• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TTR 795 - Haefely Hipotronics
TTR 795 - Haefely Hipotronics

... measured. During production and also in the field the TTR2796 is a highly valued diagnostic instrument. Within half a minute after connecting the measurement cables to the terminals of the transformer, the voltage ratio, turns ratio, ratio deviation, excitation current and phase ...
Industrial Power System Design in a Utility Environment
Industrial Power System Design in a Utility Environment

... There are a limited number of transmission voltage (69 or 138 kV) lines in the area of operations. The high cost voltage drop necessitates a larger conductor than would of constructing both new transmission lines and trans- normally be necessary for this size load. The above-mentioned constraints re ...
Grounding Explained by Greg KB4VVE
Grounding Explained by Greg KB4VVE

... wire. Bond using an approved clamp such as a ‘split bolt’. Soldering is allowed, but only in addition to a proper mechanical connection. A good low impedance ground rod system for the shack consists of multiple rods 8 – 16 feet apart, connected together, bonded externally to electrical entrance grou ...
LP Series Installation - Total Protection Solutions
LP Series Installation - Total Protection Solutions

... All LowProfile units come standard with one set of Form “C” dry relay contacts for the SPD status. These contacts are for connection to a user-provided remote alarm and monitoring circuit. The relay contacts are rated 65VDC/150VAC with maximum switching power of 30WDC/60VA AC. See Figure 5 for the f ...
Development of an IEC Standard - transformer
Development of an IEC Standard - transformer

... Superconducting transformer uses high temperature superconducting materials (HTS) which need to be cooled to the temperature of about minus 200°C. Prototypes and single applications for non distribution business are nothing new. China's Institute of Electrical Engineering have lately demonstrated a ...
Transformer - KFUPM Faculty List
Transformer - KFUPM Faculty List

... Speaking of protection, the majority of transformers have inherent protection for the secondary through a fuse or thermal link. The fuse may or may not be easily replaceable. When installing transformers, if there is any doubt, at the least install secondary fusing to protect the transformer and/or ...
I 2
I 2

... Voltage Control The allowable voltage variation at the customer load point is usually ± 5% of the rated (nominal) value. Control measures are taken to maintain the voltage within the limits. - Use of transformer tap changers: on-load/off-load - Injecting reactive power (Vars): series/shunt compensa ...
experiment 5 - UniMAP Portal
experiment 5 - UniMAP Portal

... it equals the voltage across either winding (EAB and EBC). The third winding is then connected in series, and the voltage across the series combination of the three windings is measured to confirm that it is zero before delta is closed, as shown in Figure 5-4 (b). This is extremely important for a d ...
Specification Number
Specification Number

... H. IEEE C57.12.59 - Guide for Dry-Type Transformer Through-Fault Current Duration I. IEEE C57.12.70 - Terminal Markings and Connections for Distribution and Power Transformers J. IEEE C57.12.80 - Standard Terminology for Power and Distribution Transformers K. IEEE C57.12.91 - Test Code for Dry-T ...
A NOVEL HYBRID DSTATCOM TOPOLOGY FOR LOAD
A NOVEL HYBRID DSTATCOM TOPOLOGY FOR LOAD

... DSTATCOM are connected) such that the harmonic filtering, power factor correction, and load balancing can be achieved. The distribution static compensator (DSTATCOM) is used for load compensation in power distribution network. A new topology for DSTATCOM applications with non-stiff source is propose ...
A NOVEL HYBRID DSTATCOM TOPOLOGY FOR LOAD
A NOVEL HYBRID DSTATCOM TOPOLOGY FOR LOAD

... DSTATCOM are connected) such that the harmonic filtering, power factor correction, and load balancing can be achieved. The distribution static compensator (DSTATCOM) is used for load compensation in power distribution network. A new topology for DSTATCOM applications with non-stiff source is propose ...
1 Conductors and Insulators Tutorial Cornerstone Electronics
1 Conductors and Insulators Tutorial Cornerstone Electronics

... wire - it allows them to safely carry more power with less of that power being dissipated as heat. Almost all automotive wiring is stranded while almost all house wiring is solid. Burn #30 ga in series with # 18 ga wire using three motors in parallel. Conductor Sizes:  American Wire Gauge (AWG): A ...
doc - Cornerstone Robotics
doc - Cornerstone Robotics

