ...
Digital Knight Dual Voltage Heater Conversion Instructions
Digital Knight Dual Voltage Heater Conversion Instructions

... Converting the Heat Platen Voltage: 1. Disconnect the heat platen from the frame of the press. 2. Remove the top cover of the heat platen, and loosen the cable clamp so the wires can pass through the heat platen cover freely. 3. There are three female plug connections labeled 1, 2 and 3 on the heati ...
AC/DC Power Conversion System Using 3/9 Multiphase
AC/DC Power Conversion System Using 3/9 Multiphase

... induction between two circuits linked by a common magnetic flux. It is often used to raise or lower voltage and also for impedance transformation. The transformer is an important element in the development of high-voltage electric power transmission. Transformers can be classified into various types ...
THREE PHASE TRANSFORMERS
THREE PHASE TRANSFORMERS

... power system, Δ-Δ connection schemes are preferred because of the inherent reliability of the Δ configuration. Considering that a Δ configuration can operate satisfactorily missing one winding, some power system designers choose to create a three-phase transformer bank with only two transformers, r ...
009irrigationwiringnoreviewquestions
009irrigationwiringnoreviewquestions

... p and Usingg size 14 wire, an inrush current of 0.4 amps, 3-V allowable loss, the allowable distance between the valve and controller is: ...
Equipotentials
Equipotentials

... One probe of the voltmeter should be connected to or held against a chosen reference point, for example one of the electrodes. The other probe is moved around the surface of the paper to find points of equipotential. The students should map out several lines of equipotential. They can then sketch th ...
Chapter 23:Three
Chapter 23:Three

... • Phase voltages – Voltages across phases • For a Y load, phases are from line to neutral • For  load, the phases are from line to line ...
Equipotentials
Equipotentials

... One probe of the voltmeter should be connected to or held against a chosen reference point, for example one of the electrodes. The other probe is moved around the surface of the paper to find points of equipotential. The students should map out several lines of equipotential. They can then sketch th ...
Current Transformers
Current Transformers

... Desired ratio - primary current and secondary current (For example 500A/5A) Centre hole in the transformer/Dimension of the primary conductor - will a rail or cable be used? (Example: Rail 10x50mm or ID>50mm) Desired burden (power) (VA) and accuracy class (Example: 20 VA cl. 0.5 (see IEC 60044-1)) O ...
GROUNDING AND NOISE
GROUNDING AND NOISE

... As you can see by the material that has been covered, AC power contains more than just that pure mythical 60 Hz sine wave that you read about in text books. In most cases, filters added to the power line add noise of their own. The capacitors in the filter circuit leak current into the ground system ...
Period 14 Activity Sheet:  Electrical Safety and Transmission
Period 14 Activity Sheet: Electrical Safety and Transmission

... the multimeter leads in the water. Set the digital multimeter to read DC voltage. ...
Full_wave_rectifier_transformer
Full_wave_rectifier_transformer

... the load or to invert one polarity of the ac signal at the load. If a voltage regulator is not included, the dc signal is said to be unregulated. This means that there is an artifact from the ac signal on top of the dc signal, which is known as the ripple voltage. Half-wave rectifiers are the least ...
Transmission of electrical power
Transmission of electrical power

... is fixed once its diameter has been chosen, the only other way to reduce power loss is to reduce the current I going through the cable. Since P = VI, if we want to minimize I we can do so if we increase V, thus maintaining the power P that is to be delivered. This is the idea behind the use of the ...
Non-K-Factor Dry-Type Transformers
Non-K-Factor Dry-Type Transformers

... waffle at each corner of the transformer, sized for load of 50 pounds per square inch. 2. For wall hung transformer installations (15kVA and less), use spring type Korfund Series P. Provide sound pads at each corner of the transformer sized for ½ inch deflection. Securely anchor wall-mounting bracke ...
36 - BSNL Durg SSA(Connecting India)
36 - BSNL Durg SSA(Connecting India)

... across the earth connection is low. If any current flows through the service earthing system, a potential difference will be developed across the earth connection. This can introduce interference in the form of electrical noise into any telecommunication circuit connected to that earthing system. Th ...
STUDY OF TRANSIENT CHARACTERISTICS
STUDY OF TRANSIENT CHARACTERISTICS

... Summary of Doctor Engineering Thesis ...
Transformers - WordPress.com
Transformers - WordPress.com

...  It transfers electrical energy from one electrical circuit to other with desired change in voltage and current, without changing the frequency(f=50Hz) and power.  Constant flux device  Magnetically coupled and electrically isolated ...
SRI KRISHNA ENGINEERING COLLEGE
SRI KRISHNA ENGINEERING COLLEGE

... 2. Draw and define impulse voltage wave shape and mention it’s specification as per standards. 3. Define the uniform and non-uniform field. 4. A transmission line of surge impedance 250 is connected to a cable of surge impedance 50 at the other end, if a surge of 400 kV travels along the line to the ...
1 - Scope - OPS Schneider Electric
1 - Scope - OPS Schneider Electric

... metal enclosure:  either for indoor installation, with degree of protection IP 31 (except the bottom which may be IP 21),  or for outdoor installation with degree of protection IP 35 (except the bottom which may be IP 31). This outdoor installation will require some adjustments related to weather ...
turns ratio meter 4167f - Tinsley Instrumentation Ltd
turns ratio meter 4167f - Tinsley Instrumentation Ltd

... transformer. However, an external excitation using different voltages and frequencies is also possible. A special feature is the possibility to use three phase measuring voltage. Transformers have phase angles of n*30° where n is the vector number 0 to 11. Because all measurements are single phase a ...
Autotransformer
Autotransformer

... • A 400-turn autotransformer, operating in the step-down mode with a 25% tap, supplies a 4.8-kVA, 0.85 Fp lagging load. The input to the transformer is 2400-V, 60-Hz. Neglecting the small losses and leakage effects, determine – (a) the load current, – (b) the incoming line current, – (c) the transfo ...
Signal Reference Grid Wire Clamp
Signal Reference Grid Wire Clamp

... WIRE SIZE ...
< 1 ... 55 56 57 58 59 60 61 62 63 ... 79 >

Single-wire earth return



Single wire earth return (SWER) or single wire ground return is a single-wire transmission line which supplies single-phase electrical power from an electrical grid to remote areas at low cost. Its distinguishing feature is that the earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. It is also used for high-voltage DC over submarine power cables. Electric single-phase railway traction, such as light rail uses a very similar system. It uses resistors to earth to reduce hazards from rail voltages, but the primary return currents are through the rails.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report