BD6369GUL
... 7) Setting of PWM signal input VLIM and CLIM terminals (all series) It is also possible to compose filters outside the IC, change an input voltage for output voltage and output current setting terminals such as VLIM and CLIM terminals by the DUTY control using an PWM signal, etc., and use them as se ...
... 7) Setting of PWM signal input VLIM and CLIM terminals (all series) It is also possible to compose filters outside the IC, change an input voltage for output voltage and output current setting terminals such as VLIM and CLIM terminals by the DUTY control using an PWM signal, etc., and use them as se ...
EMC: electromagnetic compatibility
... capacitance of 100 pF is sufficient to generate currents of several hundred milliamperes. This disturbance current will flow through the zero reference conductor and can modify signals (data or commands), be superimposed on sensitive measurements and disturb other equipment by injecting the disturba ...
... capacitance of 100 pF is sufficient to generate currents of several hundred milliamperes. This disturbance current will flow through the zero reference conductor and can modify signals (data or commands), be superimposed on sensitive measurements and disturb other equipment by injecting the disturba ...
PowerPoint 簡報
... e) typical peripheral(bar code scanner); f) handheld device(bar code scanner); The results of an evaluation of EUTs having one of each type of module or ITE can be applied to configurations having more than one of each of those modules or ITE.This is permissible because it has been found that distur ...
... e) typical peripheral(bar code scanner); f) handheld device(bar code scanner); The results of an evaluation of EUTs having one of each type of module or ITE can be applied to configurations having more than one of each of those modules or ITE.This is permissible because it has been found that distur ...
DAC161S997 16-bit SPI Programmable DAC for 4
... 8.3.1.2 SPI Timeout Error (Channel Error) The DAC161S997 expects to receive periodic SPI write commands to ensure that the SPI connection is functioning normally. If no SPI write command occurs within the time indicated by the SPI_TIMEOUT field in the ERROR_CONFIG register, the device reports a SPI ...
... 8.3.1.2 SPI Timeout Error (Channel Error) The DAC161S997 expects to receive periodic SPI write commands to ensure that the SPI connection is functioning normally. If no SPI write command occurs within the time indicated by the SPI_TIMEOUT field in the ERROR_CONFIG register, the device reports a SPI ...
TD-1 Manual - Millennia Media
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
Autotransformer 120/240V - 32A and 120/240 - 100A
... The solution is an Autotransformer. By leaving the neutral of the split phase supply unused, and connecting an Autotransformer to create a new neutral, as shown in figure 1, any load unbalance is ‘absorbed’ by the Autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 2 ...
... The solution is an Autotransformer. By leaving the neutral of the split phase supply unused, and connecting an Autotransformer to create a new neutral, as shown in figure 1, any load unbalance is ‘absorbed’ by the Autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 2 ...
BD9C301FJ
... digital and analog blocks to prevent noise in the ground and supply lines of the digital block from affecting the analog block. Furthermore, connect a capacitor to ground at all power supply pins. Consider the effect of temperature and aging on the capacitance value when using electrolytic capacitor ...
... digital and analog blocks to prevent noise in the ground and supply lines of the digital block from affecting the analog block. Furthermore, connect a capacitor to ground at all power supply pins. Consider the effect of temperature and aging on the capacitance value when using electrolytic capacitor ...
GI Part 40. Safety-Related Work Practices Compared With – Electrical
... electric equipment or circuits which have been deenergized, the circuits energizing the parts shall be locked out or tagged or both in accordance with the requirements of this paragraph. The requirements shall be followed in the order in which they are presented (i.e., paragraph (b)(2)(i) first, the ...
... electric equipment or circuits which have been deenergized, the circuits energizing the parts shall be locked out or tagged or both in accordance with the requirements of this paragraph. The requirements shall be followed in the order in which they are presented (i.e., paragraph (b)(2)(i) first, the ...
MBE 901
... Removed and laid out as a spare outside the enclosure Removed from the cable route. Cables shall be laid out as spares inside enclosures in accordance with MBE 401. Cables shall be laid out as spares outside enclosures in accordance with instructions from the responsible designer. Cables or cond ...
... Removed and laid out as a spare outside the enclosure Removed from the cable route. Cables shall be laid out as spares inside enclosures in accordance with MBE 401. Cables shall be laid out as spares outside enclosures in accordance with instructions from the responsible designer. Cables or cond ...
HMC547LP3
... the switch offers high isolation and low insertion loss. The switch features >50 dB isolation up to 5 GHz and >45 dB isolation up to 15 GHz. The ...
