Evaluates: MAX1748/MAX1779 MAX1748 Evaluation Kit General Description Features
... and tested surface-mount circuit board that contains a boost switching regulator and two charge-pump voltage-regulator circuits. The boost switching circuit is configured for a +10V output that provides up to 200mA of current from a supply voltage of +2.7V to +5.5V. The positive charge-pump circuit ...
... and tested surface-mount circuit board that contains a boost switching regulator and two charge-pump voltage-regulator circuits. The boost switching circuit is configured for a +10V output that provides up to 200mA of current from a supply voltage of +2.7V to +5.5V. The positive charge-pump circuit ...
S2 Topic 4 Making Use of Electricity
... In the previous two quizzes, students were asked to write down the concept terms as indicated by the pictures shown. The focus of the two quizzes is spelling of the terms. In this ELA, the focus shifts to verbal explanations. The teacher uses the same set of slides for revision but putting greater e ...
... In the previous two quizzes, students were asked to write down the concept terms as indicated by the pictures shown. The focus of the two quizzes is spelling of the terms. In this ELA, the focus shifts to verbal explanations. The teacher uses the same set of slides for revision but putting greater e ...
Fluke Corporation Fluke 1507 Insulation Resistance Tester Manual
... been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. ...
... been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. ...
AD8591
... rail-to-rail input and output single supply amplifiers designed for low cost and high output current drive. The parts include a power saving shutdown function making the AD8591/AD8592/AD8594 op amps ideal for portable multimedia and telecom applications. Figure 29 shows the simplified schematic for ...
... rail-to-rail input and output single supply amplifiers designed for low cost and high output current drive. The parts include a power saving shutdown function making the AD8591/AD8592/AD8594 op amps ideal for portable multimedia and telecom applications. Figure 29 shows the simplified schematic for ...
Chapter 2 Motion Along a Straight Line Position, Displacement
... PRACTICE: A non-ideal voltmeter is used to measure the p.d. of the 20 k resistor as shown. What will its reading be? SOLUTION: There are two currents passing through the circuit because the voltmeter does not have a high enough resistance to prevent the green one from flowing. The 20 k resistor ...
... PRACTICE: A non-ideal voltmeter is used to measure the p.d. of the 20 k resistor as shown. What will its reading be? SOLUTION: There are two currents passing through the circuit because the voltmeter does not have a high enough resistance to prevent the green one from flowing. The 20 k resistor ...
ii. traditional z-source inverter and its modulation strategy
... These inverters can be categorized into two: isolated inverters and non-isolated inverters. For low voltage grid or power levels below 20 kW, non-isolated inverters are being used. These non-isolated inverters can again be classified into two types: Single stage inverter and two stage inverter. Sing ...
... These inverters can be categorized into two: isolated inverters and non-isolated inverters. For low voltage grid or power levels below 20 kW, non-isolated inverters are being used. These non-isolated inverters can again be classified into two types: Single stage inverter and two stage inverter. Sing ...
Lab 1 Operational Amplifiers Circuits
... program uses an analog-output channel on a DAQ card to generate DC test signals and a single analog-input channel to measure the circuit response. The LabVIEW program displays the op-amp response for each input signal and records the transfer curve on a front panel graph. The scan range, scan rate a ...
... program uses an analog-output channel on a DAQ card to generate DC test signals and a single analog-input channel to measure the circuit response. The LabVIEW program displays the op-amp response for each input signal and records the transfer curve on a front panel graph. The scan range, scan rate a ...
BDTIC ICE1HS01G Half-Bridge Resonant Controller
... This pin is connected to the collector of the optocoupler. Internally, during normal operation, this pin is connected to reference voltage source with a pull-up resistor(RFB). The IC uses the voltage on this pin to adjust the switching frequency within the range of maximum and minimum frequency set ...