... wire - it allows them to safely carry more power with less of that power being dissipated as heat. Almost all automotive wiring is stranded while almost all house wiring is solid. Burn #30 ga in series with # 18 ga wire using three motors in parallel. Conductor Sizes:  American Wire Gauge (AWG): A ...
experiment 5 - UniMAP Portal
experiment 5 - UniMAP Portal

... it equals the voltage across either winding (EAB and EBC). The third winding is then connected in series, and the voltage across the series combination of the three windings is measured to confirm that it is zero before delta is closed, as shown in Figure 5-4 (b). This is extremely important for a d ...
Cookbook for Do-it-yourself Transformer Design
Cookbook for Do-it-yourself Transformer Design

... wire evenly across the bobbin. This also applies to high turn, multilayered windings where the last layer does not entirely fill the bobbin. Minimize the number of layers of wire to reduce leakage inductance and eddy current losses. Pinout – A number of factors will affect the bobbin pinout, includi ...
Illumination Utilization of Electrical Energ 6TH SEMESTER
Illumination Utilization of Electrical Energ 6TH SEMESTER

... Therefore the two windings should be closed to each other to reduce the secondary winding leakage reactance. ...
Earth Leakage Problem of Superconductor Magnet System at TLS
Earth Leakage Problem of Superconductor Magnet System at TLS

... 1) Employing power supplies with isolated I/O buffers built-inside or 2) Feeding the DAC/ADC I/O to an isolation board which converts the single-ended signals into differential signal pairs and then connecting the differential pairs to the power supplies. Strategy 2 is used here to cut the ground lo ...
Appalachian Power Safety Policy No. 22
Appalachian Power Safety Policy No. 22

... wear a minimum of Class 2 rubber gloves and those working from the pole shall also wear rubber overshoes. Workers on the ground handling de-energized and grounded conductors or anything (such as a service drop or guy wire) bonded to those conductors shall wear a minimum of Class 2 rubber gloves and ...
SI99-01 - Semtech
SI99-01 - Semtech

... between the power and ground of vulnerable components. The bypass capacitors serve to reduce charge injection and thus the voltage differential between power and ground. The TVS diverts induced currents and maintains the voltage differential at the level of the clamping voltage of the TVS. The TVS a ...
Three Phase Transformers
Three Phase Transformers

... For practical calculations, it is reasonable to model the three-phase transformer as three ideal transformers as shown in Figure 2. Since these transformers are ideal, the secondary voltages are related to the primary voltages by the turns ratio according to N Vˆ2 a = 2 Vˆ1a N1 ...
GG2310881094
GG2310881094

... more and more restrictions on current total harmonic the neutral of three-phase series transformer to connect a distortion (THD) limits, drawn by nonlinear loads, to neutral wire to realize the 3P4W system, then 3P4W control the power distribution system harmonic system can easily be achieved from a ...
Cct component
Cct component

... •Power due to eddy current •Power via flux leakages. ...
CO21579585
CO21579585

... factor correction modes of operation of the DSTATCOM have been observed and are as expected. The dc bus voltage of the DSTATCOM has been regulated to the reference dc bus voltage under all varying loads. The total kilovolt amperes rating of the T-connected transformer is lower than a star/delta tran ...
Position Paper on IEEE Task Force on Insulator Icing Test
Position Paper on IEEE Task Force on Insulator Icing Test

... which reduces the harmonic content of the output voltage. In addition, the gapped core represents an inductive load which compensates 8-10% of a rated capacitive load. • Thoma type variable transformers comply with the heavy duty requirements. ...
Document
Document

... building power distribution systems without making physical contact with the equipment to be tested. ...
< 1 ... 45 46 47 48 49 50 51 52 53 ... 79 >

Single-wire earth return



Single wire earth return (SWER) or single wire ground return is a single-wire transmission line which supplies single-phase electrical power from an electrical grid to remote areas at low cost. Its distinguishing feature is that the earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. It is also used for high-voltage DC over submarine power cables. Electric single-phase railway traction, such as light rail uses a very similar system. It uses resistors to earth to reduce hazards from rail voltages, but the primary return currents are through the rails.