DS2788 Stand-Alone Fuel-Gauge IC with LED Display Drivers General Description
... Battery voltage is measured at the V IN input with respect to VSS over a range of 0 to 4.5V, with a resolution of 4.88mV. The result is updated every 440ms and placed in the Voltage (VOLT) register in two’s complement form. Voltages above the maximum register value are reported at the maximum value; ...
... Battery voltage is measured at the V IN input with respect to VSS over a range of 0 to 4.5V, with a resolution of 4.88mV. The result is updated every 440ms and placed in the Voltage (VOLT) register in two’s complement form. Voltages above the maximum register value are reported at the maximum value; ...
SOLAR PV STANDARD PLAN - COMPREHENSIVE
... Minimum Conductor Size: ______ AWG Using the greater current as calculated in Method A or Method B, use Table 310.15(B)(16) to identify ac circuit conductor size. The minimum conductor ampacity shall not exceed the ampacity of chosen conductor rated at the lowest temperature rating of any connected ...
... Minimum Conductor Size: ______ AWG Using the greater current as calculated in Method A or Method B, use Table 310.15(B)(16) to identify ac circuit conductor size. The minimum conductor ampacity shall not exceed the ampacity of chosen conductor rated at the lowest temperature rating of any connected ...
MAX15066/MAX15166 High-Efficiency, 4A, Step-Down DC-DC Regulators with Internal Power Switches EVALUATION KIT AVAILABLE
... 4A with high efficiency. The devices operate from an input voltage of 4.5V to 16V and provides an adjustable output voltage from 0.606V to 90% of the input voltage. The devices are ideal for distributed power systems, notebook computers, nonportable consumer applications, and preregulation applicati ...
... 4A with high efficiency. The devices operate from an input voltage of 4.5V to 16V and provides an adjustable output voltage from 0.606V to 90% of the input voltage. The devices are ideal for distributed power systems, notebook computers, nonportable consumer applications, and preregulation applicati ...
74VCX245 Low Voltage Bidirectional Transceiver with 3.6V Tolerant Inputs and Outputs 7
... The VCX245 contains eight non-inverting bidirectional buffers with 3-STATE outputs and is intended for bus oriented applications. The T/R input determines the direction of data flow. The OE input disables both the A and B ports by placing them in a high impedance state. ...
... The VCX245 contains eight non-inverting bidirectional buffers with 3-STATE outputs and is intended for bus oriented applications. The T/R input determines the direction of data flow. The OE input disables both the A and B ports by placing them in a high impedance state. ...
Chapter 5 Using Sources and Stimuli
... Voltage and Current Controlled Elements Star-Hspice has four voltage and current controlled elements, known as E, F, G and H elements. You can use these controlled elements in Star-Hspice to model both MOS and bipolar transistors, tunnel diodes, SCRs, as well as analog functions such as operational ...
... Voltage and Current Controlled Elements Star-Hspice has four voltage and current controlled elements, known as E, F, G and H elements. You can use these controlled elements in Star-Hspice to model both MOS and bipolar transistors, tunnel diodes, SCRs, as well as analog functions such as operational ...
User`s Guide - Newport Corporation
... You or your shipping service are responsible for any shipping damage when returning the instrument to ILX Lightwave; ILX recommends you insure the shipment. If the original shipping container is not available, place your instrument in a container with at least 3 inches (7.5 cm) of compressible packa ...
... You or your shipping service are responsible for any shipping damage when returning the instrument to ILX Lightwave; ILX recommends you insure the shipment. If the original shipping container is not available, place your instrument in a container with at least 3 inches (7.5 cm) of compressible packa ...
LTM8031 - Ultralow Noise EMC 36V, 1A DC/DC uModule Regulator
... minimum recommended values for the associated operating conditions. Applying capacitor values below those indicated in Table 1 is not recommended, and may result in undesirable operation. Using larger values is generally acceptable, and can yield improved dynamic response, if it is necessary. Again, ...