... This pin is connected to the collector of the optocoupler. Internally, during normal operation, this pin is connected to reference voltage source with a pull-up resistor(RFB). The IC uses the voltage on this pin to adjust the switching frequency within the range of maximum and minimum frequency set ...
ABB Kuhlman 34500 Volt Instrument Transformers
... with burdens of B0.1 to B1.8 and up to C800 for some relay “corona free” label is bonded to the completed transformer as a applications. The transformer is accurate through its Rating guarantee of trouble-free service. Factor, and can be used continuously to this level. The LGX34-879 will operate wi ...
... with burdens of B0.1 to B1.8 and up to C800 for some relay “corona free” label is bonded to the completed transformer as a applications. The transformer is accurate through its Rating guarantee of trouble-free service. Factor, and can be used continuously to this level. The LGX34-879 will operate wi ...
Worksheet: Electric current, battery and bulb
... 4. Start measuring current and voltage. Check your bulb parameters. Turn the dial on the power supply slowly from 0V up to the maximum voltage within 10 seconds. Do not exceed the recommended maximum voltage since it can burn out the bulb. Compare your result with the prediction. Does it agree? 5. C ...
... 4. Start measuring current and voltage. Check your bulb parameters. Turn the dial on the power supply slowly from 0V up to the maximum voltage within 10 seconds. Do not exceed the recommended maximum voltage since it can burn out the bulb. Compare your result with the prediction. Does it agree? 5. C ...
ppt
... The human cardiovascular system consists of two circuits: pulmonary circulation which carries blood though the lungs, and systemic circulation which carries blood to the organs The organs of the body are connected in parallel in the systemic circuit Simple circuit model*: ...
... The human cardiovascular system consists of two circuits: pulmonary circulation which carries blood though the lungs, and systemic circulation which carries blood to the organs The organs of the body are connected in parallel in the systemic circuit Simple circuit model*: ...
4200-DR Series LaserSource User's Manual
... therefore inside the rack housing, be sure that the internal rack ambient temperature (which will typically be several degrees higher than room ambient) does not exceed the unit’s operating temperature. If only racking one instrument, you will also need a bay blank (p/n 1400-BL) to cover the second ...
... therefore inside the rack housing, be sure that the internal rack ambient temperature (which will typically be several degrees higher than room ambient) does not exceed the unit’s operating temperature. If only racking one instrument, you will also need a bay blank (p/n 1400-BL) to cover the second ...
AD7171 数据手册DataSheet下载
... access the data register of the ADC. Eight status bits accompany each data read. See Figure 13 for further details. The DOUT/RDY falling edge can be used as an interrupt to a processor, indicating that new data is available. If the data is not read after the conversion, the pin goes high before the ...
... access the data register of the ADC. Eight status bits accompany each data read. See Figure 13 for further details. The DOUT/RDY falling edge can be used as an interrupt to a processor, indicating that new data is available. If the data is not read after the conversion, the pin goes high before the ...
NMI M 6-1 Electricity Meters. Part 1: Metrological and Technical
... energy corresponding to the maximum current without returning to the same index has been increased from 1 500 to 4 000 h. Clause 7.5 and Annex A.1.3 — a new clause has been added regarding optical ports. Annex A.2.9 — the frequency range for the test for the effect of radiated electromagnetic fields ...
... energy corresponding to the maximum current without returning to the same index has been increased from 1 500 to 4 000 h. Clause 7.5 and Annex A.1.3 — a new clause has been added regarding optical ports. Annex A.2.9 — the frequency range for the test for the effect of radiated electromagnetic fields ...
introduction
... The IC 723 general purpose regulator can be adjusted over a wide range of both positive and negative regulated voltage. This IC is a low current device, but can be boosted to provide 5 amps or more current by connecting external components. ...
... The IC 723 general purpose regulator can be adjusted over a wide range of both positive and negative regulated voltage. This IC is a low current device, but can be boosted to provide 5 amps or more current by connecting external components. ...
Multimeter
A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.