... the switch offers high isolation and low insertion loss. The switch features >50 dB isolation up to 5 GHz and >45 dB isolation up to 15 GHz. The ...
Evaluation Board User Guide UG-339
... 100 MΩ impedance of these probes sources/sinks current from the input depending on their bias. ...
... 100 MΩ impedance of these probes sources/sinks current from the input depending on their bias. ...
Precision Digital PD686 3-1/2 Digit NEMA 4X Loop
... Note: To maintain hazardous area protection, the input signal must always be connected to the Input Signal PCB, and not directly to the Display PCB. Warning: Electrostatic hazard. Clean only with a moist cloth. Protect enclosure from exposure to chemical solvents and excessive ultraviolet (UV) light ...
... Note: To maintain hazardous area protection, the input signal must always be connected to the Input Signal PCB, and not directly to the Display PCB. Warning: Electrostatic hazard. Clean only with a moist cloth. Protect enclosure from exposure to chemical solvents and excessive ultraviolet (UV) light ...
LTC6360 - Very Low Noise Single-Ended SAR ADC Driver with True Zero Output
... The LTC6360 is a low noise amplifier suitable for driving single-ended high performance successive approximation register (SAR) ADCs. The LTC6360 uses a single amplifier with negative charge pump topology as shown in the Block Diagram. The output can swing from –0.48V to 4.91V. The amplifier is desi ...
... The LTC6360 is a low noise amplifier suitable for driving single-ended high performance successive approximation register (SAR) ADCs. The LTC6360 uses a single amplifier with negative charge pump topology as shown in the Block Diagram. The output can swing from –0.48V to 4.91V. The amplifier is desi ...
I56-3889-002R - Silent Knight
... power from the fire/security panel monitoring the alarm system. If power is cut off for any reason, the sounder/strobe will not provide the desired audio or visual warning. The sounder may not be heard. The loudness of the sounder meets (or exceeds) current Underwriters Laboratories’ standards. Stud ...
... power from the fire/security panel monitoring the alarm system. If power is cut off for any reason, the sounder/strobe will not provide the desired audio or visual warning. The sounder may not be heard. The loudness of the sounder meets (or exceeds) current Underwriters Laboratories’ standards. Stud ...
section 16340-1 - Schneider Electric
... * Maximum symmetrical kA interrupting ratings are based on Table 1 of C37.06-1997. MVA ratings are nominal reference values for comparison only. 2. An interlocking system shall be provided to prevent racking a closed circuit breaker to or from any position. An additional interlock shall automaticall ...
... * Maximum symmetrical kA interrupting ratings are based on Table 1 of C37.06-1997. MVA ratings are nominal reference values for comparison only. 2. An interlocking system shall be provided to prevent racking a closed circuit breaker to or from any position. An additional interlock shall automaticall ...
Electrical safety at places of entertainment Guidance Note GS50 (Third edition)
... system should be designed so that the load is shared between them. 33 Unless the generator is supplying only double insulated equipment within a few metres of itself, there is a risk that a fault in the equipment, the cables or the generator could cause the equipment casing to become live without b ...
... system should be designed so that the load is shared between them. 33 Unless the generator is supplying only double insulated equipment within a few metres of itself, there is a risk that a fault in the equipment, the cables or the generator could cause the equipment casing to become live without b ...
EARTHING: Your questions answered
... The probes and gripping clips of some connecting leads are fitted with fuses. The fuses protect the user and the equipment from high currents that may be unexpectedly encountered. Suitably rated highbreaking capacity (HBC) or high-rupturing capacity (HRC) fuses should be used, usually not exceeding ...
... The probes and gripping clips of some connecting leads are fitted with fuses. The fuses protect the user and the equipment from high currents that may be unexpectedly encountered. Suitably rated highbreaking capacity (HBC) or high-rupturing capacity (HRC) fuses should be used, usually not exceeding ...
LT6604-2.5
... Note 8: Input pins (+IN, –IN, VOCM and VMID) are protected by steering diodes to either supply. If the inputs should exceed either supply voltage, the input current should be limited to less than 10mA. In addition, the inputs +IN, –IN are protected by a pair of back-to-back diodes. If the differenti ...
... Note 8: Input pins (+IN, –IN, VOCM and VMID) are protected by steering diodes to either supply. If the inputs should exceed either supply voltage, the input current should be limited to less than 10mA. In addition, the inputs +IN, –IN are protected by a pair of back-to-back diodes. If the differenti ...