5A - SynQor
... designed to turn off when the input voltage is too low, helping to avoid an input system instability problem, which is described in more detail in the application note titled “Input System Instability” on the SynQor website. The lockout circuitry is a comparator with DC hysteresis. When the input vo ...
... designed to turn off when the input voltage is too low, helping to avoid an input system instability problem, which is described in more detail in the application note titled “Input System Instability” on the SynQor website. The lockout circuitry is a comparator with DC hysteresis. When the input vo ...
MO8009
... Output Enable (OE) Mode In the OE mode, applying logic Low to the OE pin only disables the output driver and puts it in Hi-Z mode. The core of the device continues to operate normally. Power consumption is reduced due to the inactivity of the output. When the OE pin is pulled High, the output is typ ...
... Output Enable (OE) Mode In the OE mode, applying logic Low to the OE pin only disables the output driver and puts it in Hi-Z mode. The core of the device continues to operate normally. Power consumption is reduced due to the inactivity of the output. When the OE pin is pulled High, the output is typ ...
Evolution of Very High Frequency Power Supplies
... The continuing trend of miniaturization in industrial and consumer electronics is continuously driving a demand for smaller power supplies. Weight and cost reduction demands accompany this trend. Within power supplies the major size, weight and cost drivers are typically the passive components. Incr ...
... The continuing trend of miniaturization in industrial and consumer electronics is continuously driving a demand for smaller power supplies. Weight and cost reduction demands accompany this trend. Within power supplies the major size, weight and cost drivers are typically the passive components. Incr ...
World in motion
... the amplifiers, the LV controllers offer the unique power of the Delta Tau position control systems. This concept provides great savings in both panel space and installation costs and whilst the design is optimised for operation using a 48VDC bus - a level that eliminates many regulatory concerns – ...
... the amplifiers, the LV controllers offer the unique power of the Delta Tau position control systems. This concept provides great savings in both panel space and installation costs and whilst the design is optimised for operation using a 48VDC bus - a level that eliminates many regulatory concerns – ...
> REPLACE THIS LINE WITH YOUR PAPER IDENTIFICATION NUMBER (DOUBLE-CLICK... 1 I. I
... soft-switching realization. For better performance, series-parallel LC compensation [17], and series-parallel LCC [18] compensation are proposed. By inducing an LCC compensation network on the primary side, part of the transmitting coil inductance is compensated by the series-connected capacitor. In ...
... soft-switching realization. For better performance, series-parallel LC compensation [17], and series-parallel LCC [18] compensation are proposed. By inducing an LCC compensation network on the primary side, part of the transmitting coil inductance is compensated by the series-connected capacitor. In ...
AN7 - Some Techniques for Direct Digitization of Transducer Outputs
... proves even more stringent. The type K thermocouple puts out 41.4μV/°C over the 0°C to 60°C range. The LSB increment is found by: 60°C • 41.4μV/°C = 2.42μV/ LSB ...
... proves even more stringent. The type K thermocouple puts out 41.4μV/°C over the 0°C to 60°C range. The LSB increment is found by: 60°C • 41.4μV/°C = 2.42μV/ LSB ...
Chapter 7 - Automation Direct
... aware of which may assist you in quickly correcting an I/O problem: • The output modules cannot detect shorted or open output points. If you suspect one or more points on a output module to be faulty, you should measure the voltage drop from the common to the suspect point. Remember, when using a D ...
... aware of which may assist you in quickly correcting an I/O problem: • The output modules cannot detect shorted or open output points. If you suspect one or more points on a output module to be faulty, you should measure the voltage drop from the common to the suspect point. Remember, when using a D ...
Evaluates: MAX8758 MAX8758 Evaluation Kit General Description Features
... The GON consists of two positive charge-pump stages to generate approximately +23V and can provide more than 20mA. The GOFF consists of a single negative charge-pump stage to generate approximately -8V and can provide more than 20mA. Loading the GON charge pump reduces the available output current o ...
... The GON consists of two positive charge-pump stages to generate approximately +23V and can provide more than 20mA. The GOFF consists of a single negative charge-pump stage to generate approximately -8V and can provide more than 20mA. Loading the GON charge pump reduces the available output current o ...
eet 3086 power transmission and distribution
... On the universal Fault Module INITIATE FAULT button………………………………………………….released position FAULT DURATION switch……………………………………………………….0.05 – 5 s Make sure that the current transformers are connected as shown in Figure 3 then set the switches of current transformers CT4, CT5, and CT6 on the current tra ...
... On the universal Fault Module INITIATE FAULT button………………………………………………….released position FAULT DURATION switch……………………………………………………….0.05 – 5 s Make sure that the current transformers are connected as shown in Figure 3 then set the switches of current transformers CT4, CT5, and CT6 on the current tra ...
Project code STCU/5388. Development, realisation and testing of the sample... phase shift transformer with thyristor control. Period of realisation 2011-2012....
... which will allow expanding further the theory and practice of creation and use of the highspeed phase-shift devices for management of modes of electropower systems. The laboratory sample of the high-speed phase-shift transformer by capacity near10 kVA with regulated (in a range from 0 to 60 ...
... which will allow expanding further the theory and practice of creation and use of the highspeed phase-shift devices for management of modes of electropower systems. The laboratory sample of the high-speed phase-shift transformer by capacity near10 kVA with regulated (in a range from 0 to 60 ...
