• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electrical Noise . . . Sources, Symptoms and Solutions
Electrical Noise . . . Sources, Symptoms and Solutions

Signal Buffer Board HOWTO Rev 1
Signal Buffer Board HOWTO Rev 1

... used to change the impedance of input potentiometers, as higher impedance (above 5K) can cause channel-to-channel bleedover at an A-to-D converter. The circuit can also be used to amplify pot sweep, if it is too small. Note that amplification also amplifies noise, which is undesirable in the system, ...
3A1981
3A1981

... 5. Please install the protector module inaccordance with the applicable requirements of the National Electrical Code®, Article 800 or other applicable local codes. 6. Screw terminal ratings with the applicable wire gauge sizes shall be noted. 7. The maximum circuit current for UL 497 B application i ...
Abstract - theelectromech.in
Abstract - theelectromech.in

... galvanic isolation between the grid and the PV panels. In order to increase the efficiency, to reduce the size and cost, the effective solution is to remove the isolation transformer. It leads to appearance of common mode (CM) ground leakage current due to parasitic capacitance between the PV panels ...
Electrical Grounds
Electrical Grounds

... and shape Typically, the target resistance is dictated by company standards. Less than 5 ohms is a common value used in the telecommunication industry. Soil resistivity is a given based on site conditions and "f" is a function based on the shape, size, type and layout of the electrode. A good design ...
Floating Signal Inputs
Floating Signal Inputs

MARIA VAN BOMMEL PRESS RELEASE
MARIA VAN BOMMEL PRESS RELEASE

... Stray voltage is man-made electromagnetic energy. The laws of electric engineering require that electrons flowing from a substation transformer must return to that transformer in order to complete the circuit. This is done by the use of neutral wire that exists on the distribution and transmission s ...
Medical Instrumentation Application Lecture #1
Medical Instrumentation Application Lecture #1

High Voltage Direct Current Test Procedure
High Voltage Direct Current Test Procedure

... 3. Conductors shall be tested in the following sequence: a) On the neutral conductor before it is grounded, and b) On the power conductors with the neutral and other conductors permanently or temporarily grounded. 4. With voltage at 0, attach high-voltage lead to the circuit conductor to be tested a ...
What hap- pens inside a micro- phone once a sensor detects a
What hap- pens inside a micro- phone once a sensor detects a

... Microphones — and speakers — are transducers that convert mechanical energy (sound) to electrical energy and vice versa, as shown in the diagram above. This is traditionally done with a coil of wire wrapped around a magnet, as shown in the diagram below. If the coil is moved, a voltage is produced. ...
DET62D Three-Terminal Ground Resistance Tester
DET62D Three-Terminal Ground Resistance Tester

Module 20 – Electrical Safety C9
Module 20 – Electrical Safety C9

3A1980
3A1980

... 3. The base shall be secured to a compatible DIN-Rail ground bar using the methods described in this instruction. 4. Proper grounding continuity shall be determined. 5. Please install the protector module inaccordance with the applicable requirements of the National Electrical Code®, Article 800 or ...
Grounding and Shielding Existing Equipment
Grounding and Shielding Existing Equipment

Grounding and Shielding
Grounding and Shielding

Download PGN-3000 Datasheet
Download PGN-3000 Datasheet

... The PGN Pulsing High-Resistance-Grounding Systems are used to ground power systems by inserting a resistor between system neutral and ground to lower the ground-fault current to a predetermined value. Properly sized Resistance Grounding Systems solve two problems of ungrounded systems—transient over ...
Kollmorgen 8Ch Digital Output Datasheet en
Kollmorgen 8Ch Digital Output Datasheet en

Our Friend the Direct Box
Our Friend the Direct Box

... microphone equivalent of 0.0075VRMS, or -40dBu. If a microphone preamplifier receives an input voltage exceeding its operating level, it will become overdriven and distort. Furthermore, the preamp can actually be damaged. The grounds of the instrument must be isolated from the grounds of the system. ...
Solutions #3
Solutions #3

... v1 HtL = 0.1 cosH20 p tL + 20 sinH120 p tL and v2 HtL = -0.1 cosH20 p tL + 20 sinH120 p tL Find expressions for the common-mode signal and the differential signal. ü Solution: The common-mode signal is given by ...
Electronics & Signals
Electronics & Signals

AN-42036 PCB Grounding System and FAN2001/FAN2011 High Performance DC-DC Converters Introduction
AN-42036 PCB Grounding System and FAN2001/FAN2011 High Performance DC-DC Converters Introduction

... offsets and noise into the signal return paths. In star grounding, a common point is chosen to which to connect all ground lines. A physical point is chosen on the circuit board to serve as the star ground point and all grounds radiate from that point to the separate parts of the system. Any one of ...
UC BERKELEY MEDIUM VOLTAGE GROUNDING SYSTEM
UC BERKELEY MEDIUM VOLTAGE GROUNDING SYSTEM

Understanding Ground Loops
Understanding Ground Loops

... at the building power entrance. The ground is a copper rod driven a minimum of 8 feet into the ground. The NEC requires that the structural steel frame, water pipes and other major metal objects be connected to the building entrance ground. If a wire’s insulation breaks down or a wire inadvertently ...
Electricity - 7SMSscience
Electricity - 7SMSscience

... to pass through (ex. metal) Insulator – substance that does not readily conduct electricity; does not allow electricity to pass through (ex. plastic) ...
Electricity
Electricity

< 1 ... 318 319 320 321 322 323 324 325 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.