DATASHEET: Furman AR-1220
... Instead, it uses a use a design based on an eight-tap toroidal autoformer. The toroidal design assures minimal leakage of stray magnetic fields. The AR-1220 circuitry monitors the incoming line voltage with each cycle, comparing it to an extremely precise voltage reference, accurate to ±0.15%. If a ...
... Instead, it uses a use a design based on an eight-tap toroidal autoformer. The toroidal design assures minimal leakage of stray magnetic fields. The AR-1220 circuitry monitors the incoming line voltage with each cycle, comparing it to an extremely precise voltage reference, accurate to ±0.15%. If a ...
Low Capacitance Diode Array for ESD Protection in Four Data Lines
... ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any partic ...
... ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any partic ...
AN-793 APPLICATION NOTE
... almost all cases the distinction between a component and a system is obvious. However, the differences between component and system tests may not be so obvious. Further, component specifications may not directly indicate how a device will perform in system - level testing. ESD testing is a good exam ...
... almost all cases the distinction between a component and a system is obvious. However, the differences between component and system tests may not be so obvious. Further, component specifications may not directly indicate how a device will perform in system - level testing. ESD testing is a good exam ...
Bravo AV`s Structured Wiring Approach
... The modular jack/plug commonly used at the two ends of computer network. Run or Drop A length of cable or wire that is run from a room to the head-end location. Splitter A signal divider that splits an incoming signal into multiple output signals, as would be required to supply multiple TV sets from ...
... The modular jack/plug commonly used at the two ends of computer network. Run or Drop A length of cable or wire that is run from a room to the head-end location. Splitter A signal divider that splits an incoming signal into multiple output signals, as would be required to supply multiple TV sets from ...
Pulsating Signal Injection-Based Axis Switching Sensorless Control
... minimize position detection error and velocity estimation ripple resulting from the zero-currentclamping (ZCC) effect for surface-mounted permanentmagnet motors. ...
... minimize position detection error and velocity estimation ripple resulting from the zero-currentclamping (ZCC) effect for surface-mounted permanentmagnet motors. ...
Equation 1
... 6. Measure the magnitude of the voltages across the inductor, capacitor and the resistor for the frequencies chosen in Table 1. For all of these measurements adjust the Volts/Div until there is no DC offset to the waveforms and until you can clearly see each sinusoidal waveform (if the sinusoidal wa ...
... 6. Measure the magnitude of the voltages across the inductor, capacitor and the resistor for the frequencies chosen in Table 1. For all of these measurements adjust the Volts/Div until there is no DC offset to the waveforms and until you can clearly see each sinusoidal waveform (if the sinusoidal wa ...
Isolated 4 to 20 mA Transmitters For Demanding Applications
... applied across the input or output leads for 1 minute for all models with voltage or thermocouple inputs. Reverse polarity of 400 Vp may be applied across the output leads indefinitely. These exceptionally high NMV overvoltage ratings provide further protection against possible electrical faults and ...
... applied across the input or output leads for 1 minute for all models with voltage or thermocouple inputs. Reverse polarity of 400 Vp may be applied across the output leads indefinitely. These exceptionally high NMV overvoltage ratings provide further protection against possible electrical faults and ...
START-DET PMT-Base-H..
... covered with two layers of heat shrink tubing. Areas which could not be covered in this manner were sealed with RTV sealant. The HV was connected to the PC board via 5 KV rated silicone wires. One wire was further covered with heat shrink tubing. The area where the wires were soldered to the PC boar ...
... covered with two layers of heat shrink tubing. Areas which could not be covered in this manner were sealed with RTV sealant. The HV was connected to the PC board via 5 KV rated silicone wires. One wire was further covered with heat shrink tubing. The area where the wires were soldered to the PC boar ...
AT6200/AT6400
... command language, a powerful command language that is flexible enough to implement complex motion control applications and simple enough to not overwhelm the novice programmer. The AT6200 and AT6400 come standard with Motion Architect, ...
... command language, a powerful command language that is flexible enough to implement complex motion control applications and simple enough to not overwhelm the novice programmer. The AT6200 and AT6400 come standard with Motion Architect, ...
ONEAC Powervar ONePlus Series
... Full output isolation: ONEAC’s proprietary transformer design incorporates power conditioning magnetics and voltage regulation magnetics in a single compact unit. Provides superior protection against lightning and other high energy surges. Virtual Kelvin Ground®: Eliminates the full spectrum of cond ...
... Full output isolation: ONEAC’s proprietary transformer design incorporates power conditioning magnetics and voltage regulation magnetics in a single compact unit. Provides superior protection against lightning and other high energy surges. Virtual Kelvin Ground®: Eliminates the full spectrum of cond ...
ELECTRONIC RATIO BOX
... square wave output set to a peak to peak voltage matching the supply line. Some 24volt systems are looking for signals at this level. Maximum output frequency is ~ 500 Hz regardless of ratio. Minimum output frequency is 5 Hz regardless of ratio. For setting ratios outside these parameters contact th ...
... square wave output set to a peak to peak voltage matching the supply line. Some 24volt systems are looking for signals at this level. Maximum output frequency is ~ 500 Hz regardless of ratio. Minimum output frequency is 5 Hz regardless of ratio. For setting ratios outside these parameters contact th ...
Earth Leakage Problem of Superconductor Magnet System at TLS
... the coil. It has been observed in the pilot test at TLS that there is about 300mA earth leakage current flowing through the earth leakage protection circuit, which presented an interlock and halted the whole system down. The existence of earth leakage current may undermine the overall system stabili ...
... the coil. It has been observed in the pilot test at TLS that there is about 300mA earth leakage current flowing through the earth leakage protection circuit, which presented an interlock and halted the whole system down. The existence of earth leakage current may undermine the overall system stabili ...
voltage sources in parallel
... SERIES-PARALLEL NETWORKS series-parallel networks are networks that contain both series and parallel circuit configurations. Examine each region of the network independently before tying them together in series-parallel combinations. This will usually simplify the network and possibly reveal a di ...
... SERIES-PARALLEL NETWORKS series-parallel networks are networks that contain both series and parallel circuit configurations. Examine each region of the network independently before tying them together in series-parallel combinations. This will usually simplify the network and possibly reveal a di ...