• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
HMC855LC5
HMC855LC5

UNIT 1 Microelectronics and Electronic Circuits
UNIT 1 Microelectronics and Electronic Circuits

... concentration of electrons in the channel provides a path by which the electrons can move easily from the source to the drain. When that happens, the MOSFET is ‘on’ (or ‘closed’) and current can flow from the source to the drain freely.” “In summary, a MOSFET in a microchip is turned on by applying ...
mGARD-100 - I-Gard
mGARD-100 - I-Gard

12A02MH 数据资料DataSheet下载
12A02MH 数据资料DataSheet下载

... aerospace instrument, nuclear control device, burning appliances, transportation machine, traffic signal system, safety equipment etc.) that shall require extremely high level of reliability and can directly threaten human lives in case of failure or malfunction of the product or may cause harm to h ...
HT3213861389
HT3213861389

pptx
pptx

Evaluates:  MAX4080/MAX4081 MAX4080 Evaluation Kit General Description Features
Evaluates: MAX4080/MAX4081 MAX4080 Evaluation Kit General Description Features

... Follow the steps below to verify board operation. Caution: Do not turn on the power supply or the electronic load until all connections are completed. 1) MAX4081 only: Verify that a shunt is installed across pins 1-2 of jumper JU1. 2) MAX4081 only: Verify that a shunt is installed across pins 1-2 of ...
unit IV_AC Measurements
unit IV_AC Measurements

The Oscilloscope
The Oscilloscope

... A constant deflection voltage will move the spot on the screen a fixed horizontal distance. A varying (AC) voltage, on the other hand, will deflect the beam horizontally back and forth since the polarity is continually changing. If the frequency of the AC voltage signal is high enough, the spot will ...
PDF
PDF

... Fig. 1. Here we also consider these improvements in the context of the circuits required to implement each scheme showing that differential signaling is the preferred method, not just for low voltage application, but also for ease of integration into existing signaling regimes. Examining Fig. 1 it i ...
样章下载
样章下载

... conventional AFC techniques necessarily entail some frequency error. To maintain the control voltage needed for lock it is generally necessary to have a nonzero output from the phase detector. Consequently, the loop operates with some phase error present. As a practical matter, however, this error t ...
Assemble Manual - DIY, audio, electronics
Assemble Manual - DIY, audio, electronics

... 5. You can use screw terminals or solder hookup wire to the PCB. Soldering is generally the best connection from an electrical / signal point of view but may be unpractical. Note that you should avoid soldering on/off the cables, especially the power and speaker cables. As these cables are usually q ...
103_unit_5
103_unit_5

... impedance to prevent the test equipment from loading the circuit under test and thereby provide inaccurate measurements. The VOM usually has a moderately high input impedance while the DMM and oscilloscope have a high input impedance of 1M or higher. This high input impedance assures the measuremen ...
1996 ISSCC 8.1 presentation slides for this paper
1996 ISSCC 8.1 presentation slides for this paper

DANGER
DANGER

... metering category III. Also, terminal wiring should have a minimum temperature rating of 80° C. Polarity marks must be followed as shown for CTs (S1=X1, S2=X2) and PTs ( ■ = X1). See Tables 1 and 4 for connector specifications and wiring symbols. ...
JohnAnalog
JohnAnalog

noise - London South Bank University
noise - London South Bank University

... Ya Bao, South Bank University ...
FlexMod™ LVD Low Voltage Disconnect
FlexMod™ LVD Low Voltage Disconnect

... off due to low battery voltage, the loads will toggle on. After 15 minutes, the LVD will resume monitoring battery voltage. If during the 15 minute period the battery voltage rises above the upper limit for ten seconds, the 15 minute delay is exited and the LVD resumes monitoring battery ...
Fortune Oregon Data Center Increases Reliability with a High
Fortune Oregon Data Center Increases Reliability with a High

... any adjacent metallic housing, conduit, or tray that provides a return path to the system grounding point. Ungrounded systems are also subject to ground faults and require careful attention to ground detection and fault protection. 2. The ground-fault protective sensitivity can be relatively indepen ...
HP 34401A Multimeter
HP 34401A Multimeter

... What if the meter will not turn on? First make sure it’s plugged in; if this is the case get a TA for assistance, the meter may have a blown fuse or need repair. The meter is on, but is not taking any readings when it’s connected to the circuit. Make sure to check that the probe inputs have been ins ...
Lecture 4
Lecture 4

... • The difference between the true and quantized value of the analog signal • Inevitable occurrence due to the finite resolution of the ADC • The magnitude of the quantization error at each sampling instant is between zero and half of one LSB. • Quantization error is modeled as noise (quantization no ...
Class B Amplifier
Class B Amplifier

...  Is the variation of vo obtained in 1.1. in accordance with the VTC obtained here? ...
Programmable Gain Amplifier
Programmable Gain Amplifier

... low impedance at the ground terminal. This is required to maintain accurate gain. Remember that the logic inputs, A0 and A1, are referenced to this ground connection, so the logic threshold voltage will be affected by the trim voltage. This is insignificant if the offset adjustment is used only to t ...
DN447 - A Complete Compact APD Bias Solution for a 10Gbits/s GPON System
DN447 - A Complete Compact APD Bias Solution for a 10Gbits/s GPON System

... dynamic range (250nA to 2.5mA). Recent communication design efforts increasingly focus on the 10Gbits/s GPON system, which demands that the transient response of the APD current monitor is less than 100ns for an input current step of two decades of magnitude. A simple compact circuit using the LT348 ...
HMC384LP4 数据资料DataSheet下载
HMC384LP4 数据资料DataSheet下载

... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
< 1 ... 199 200 201 202 203 204 205 206 207 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report