2SB1707
... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger ...
... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger ...
AT6731
... Information provided by IAT is believed to be accurate and reliable. However, we cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in an IAT product; nor for any infringement of patents or other rights of third parties that may result from its use. We reser ...
... Information provided by IAT is believed to be accurate and reliable. However, we cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in an IAT product; nor for any infringement of patents or other rights of third parties that may result from its use. We reser ...
Series and parallel circuits
... The same amount of current flows though each component equally. Both lamps will light to the same brightness. The energy given by the cell as potential difference, measured in Volts, (v) is used by the two lamps, which turn that energy into the form of heat and light. Each lamp has a resistance meas ...
... The same amount of current flows though each component equally. Both lamps will light to the same brightness. The energy given by the cell as potential difference, measured in Volts, (v) is used by the two lamps, which turn that energy into the form of heat and light. Each lamp has a resistance meas ...
3A1636
... designed to be installed without additional fuses per UL 1449 3rd Edition. It is suitable for use on a circuit with maximum SCCR and Nominal Voltage according to Technical Data. This device features an internal protection system that will disconnect the surge protective module at the end of its usef ...
... designed to be installed without additional fuses per UL 1449 3rd Edition. It is suitable for use on a circuit with maximum SCCR and Nominal Voltage according to Technical Data. This device features an internal protection system that will disconnect the surge protective module at the end of its usef ...
“conducted immunity” mean?
... Interconnecting cables 30 to 50mm above GRP. CDNs 0.1 to 0.3m from the projection of the EUT onto the reference plane. Rules for selecting the injection method. (see 7.1.1) CDNs are preferred. Only two CDNs required. One has the signal injected, the other is terminated, providing a 150 ohm impedance ...
... Interconnecting cables 30 to 50mm above GRP. CDNs 0.1 to 0.3m from the projection of the EUT onto the reference plane. Rules for selecting the injection method. (see 7.1.1) CDNs are preferred. Only two CDNs required. One has the signal injected, the other is terminated, providing a 150 ohm impedance ...
Using Standard Transformers in Multiple Applications
... What to Consider A transformer winding might be constructed of multiple wires intended to be connected in parallel. The user might instead consider connecting those wires in series to increase the resulting inductance or turns ratio. Careful consideration of all the resulting variables should be mad ...
... What to Consider A transformer winding might be constructed of multiple wires intended to be connected in parallel. The user might instead consider connecting those wires in series to increase the resulting inductance or turns ratio. Careful consideration of all the resulting variables should be mad ...
NCEA Level 3 Physics (91526) 2013 Assessment Schedule
... When the circuit is in resonance, the current is greatest because the reactance is zero and so the impedance is smallest. When the current is greatest the sound from the speaker is loudest. The current decreases rapidly either side of resonance because the reactance increases either side of resonanc ...
... When the circuit is in resonance, the current is greatest because the reactance is zero and so the impedance is smallest. When the current is greatest the sound from the speaker is loudest. The current decreases rapidly either side of resonance because the reactance increases either side of resonanc ...
B++--The Design of A Low-Power Low-Noise Phase Lock
... reference signal remains constant or is zero However, if in the process due to some discrepancy a phase error builds up, a control mechanism gets triggered, which acts on the oscillator to counter-balance the so resulted phase error in such a manner that it is reduced to minimum until it is matched. ...
... reference signal remains constant or is zero However, if in the process due to some discrepancy a phase error builds up, a control mechanism gets triggered, which acts on the oscillator to counter-balance the so resulted phase error in such a manner that it is reduced to minimum until it is matched. ...
ANT-868-JJB-HT-x Data Sheet
... What is VSWR? The Voltage Standing Wave Ratio (VSWR) is a measurement of how well an antenna is matched to a source impedance, typically 50-ohms. It is calculated by measuring the voltage wave that is headed toward the load versus the voltage wave that is reflected back from the load. A perfect matc ...
... What is VSWR? The Voltage Standing Wave Ratio (VSWR) is a measurement of how well an antenna is matched to a source impedance, typically 50-ohms. It is calculated by measuring the voltage wave that is headed toward the load versus the voltage wave that is reflected back from the load. A perfect matc ...
DCM2031, 2033, 2039 Digital Clampmeters
... data hold button for freezing the reading. The highest current unit available in the series is the DCM2039. This instrument has a specified accuracy for measurements to 1000 A but has an over-range capability of up to 2000 A. As the clamp incorporates Hall Effect technology it can measure d.c. curre ...
... data hold button for freezing the reading. The highest current unit available in the series is the DCM2039. This instrument has a specified accuracy for measurements to 1000 A but has an over-range capability of up to 2000 A. As the clamp incorporates Hall Effect technology it can measure d.c. curre ...
Testing box type E-RI-TEST
... The E-RI-TEST must be interposed between the Machine Control Unit through the main connector and the proportional valve through the annexed connector and cable. 6.1 Power supply The power supply must be provided through pin A and B of the main connector of the E-RI-TEST. A safety fuse is present ...
... The E-RI-TEST must be interposed between the Machine Control Unit through the main connector and the proportional valve through the annexed connector and cable. 6.1 Power supply The power supply must be provided through pin A and B of the main connector of the E-RI-TEST. A safety fuse is present ...
NC400 04xx Datasheet
... Design for a few Watts, making the Pidle predominant and therefore: Ploss ≈ Pidle Required heatsinking is = 45K / 4,5W = 10 K/W. As it happens, the NC400 without additional cooling has a thermal resistance of around 6K/W. This indicates that free-air cooling is an option in most cases, at least prov ...
... Design for a few Watts, making the Pidle predominant and therefore: Ploss ≈ Pidle Required heatsinking is = 45K / 4,5W = 10 K/W. As it happens, the NC400 without additional cooling has a thermal resistance of around 6K/W. This indicates that free-air cooling is an option in most cases, at least prov ...