
Impulse generators used for testing low-voltage equipment
... 4.1 Impulse generators with a defined voltage waveform ...................................................................... 4 4.2 Impulse generators with a defined current waveform....................................................................... 5 4.3 Impulse generators with defined voltage ...
... 4.1 Impulse generators with a defined voltage waveform ...................................................................... 4 4.2 Impulse generators with a defined current waveform....................................................................... 5 4.3 Impulse generators with defined voltage ...
MAX8758 Step-Up Regulator with Switch Control and Operational Amplifier for TFT LCD
... The MAX8758 includes a high-performance step-up regulator, a high-speed operational amplifier, and a logiccontrolled, high-voltage switch-control block with programmable delay. The device is optimized for thin-film transistor (TFT) liquid-crystal display (LCD) applications. The step-up DC-DC regulat ...
... The MAX8758 includes a high-performance step-up regulator, a high-speed operational amplifier, and a logiccontrolled, high-voltage switch-control block with programmable delay. The device is optimized for thin-film transistor (TFT) liquid-crystal display (LCD) applications. The step-up DC-DC regulat ...
Chapter 18 Powerpoint
... Inductors react against changes in current by consuming or providing voltage in a polarity necessary to oppose the change When an inductor is faced with an increasing current, it acts as a load, by consuming voltage. (series opposing) When an inductor is faced with a decreasing current, it acts as a ...
... Inductors react against changes in current by consuming or providing voltage in a polarity necessary to oppose the change When an inductor is faced with an increasing current, it acts as a load, by consuming voltage. (series opposing) When an inductor is faced with a decreasing current, it acts as a ...
A Novel Second-Order All-Pass Filter Using Square
... translinear circuits. These filters use the idea of the companding signal processing method [5], [6]. This feature uses the nonlinear current-to-voltage characteristics of MOS or bipolar transistors in order to achieve reduced voltage swings at internal nodes, thus allowing large dynamic ranges at l ...
... translinear circuits. These filters use the idea of the companding signal processing method [5], [6]. This feature uses the nonlinear current-to-voltage characteristics of MOS or bipolar transistors in order to achieve reduced voltage swings at internal nodes, thus allowing large dynamic ranges at l ...
Triple, Low-Power, High-Speed, Fixed-Gain
... This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete devi ...
... This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete devi ...
OPA683 Very Low-Power, Current Feedback OPERATIONAL AMPLIFIER With Disable FEATURES
... demanding requirements of studio cameras and broadcast video. The output capability for the OPA683 also sets a new mark in performance for very low-power current feedback amplifiers. Delivering a full ±4VPP swing on ±5V supplies, the OPA683 also has the output current to support this swing into a 10 ...
... demanding requirements of studio cameras and broadcast video. The output capability for the OPA683 also sets a new mark in performance for very low-power current feedback amplifiers. Delivering a full ±4VPP swing on ±5V supplies, the OPA683 also has the output current to support this swing into a 10 ...
SWE-94-U - Metrix Electronics
... exceed the recommended values. In such cases forced cooling of the unit must be considered (e.g. by using a ventilator). ...
... exceed the recommended values. In such cases forced cooling of the unit must be considered (e.g. by using a ventilator). ...
Topics - Ibiblio
... students often mix contexts of voltage, current, and resistance. Whenever you use any equation describing a physical phenomenon, be sure that each variable of that equation relates to the proper real-life value in the problem you’re working on solving. For example, when calculating the current throu ...
... students often mix contexts of voltage, current, and resistance. Whenever you use any equation describing a physical phenomenon, be sure that each variable of that equation relates to the proper real-life value in the problem you’re working on solving. For example, when calculating the current throu ...
Q3 2009 Issue Analog Applications Journal
... Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware prod ...
... Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware prod ...
DAC1280 - Texas Instruments
... modulated bitstream. The DAC1280 output is a differential current intended for use with an active I/V converter. The I/V converter provides a voltage output suitable for performance testing of sensors and ADCs. Three gain control pins set the output range in 6dB steps from 0dB to –36db (±2.5V to ±0. ...
... modulated bitstream. The DAC1280 output is a differential current intended for use with an active I/V converter. The I/V converter provides a voltage output suitable for performance testing of sensors and ADCs. Three gain control pins set the output range in 6dB steps from 0dB to –36db (±2.5V to ±0. ...
Low-Power, Current Feedback Operational Amplifier With Disable
... power line drivers to meet the demanding requirements of studio cameras and broadcast video. The output capability of the OPA684 also sets a new mark in performance for low-power current feedback amplifiers. Delivering a full ±4VPP swing on ±5V supplies, the OPA684 also has the output current to sup ...
... power line drivers to meet the demanding requirements of studio cameras and broadcast video. The output capability of the OPA684 also sets a new mark in performance for low-power current feedback amplifiers. Delivering a full ±4VPP swing on ±5V supplies, the OPA684 also has the output current to sup ...
M194 High Resistance Decade
... and resistance ranges of safety testers, HIPOTs etc. It can be used for calibration of any DC high resistance meter with working voltage up to 6 kV. M194 is based on programmable series high resistance decade box which is completed with additional electronic circuits allowing measurement of test vol ...
... and resistance ranges of safety testers, HIPOTs etc. It can be used for calibration of any DC high resistance meter with working voltage up to 6 kV. M194 is based on programmable series high resistance decade box which is completed with additional electronic circuits allowing measurement of test vol ...
Full-Text PDF
... displacement sensor based on the inductive concept was described in [4], using a copper meander coil and pattern guide made from a soft iron. A hydrogel-based passive wireless sensor with a micromachined inductive transducer was investigated in [5], but it was not a position sensor and the sensor wa ...
... displacement sensor based on the inductive concept was described in [4], using a copper meander coil and pattern guide made from a soft iron. A hydrogel-based passive wireless sensor with a micromachined inductive transducer was investigated in [5], but it was not a position sensor and the sensor wa ...
O? Control v|_
... tion circuit, Wherein the ?rst time constant is larger than the second time constant When the ?rst voltage is smaller than the second voltage, and vice versa. If appropriate sWitching means ensure at a particular instant that the capacitors can ...
... tion circuit, Wherein the ?rst time constant is larger than the second time constant When the ?rst voltage is smaller than the second voltage, and vice versa. If appropriate sWitching means ensure at a particular instant that the capacitors can ...
selecting and using transducers for the measurement of electric
... These transformers are most often the 'donut' type. The current carrying conductor is passed through the opening or window of the 'donut.' The secondary winding of the current transformer is wound by the manufacturer on the toroidal iron core which makes the 'donut' shape. On most North American man ...
... These transformers are most often the 'donut' type. The current carrying conductor is passed through the opening or window of the 'donut.' The secondary winding of the current transformer is wound by the manufacturer on the toroidal iron core which makes the 'donut' shape. On most North American man ...
Multimeter
A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.