
CISC-340 Digital Systems Everything You Need to Know
... escape the bounds of the arsenic atom and willingly take part in current flow. This material would be called N-type silicon as it would have an excess of Negative charges to participate in current flow. It doesn't take many arsenic atoms to significantly change the conductive properties of pure sili ...
... escape the bounds of the arsenic atom and willingly take part in current flow. This material would be called N-type silicon as it would have an excess of Negative charges to participate in current flow. It doesn't take many arsenic atoms to significantly change the conductive properties of pure sili ...
Kirchhoff_Laws
... positive sign of the voltage drop will be assigned to the end of R3 where current enters the resistor. As I1 is in series with R3, the direction of current through R3 is determined by the direction of current flowing out of the current source. Because I1 and R3 are in series, the magnitude of th ...
... positive sign of the voltage drop will be assigned to the end of R3 where current enters the resistor. As I1 is in series with R3, the direction of current through R3 is determined by the direction of current flowing out of the current source. Because I1 and R3 are in series, the magnitude of th ...
INT 2011 - Inside Ranken
... Use engineering notation and metric prefixes to express quantities. Convert from one metric- prefixed unit to another. ...
... Use engineering notation and metric prefixes to express quantities. Convert from one metric- prefixed unit to another. ...
3B2-Expt-B-Rev
... Extra inverters have been added to drive the LED indicators. TTL outputs have lower output resistance in the LOW-level state and a more closely defined output voltage level, which is within a few tens of millivolts relative to ground. The inverters shown in Fig. 4 are the six contained in a single ...
... Extra inverters have been added to drive the LED indicators. TTL outputs have lower output resistance in the LOW-level state and a more closely defined output voltage level, which is within a few tens of millivolts relative to ground. The inverters shown in Fig. 4 are the six contained in a single ...
an efficient conversion technique enabling utlity
... PIC micro controller, motion sensor, 555 Timer, LCD and optical encoder. A method must be utilised to reduce the high AC voltage from the LV network to the lower desired voltages. The process for the reduction of the voltage level involves three steps. Firstly, a step-down centre-tapped power transf ...
... PIC micro controller, motion sensor, 555 Timer, LCD and optical encoder. A method must be utilised to reduce the high AC voltage from the LV network to the lower desired voltages. The process for the reduction of the voltage level involves three steps. Firstly, a step-down centre-tapped power transf ...
EXERCISE #1 To measure the tripping time of maximum
... b) When performing the function of short-circuit protection, a threephase current relay will trip instantaneously (times below one second) as soon as the controlled current exceeds the set value. Current values are adjustable. Objective:- Both the values of (overload, short-circuit) current and of d ...
... b) When performing the function of short-circuit protection, a threephase current relay will trip instantaneously (times below one second) as soon as the controlled current exceeds the set value. Current values are adjustable. Objective:- Both the values of (overload, short-circuit) current and of d ...
IV Curve for semiconductor diode
... State Examination Commission – Physics Higher Level, 2012 Question 4 The following is part of a student’s report on an experiment to investigate the variation of the current I with potential difference V for a semiconductor diode. “I set up the apparatus as shown in the circuit diagram. I measured t ...
... State Examination Commission – Physics Higher Level, 2012 Question 4 The following is part of a student’s report on an experiment to investigate the variation of the current I with potential difference V for a semiconductor diode. “I set up the apparatus as shown in the circuit diagram. I measured t ...
Non-isolated Constant Current Linear LED Driver BL8312
... * Power dissipation values are based on conditions: Operating junction temperature TJ and the difference between ambient temperature TA 100 ℃. *Stress beyond above listed “Absolute Maximum Ratings” may lead permanent damage to the device. These are stress ratings only and operations of the device at ...
... * Power dissipation values are based on conditions: Operating junction temperature TJ and the difference between ambient temperature TA 100 ℃. *Stress beyond above listed “Absolute Maximum Ratings” may lead permanent damage to the device. These are stress ratings only and operations of the device at ...
Multimeter
A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.