
CN0202: 灵活、高精度、低漂移的PLC/DCS模拟输出模块SigmaDSP音频处理器的接口
... the industrial control environment can subject I/O circuits to much higher transients. External 30 V, 600 W transient voltage suppressors (TVS), a 50 mA, 30 V PolySwitch, and power Schottky diodes are built into the EVAL-CN0202-SDPZ circuit board to provide higher voltage ESD protection, 50 mA overc ...
... the industrial control environment can subject I/O circuits to much higher transients. External 30 V, 600 W transient voltage suppressors (TVS), a 50 mA, 30 V PolySwitch, and power Schottky diodes are built into the EVAL-CN0202-SDPZ circuit board to provide higher voltage ESD protection, 50 mA overc ...
Resistor Lab Review (2.8MB ppt)
... • Multimeters are instruments that are used to measure voltage, resistance, and currents. – Fancier models can also check chips, diodes, capacitors, continuity and measure temperature. ...
... • Multimeters are instruments that are used to measure voltage, resistance, and currents. – Fancier models can also check chips, diodes, capacitors, continuity and measure temperature. ...
Digital Thermometer
... approximately 180K ohms at freezing to 2.5K at boiling. When connected in series with a 180 K ohm fixed resistor, the output voltage as a function of the thermistor resistance (or the temperature), is: (V+) 180K Vout = --------------------Rth + 180K This is the voltage divider equation. Vout is conn ...
... approximately 180K ohms at freezing to 2.5K at boiling. When connected in series with a 180 K ohm fixed resistor, the output voltage as a function of the thermistor resistance (or the temperature), is: (V+) 180K Vout = --------------------Rth + 180K This is the voltage divider equation. Vout is conn ...
MV-7 Current Transformer
... that produces a compact, neat and rugged transformer selected for its high dielectric and mechanical strength, moisture resistance and excellent thermal conductivity. The outer shell is injection-molded lexan. ...
... that produces a compact, neat and rugged transformer selected for its high dielectric and mechanical strength, moisture resistance and excellent thermal conductivity. The outer shell is injection-molded lexan. ...
rc-rl lect
... • ZC is measured in ohms and is a measure of how much the capacitive element will “control or impede” the level of current through the network. • This format like the one for the resistive element, will prove to be a useful “tool” in the analysis of ac networks. • Be aware that ZC is not a phasor qu ...
... • ZC is measured in ohms and is a measure of how much the capacitive element will “control or impede” the level of current through the network. • This format like the one for the resistive element, will prove to be a useful “tool” in the analysis of ac networks. • Be aware that ZC is not a phasor qu ...
Model 6514 Electrometer Specifications
... INPUT BIAS CURRENT NOISE: <750aA p-p (capped input), 0.1Hz to 10Hz bandwidth, damping on. Digital filter = 40 readings. INPUT VOLTAGE BURDEN at TCAL ±1°C (user adjustable): <20µV on 20pA, 2nA, 20nA, 2µA, 20µA ranges. <100µV on 200pA, 200nA, 200µA ranges. <2mV on 2mA range. <4mV on 20mA range. TEMPER ...
... INPUT BIAS CURRENT NOISE: <750aA p-p (capped input), 0.1Hz to 10Hz bandwidth, damping on. Digital filter = 40 readings. INPUT VOLTAGE BURDEN at TCAL ±1°C (user adjustable): <20µV on 20pA, 2nA, 20nA, 2µA, 20µA ranges. <100µV on 200pA, 200nA, 200µA ranges. <2mV on 2mA range. <4mV on 20mA range. TEMPER ...
Phys 345 Electronics for Scientists
... defined, use the same convention in every loop.Voltage across a resistor is +’ve if voltage direction the same as current ...
... defined, use the same convention in every loop.Voltage across a resistor is +’ve if voltage direction the same as current ...
AC/DC Current Probe Model SL206 Features
... The Model SL206 is designed for AC/DC current measurement capabilities using Hall effect technology. It measures from a few mA to over 100A. The “screw driver” shape, with its narrow elongated prod, was chosen to permit probing in crowded cable bundles, or measuring in tight areas such as on circuit ...
... The Model SL206 is designed for AC/DC current measurement capabilities using Hall effect technology. It measures from a few mA to over 100A. The “screw driver” shape, with its narrow elongated prod, was chosen to permit probing in crowded cable bundles, or measuring in tight areas such as on circuit ...
Slide 1
... • In a parallel circuit, electrons only have to move through the loads that are in their paths • That means that each electron only has to give up energy to the load in their path • Each electron gives up the same amount of energy • So the voltage of resistors parallel to each other are equal to eac ...
