CN-0151 利用DAC、运算放大器和MOSFET 晶体管,构建多功能高精度可编程电流源
... by the breakdown voltage of the MOSFET transistor. The ADR425 is an ideal 5 V low power precision reference for this circuit, but its output must be inverted with an additional op amp to generate the −5 V reference. ...
... by the breakdown voltage of the MOSFET transistor. The ADR425 is an ideal 5 V low power precision reference for this circuit, but its output must be inverted with an additional op amp to generate the −5 V reference. ...
Avoid generating capacity losses in aging hydropower plants
... High-impedance grounding units provide a cost-effective solution to a potentially expensive problem while dramatically enhancing equipment reliability and personnel safety by increasing protection against harmful and damaging ground fault events. Customized units can be engineered to help manage the ...
... High-impedance grounding units provide a cost-effective solution to a potentially expensive problem while dramatically enhancing equipment reliability and personnel safety by increasing protection against harmful and damaging ground fault events. Customized units can be engineered to help manage the ...
TD1016: An overview of Lightning Protection for Ham
... • Install additional bare radial lines with ground rods which will effectively parallel the inductance and reduce the overall system inductance. In some locations it may be necessary to utilize all three of these techniques for the best results. Let's examine each one. 1) Conductor Surface Area: The ...
... • Install additional bare radial lines with ground rods which will effectively parallel the inductance and reduce the overall system inductance. In some locations it may be necessary to utilize all three of these techniques for the best results. Let's examine each one. 1) Conductor Surface Area: The ...
Line Voltage Wall Switch Occupancy Sensors and Neutral Conductors
... required to perform passive infrared (PIR) or ultrasonic sensing functions to detect motion. In dual technology sensors both sets of circuitry are present. Sensors also contain microprocessor based control circuitry to govern operation of the sensor as well as relays and their associated coil driver ...
... required to perform passive infrared (PIR) or ultrasonic sensing functions to detect motion. In dual technology sensors both sets of circuitry are present. Sensors also contain microprocessor based control circuitry to govern operation of the sensor as well as relays and their associated coil driver ...
Electrical Class Handout (Primary)
... that are fed by circuit to which cords or cables are connected must have overcurrent protection that protects the cord or cable as well as equipment in the tent or concession stand. There must be overcurrent protection in the tent or concession. Section 525-30 entitled “Type and Location,” states th ...
... that are fed by circuit to which cords or cables are connected must have overcurrent protection that protects the cord or cable as well as equipment in the tent or concession stand. There must be overcurrent protection in the tent or concession. Section 525-30 entitled “Type and Location,” states th ...
High speed digital design
... In general, a trace grounded at both ends separating two signal traces will half the coupling In homogeneous digital system, solid ground plane can reduce the crosstalk to 1-3% which is good enough. But need to be more careful with analogue system which mixes high power (output) signals with low ...
... In general, a trace grounded at both ends separating two signal traces will half the coupling In homogeneous digital system, solid ground plane can reduce the crosstalk to 1-3% which is good enough. But need to be more careful with analogue system which mixes high power (output) signals with low ...
DPR-901ii User`s Manual
... A vertical rack space of 1U (1.75", 44.5mm) is required. Figure 2.1 details the relevant dimensions and fixing centres. If the unit is part of a transportable system, you must support the unit at it’s rear by additional bracing or shelving . Failure to do so will impair reliability and invalidate th ...
... A vertical rack space of 1U (1.75", 44.5mm) is required. Figure 2.1 details the relevant dimensions and fixing centres. If the unit is part of a transportable system, you must support the unit at it’s rear by additional bracing or shelving . Failure to do so will impair reliability and invalidate th ...
wiring diagram
... - WIRE THE RELAY AND CONNECT ACCORDING TO TYPICAL WIRING DIAGRAMS. ONCE MOUNTING AND WIRING HAVE BEEN COMPLETED, RETURN POWER TO THE HEATING SYSTEM AND TEST THE INSTALLATION. - INCREASE THE THERMOSTAT TEMPERATURE TO ACTIVATE THE RELAY. ALLOW SYSTEM OPERATION LONG ENOUGH TO CONFIRM CORRECT INSTALLATI ...
... - WIRE THE RELAY AND CONNECT ACCORDING TO TYPICAL WIRING DIAGRAMS. ONCE MOUNTING AND WIRING HAVE BEEN COMPLETED, RETURN POWER TO THE HEATING SYSTEM AND TEST THE INSTALLATION. - INCREASE THE THERMOSTAT TEMPERATURE TO ACTIVATE THE RELAY. ALLOW SYSTEM OPERATION LONG ENOUGH TO CONFIRM CORRECT INSTALLATI ...