... minimum recommended values for the associated operating conditions. Applying capacitor values below those indicated in Table 1 is not recommended, and may result in undesirable operation. Using larger values is generally acceptable, and can yield improved dynamic response, if it is necessary. Again, ...
Equipment Protection
... The Tri-National Standard for supplementary fuses is UL/CSA/ANCE 248-14. When supplementary overcurrent protective devices are considered for proper use, it is important (1) not to use these devices as a substitute for branch circuit protection and (2) to be sure that the device’s interrupting ratin ...
... The Tri-National Standard for supplementary fuses is UL/CSA/ANCE 248-14. When supplementary overcurrent protective devices are considered for proper use, it is important (1) not to use these devices as a substitute for branch circuit protection and (2) to be sure that the device’s interrupting ratin ...
MAX4508/MAX4509 Fault-Protected, High-Voltage Single 8-to-1/ Dual 4-to-1 Multiplexers with Output Clamps General Description
... Storage Temperature Range .............................-65°C to +160°C Lead Temperature (soldering, 10s) .................................+300°C ...
... Storage Temperature Range .............................-65°C to +160°C Lead Temperature (soldering, 10s) .................................+300°C ...
ADP2302 数据手册DataSheet 下载
... Feedback Voltage Sense Input. For the adjustable version, connect this pin to a resistive divider from VOUT. For the fixed output version, connect this pin to VOUT directly. Used for internal testing. Connect to GND or leave this pin floating to ensure proper operation. Ground. Connect this pin to t ...
... Feedback Voltage Sense Input. For the adjustable version, connect this pin to a resistive divider from VOUT. For the fixed output version, connect this pin to VOUT directly. Used for internal testing. Connect to GND or leave this pin floating to ensure proper operation. Ground. Connect this pin to t ...
a single-phase dual-output ac-dc converter with high
... Figure 4.34 Line current waveform at light load................................................ 106 ...
... Figure 4.34 Line current waveform at light load................................................ 106 ...
MAX1586A/MAX1586B/MAX1586C/MAX1587A/MAX1587C High-Efficiency, Low-I PMICs with Dynamic Core for PDAs and Smart Phones
... 60µA in Sleep Mode (Sleep LDOs On) 130µA with DC-DCs On (Core Off) 200µA All Regulators On, No Load ...
... 60µA in Sleep Mode (Sleep LDOs On) 130µA with DC-DCs On (Core Off) 200µA All Regulators On, No Load ...
PTH04T220W,
... The PTH04T220/221W includes new patent pending technologies, TurboTrans™ and SmartSync. The TurboTrans feature optimizes the transient response of the regulator while simultaneously reducing the quantity of external output capacitors required to meet a target voltage deviation specification. Additio ...
... The PTH04T220/221W includes new patent pending technologies, TurboTrans™ and SmartSync. The TurboTrans feature optimizes the transient response of the regulator while simultaneously reducing the quantity of external output capacitors required to meet a target voltage deviation specification. Additio ...
UCC28230 数据资料 dataSheet 下载
... provides 3.3-V precision reference voltages with 1.5% overall accuracy and 10-mA output current. This reference voltage can be used to supply housekeeping circuit and/or microcontroller. The precision reference voltage can also be used for accurate setting of system parameters. Other features includ ...
... provides 3.3-V precision reference voltages with 1.5% overall accuracy and 10-mA output current. This reference voltage can be used to supply housekeeping circuit and/or microcontroller. The precision reference voltage can also be used for accurate setting of system parameters. Other features includ ...
MAX5037A VRM 9.0/VRM 9.1, Dual-Phase, Parallelable, Average-Current-Mode Controller General Description
... MOSFETs, eliminating the need for external heatsinks even when delivering high output currents. Differential sensing enables accurate control of the output voltage, while adaptive voltage positioning provides optimum transient response. An internal regulator enables operation with either +5V or +12V ...
... MOSFETs, eliminating the need for external heatsinks even when delivering high output currents. Differential sensing enables accurate control of the output voltage, while adaptive voltage positioning provides optimum transient response. An internal regulator enables operation with either +5V or +12V ...
Multimeter
A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.