... • In a parallel circuit, electrons only have to move through the loads that are in their paths • That means that each electron only has to give up energy to the load in their path • Each electron gives up the same amount of energy • So the voltage of resistors parallel to each other are equal to eac ...
Introduction to Transformer Rated Meters
... – Meter register must show the actual primary usage values – Example: Transformer Factor is 4800 – Meter multiplies values by 4800 and displays result – A dial multiplier may be required to prevent “wrap around”, e.g. x100, x1000, etc. ...
... – Meter register must show the actual primary usage values – Example: Transformer Factor is 4800 – Meter multiplies values by 4800 and displays result – A dial multiplier may be required to prevent “wrap around”, e.g. x100, x1000, etc. ...
Written - Rose
... Firstly we need to determine the output voltage of the first op amp, which can be labeled as v1 . There is zero voltage across the two input terminals of the ideal op amp. So the inverting terminal voltage should be equal to that of the non inverting terminal. That is 2V. The input currents should b ...
... Firstly we need to determine the output voltage of the first op amp, which can be labeled as v1 . There is zero voltage across the two input terminals of the ideal op amp. So the inverting terminal voltage should be equal to that of the non inverting terminal. That is 2V. The input currents should b ...
9_EMBEDDED_GR_ppapag_ADC
... (encoded with discrete binary values) for processing • Analog to Digital Converters (ADC or A/D) convert continuous analog signals to discrete digital numbers – allowing digital electronics to sample real world signals • ADC’s are ‘Mixed Signal Devices’ as they combine analog circuits with DSP • Rev ...
... (encoded with discrete binary values) for processing • Analog to Digital Converters (ADC or A/D) convert continuous analog signals to discrete digital numbers – allowing digital electronics to sample real world signals • ADC’s are ‘Mixed Signal Devices’ as they combine analog circuits with DSP • Rev ...
Science 14 Lab 3 - DC Circuits Theory All DC circuit analysis (the
... A "multimeter" is a variable-range voltmeter and ammeter, which will be used to measure the voltages and currents in this experiment. A perfect voltmeter would have infinite resistance (draw zero current) and a perfect ammeter would have zero resistance (zero voltage drop); but a real meter has a ce ...
... A "multimeter" is a variable-range voltmeter and ammeter, which will be used to measure the voltages and currents in this experiment. A perfect voltmeter would have infinite resistance (draw zero current) and a perfect ammeter would have zero resistance (zero voltage drop); but a real meter has a ce ...
BM400/2 Series Analogue/Digital Insulation Continuity Testers
... voltage, the non-voltage measuring instruments (the BM402/2 and BM404/2), will emit a beep and the analogue arc and ‘V’ symbol will flash. On all models testing is inhibited if 55 V is detected. Hands free operation is offered as standard on all ranges except the insulation ranges. Locking and non-l ...
... voltage, the non-voltage measuring instruments (the BM402/2 and BM404/2), will emit a beep and the analogue arc and ‘V’ symbol will flash. On all models testing is inhibited if 55 V is detected. Hands free operation is offered as standard on all ranges except the insulation ranges. Locking and non-l ...
Quiz 6-2
... 2) The figure shows a simple ac circuit consisting of an inductor connected across the terminals of an ac generator. If the frequency of the ac generator is decreased by a factor of four, what will happen to the inductive reactance on the inductor? A) It decreases by a factor of four. B) It decrease ...
... 2) The figure shows a simple ac circuit consisting of an inductor connected across the terminals of an ac generator. If the frequency of the ac generator is decreased by a factor of four, what will happen to the inductive reactance on the inductor? A) It decreases by a factor of four. B) It decrease ...
6. Transient cct
... Two capacitors, C1 = 1200 pF and C2 = 2200 pF are connected in parallel. The combination is connected to an a.c voltage source VS = 155 V having a series resistor RS. After the voltage across the capacitor reach a steady state, the connection of capacitor to the battery is disconnected and discharge ...
... Two capacitors, C1 = 1200 pF and C2 = 2200 pF are connected in parallel. The combination is connected to an a.c voltage source VS = 155 V having a series resistor RS. After the voltage across the capacitor reach a steady state, the connection of capacitor to the battery is disconnected and discharge ...
Pulse_meter_project_brl4
... – Build a noninverting amplifier with a gain of 11. A high pass filter at 1 radian/sec and low pass at 100 radians/sec. Use power supply voltages of +5 and -5 volts. – Test it by connecting the input to the waveform generator and the output to the scope as shown below. – Set up the waveform generato ...
... – Build a noninverting amplifier with a gain of 11. A high pass filter at 1 radian/sec and low pass at 100 radians/sec. Use power supply voltages of +5 and -5 volts. – Test it by connecting the input to the waveform generator and the output to the scope as shown below. – Set up the waveform generato ...
Multimeter
A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.