SKY77185 数据资料DataSheet下载
... developed for Wideband Code Division Multiple Access (WCDMA) applications. This small and efficient module packs full 1920–1980 MHz bandwidth coverage into a single compact package. Because of high efficiencies attained throughout the entire power range, the SKY77185 delivers unsurpassed talk-time a ...
... developed for Wideband Code Division Multiple Access (WCDMA) applications. This small and efficient module packs full 1920–1980 MHz bandwidth coverage into a single compact package. Because of high efficiencies attained throughout the entire power range, the SKY77185 delivers unsurpassed talk-time a ...
BH12PB1WHFV
... the IC off to prevent runaway thermal operation. It is not designed to protect the IC or guarantee its operation. Do not continue to use the IC after operating this circuit or use the IC in an environment where the operation of this circuit is assumed. 5. Ground wiring patterns The power supply and ...
... the IC off to prevent runaway thermal operation. It is not designed to protect the IC or guarantee its operation. Do not continue to use the IC after operating this circuit or use the IC in an environment where the operation of this circuit is assumed. 5. Ground wiring patterns The power supply and ...
What is a Switch?
... – DC –Direct Current (minimum UL requirements) – Horsepower (for switches designed to control small motor loads) ...
... – DC –Direct Current (minimum UL requirements) – Horsepower (for switches designed to control small motor loads) ...
Classification of transformers according to turn ratio
... Classification of transformers according to their function: 1- Power transformer 2- Distribution transformer 3- Measuring transformers A)voltage transformer B) current transformer 4-Autotransformer- Tapped autotransformer ...
... Classification of transformers according to their function: 1- Power transformer 2- Distribution transformer 3- Measuring transformers A)voltage transformer B) current transformer 4-Autotransformer- Tapped autotransformer ...
shortwave power amplifier with gu84b
... In this amplifier a tetrode GU 84b is used in a grounded-cathode circuit (input into control grid). This amplifier achieves excellent linearity by the voltage stabilization of the control grid bias and the screen voltage. The power input is given to the control grid, using a broadband power transfor ...
... In this amplifier a tetrode GU 84b is used in a grounded-cathode circuit (input into control grid). This amplifier achieves excellent linearity by the voltage stabilization of the control grid bias and the screen voltage. The power input is given to the control grid, using a broadband power transfor ...
MAX685 Dual-Output (Positive and Negative), DC-DC Converter for CCD and LCD General Description
... General Description The MAX685 DC-DC converter provides low-noise dual outputs for powering CCD imaging devices and LCDs. This device uses a single inductor to provide independently regulated positive and negative outputs. Integrated power switches are included in a small 24Pin 4mm x 4mm Thin QFN pa ...
... General Description The MAX685 DC-DC converter provides low-noise dual outputs for powering CCD imaging devices and LCDs. This device uses a single inductor to provide independently regulated positive and negative outputs. Integrated power switches are included in a small 24Pin 4mm x 4mm Thin QFN pa ...
1002 eDIN DMX Repeater Spec
... One (1) DMX pass-thru port shall be provided. The pass-thru port shall be passive, i.e. directwired to the input and not repeated, such that failure of the Module shall not adversely affect a signal being passed through to another module or device. ...
... One (1) DMX pass-thru port shall be provided. The pass-thru port shall be passive, i.e. directwired to the input and not repeated, such that failure of the Module shall not adversely affect a signal being passed through to another module or device. ...
Aerre2 Single Control Panel Technical Manual
... MIN.LINE/VOLTAGE" or "MAX.LINE/VOLTAGE" alarms are exceeded for 1 minute the pumps will shut down. SCREEN 16: “SENSOR/10b/20b” Select 10 Bar When all values are set, switch the main switch “OFF”, wait for a few seconds to memorise the data then switch “ON” The memorised data will be retained for up ...
... MIN.LINE/VOLTAGE" or "MAX.LINE/VOLTAGE" alarms are exceeded for 1 minute the pumps will shut down. SCREEN 16: “SENSOR/10b/20b” Select 10 Bar When all values are set, switch the main switch “OFF”, wait for a few seconds to memorise the data then switch “ON” The memorised data will be retained for up ...
Solar micro-inverter
A solar micro-inverter, or simply microinverter, is a device used in photovoltaics that converts direct current (DC) generated by a single solar module to alternating current (AC). The output from several microinverters is combined and often fed to the electrical grid. Microinverters contrast with conventional string and central solar inverters, which are connected to multiple solar modules or panels of the PV system.Microinverters have several advantages over conventional inverters. The main advantage is that small amounts of shading, debris or snow lines on any one solar module, or even a complete module failure, do not disproportionately reduce the output of the entire array. Each microinverter harvests optimum power by performing maximum power point tracking for its connected module. Simplicity in system design, simplified stock management, and added safety are other factors introduced with the microinverter solution.The primary disadvantages of a microinverter include a higher initial equipment cost per peak watt than the equivalent power of a central inverter, and increased installation time since each inverter needs to be installed adjacent to a panel (usually on a roof). This also makes them harder to maintain and more costly to remove and replace (O&M). Some manufacturers have addressed these issues with panels with built-in microinverters.A type of technology similar to a microinverter is a power optimizer which also does panel-level maximum power point tracking, but does not convert to AC per module.