Evaluates: MAX3802 MAX3802 Evaluation Kit General Description Features
... 3) Adjust R13, the R MOD1 potentiometer, for 20kΩ resistance by turning the potentiometer clockwise until a faint click is heard. 4) Potentiometer R13 (R MOD 1) can be adjusted between 10kΩ and 20kΩ to change the cable driver output amplitude. Note: Measuring the resistance on the potentiometer is d ...
... 3) Adjust R13, the R MOD1 potentiometer, for 20kΩ resistance by turning the potentiometer clockwise until a faint click is heard. 4) Potentiometer R13 (R MOD 1) can be adjusted between 10kΩ and 20kΩ to change the cable driver output amplitude. Note: Measuring the resistance on the potentiometer is d ...
Technical Means of Automation
... allows continuous measurement in real time voltage and current probes frequency of sampling (e.g. 100Mhz) number of channels (2CH, 4CH) logic signal analyzer (decoding) built-in features ...
... allows continuous measurement in real time voltage and current probes frequency of sampling (e.g. 100Mhz) number of channels (2CH, 4CH) logic signal analyzer (decoding) built-in features ...
Regulators for Ford 6G Alternators
... a sudden load is applied to the charging system, the computer senses the load and effectively lowers the regulation set point voltage for a few seconds and then adjusts the signal to satisfy the demand of the vehicle electrical system. It should be noted that the PCM also monitors other ...
... a sudden load is applied to the charging system, the computer senses the load and effectively lowers the regulation set point voltage for a few seconds and then adjusts the signal to satisfy the demand of the vehicle electrical system. It should be noted that the PCM also monitors other ...
DE-ACCM6G - Dimension Engineering
... It is important to note that the X and Y outputs remain unclamped, i.e. 0g still corresponds to Vcc/2 . So if one accidentally powers a DE-ACCM5G with 14V, the outputs would read 7v or more, which might be enough to damage an external device connected at the time. Reverse voltage Even the best engin ...
... It is important to note that the X and Y outputs remain unclamped, i.e. 0g still corresponds to Vcc/2 . So if one accidentally powers a DE-ACCM5G with 14V, the outputs would read 7v or more, which might be enough to damage an external device connected at the time. Reverse voltage Even the best engin ...
I 2
... Ammeters and Voltmeters •An ammeter is a device that measures the current (amps) anywhere in a circuit A •To use it, you must route the current through it •A perfect ammeter should have zero resistance •A voltmeter is a device that measures the potential difference (volts) between any two points in ...
... Ammeters and Voltmeters •An ammeter is a device that measures the current (amps) anywhere in a circuit A •To use it, you must route the current through it •A perfect ammeter should have zero resistance •A voltmeter is a device that measures the potential difference (volts) between any two points in ...
The Wahleach Hydroelectric Development
... 23 feet square and 16 feet high between two floors of the building. The overall height from the bottom of the turbine to the top of the generator is slightly more than 49 feet. The stator windings are wye-connected, with the neutral completely insulated from ground. Ground detection is provided by a ...
... 23 feet square and 16 feet high between two floors of the building. The overall height from the bottom of the turbine to the top of the generator is slightly more than 49 feet. The stator windings are wye-connected, with the neutral completely insulated from ground. Ground detection is provided by a ...
IEEE Memphis Protection-Basics
... – Security: Don’t trip when you shouldn’t – Dependability: Trip when you should ...
... – Security: Don’t trip when you shouldn’t – Dependability: Trip when you should ...
Experiment
... Partially adopted and edited from “Signal Interference and Shielding.” Courtesy of University of Pennsylvania ESE department ...
... Partially adopted and edited from “Signal Interference and Shielding.” Courtesy of University of Pennsylvania ESE department ...
High Voltage Power Supply Using the TPS61040
... TPS61040. An unregulated output voltage of 1/2 Vout is available from node 2 in this configuration. If desired, the feedback can be recalculated for a 25 V output and connected to node 2. This provides a regulated 25–V output and an unregulated 50–V output. D1, D2, and D3 must be rated for at least ...
... TPS61040. An unregulated output voltage of 1/2 Vout is available from node 2 in this configuration. If desired, the feedback can be recalculated for a 25 V output and connected to node 2. This provides a regulated 25–V output and an unregulated 50–V output. D1, D2, and D3 must be rated for at least ...
A state-of-the-art 2.3GHz Pre-amplifier
... Agilent call the device an Enhancement-mode Pseudomorphic High Electron Mobility Transistor, or EPHEMT. HEMTs have been around for some time now, and will be familiar to anybody who has built a microwave low noise amplifier (LNA). 'Pseudomorphic' is a development of the basic HEMT, and refers to the ...
... Agilent call the device an Enhancement-mode Pseudomorphic High Electron Mobility Transistor, or EPHEMT. HEMTs have been around for some time now, and will be familiar to anybody who has built a microwave low noise amplifier (LNA). 'Pseudomorphic' is a development of the basic HEMT, and refers to the ...