Delphi DNT04, Non-Isolated Point of Load
... from a world leader in power systems technology and manufacturing — Delta Electronics, Inc. The DNT04 series provides a programmable output voltage from 0.75V to 3.63V via external resistors. This product family is available in surface mount or SIP package and provides up to 3A of output current in ...
... from a world leader in power systems technology and manufacturing — Delta Electronics, Inc. The DNT04 series provides a programmable output voltage from 0.75V to 3.63V via external resistors. This product family is available in surface mount or SIP package and provides up to 3A of output current in ...
Selecting the correct IC for power-supply
... With the space constraints of our application, a linear charger is a good choice. The charging efficiency is not as much of a concern because the only time this device will operate is when the 12-V power adapter is available. However, when selecting the peak charge current of a battery deeply discha ...
... With the space constraints of our application, a linear charger is a good choice. The charging efficiency is not as much of a concern because the only time this device will operate is when the 12-V power adapter is available. However, when selecting the peak charge current of a battery deeply discha ...
ADM8828 数据手册DataSheet 下载
... The positive terminal of C1 is connected to GND via S3 during this phase and the negative terminal of C1 connects to VOUT via S4. The net result is voltage inversion at VOUT wrt GND. Charge on C1 is transferred to C2 during φ2. Capacitor C2 maintains this voltage during φ1. The charge transfer effic ...
... The positive terminal of C1 is connected to GND via S3 during this phase and the negative terminal of C1 connects to VOUT via S4. The net result is voltage inversion at VOUT wrt GND. Charge on C1 is transferred to C2 during φ2. Capacitor C2 maintains this voltage during φ1. The charge transfer effic ...
TQM776011 数据资料DataSheet下载
... package including a coupler and built-in voltage regulator makes it ideal for today’s extremely small data enabled phones. Its RF performance meets the stringent linearity requirements for multi-mode operation. The TQM776011 is designed on TriQuint’s GaAs BiHEMT technology with CuFlip ® assembly off ...
... package including a coupler and built-in voltage regulator makes it ideal for today’s extremely small data enabled phones. Its RF performance meets the stringent linearity requirements for multi-mode operation. The TQM776011 is designed on TriQuint’s GaAs BiHEMT technology with CuFlip ® assembly off ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331
... An intermediate circuit capacitor (DC-Link) as used in the intermediate circuit of converters of different kinds where it couples different electrical grids to one DC voltage level. Due to its high capacitance and its ability to supply power quickly the DC voltage intermediate circuit is supported, ...
... An intermediate circuit capacitor (DC-Link) as used in the intermediate circuit of converters of different kinds where it couples different electrical grids to one DC voltage level. Due to its high capacitance and its ability to supply power quickly the DC voltage intermediate circuit is supported, ...
Integrated Stereo/Mono Power Amplifier Stealth 60i Users' Manual (Beta)
... subwoofer is ideal for maximum power output. Although no damage will occur with any speaker impedance connected to any output, an 8 Ohm subwoofer will benefit from the re-configuration of each stereo output impedance to 16 Ohms (see below). The Stealth 60i inverts the phase of the input signal. If y ...
... subwoofer is ideal for maximum power output. Although no damage will occur with any speaker impedance connected to any output, an 8 Ohm subwoofer will benefit from the re-configuration of each stereo output impedance to 16 Ohms (see below). The Stealth 60i inverts the phase of the input signal. If y ...
An AC High Frequency Quasi Square Wave Bus Voltage for the Next
... (ZC) Resonant Converters, to supplement the Zero Voltage switching of AC/DC Bulk Converter. Another choice good choice is a secondary controlled synchronous rectifier PWM. Typical board or load regulators for the DC-DPS are shown in Figure 3, and a variety of choices are shown for the AC-DPS are sho ...
... (ZC) Resonant Converters, to supplement the Zero Voltage switching of AC/DC Bulk Converter. Another choice good choice is a secondary controlled synchronous rectifier PWM. Typical board or load regulators for the DC-DPS are shown in Figure 3, and a variety of choices are shown for the AC-DPS are sho ...
TD62083AFNG,TD62084AFNG - Toshiba America Electronic
... exceed its absolute maximum ratings, when the wiring is routed improperly or when an abnormal pulse noise occurs from the wiring or load, causing a large current to continuously flow and the breakdown can lead smoke or ignition. To minimize the effects of the flow of a large current in case of break ...
... exceed its absolute maximum ratings, when the wiring is routed improperly or when an abnormal pulse noise occurs from the wiring or load, causing a large current to continuously flow and the breakdown can lead smoke or ignition. To minimize the effects of the flow of a large current in case of break ...
Slide 1
... Possibility for use in freshman and sophomore level labs Used to test senior design projects that require DC voltage Assumptions/Limitations Powered by a 120V, 60Hz wall outlet +/- 1% ripple output voltage Function with +/- 5% of wall outlet voltage Output current not to exceed 1A on e ...
... Possibility for use in freshman and sophomore level labs Used to test senior design projects that require DC voltage Assumptions/Limitations Powered by a 120V, 60Hz wall outlet +/- 1% ripple output voltage Function with +/- 5% of wall outlet voltage Output current not to exceed 1A on e ...
Output Stages Class A, AB, and B Power Stages Laboratory
... Simulate the circuit shown in Figure 2.1. Change the power supply to +/- 35V. Set the bias voltages so that the quiescent currents through the power transistors is 200mA. Show that the quiescent currents through the power transistors is indeed 200mA. Set the input voltage so that the signal ...
... Simulate the circuit shown in Figure 2.1. Change the power supply to +/- 35V. Set the bias voltages so that the quiescent currents through the power transistors is 200mA. Show that the quiescent currents through the power transistors is indeed 200mA. Set the input voltage so that the signal ...
DN489 - High Efficiency, High Density 3
... processing systems, telecom systems, industrial equipment and DC power distribution systems. The LTC3829’s features include: • 4.5V to 38V input range and 0.6V to 5V output range ...
... processing systems, telecom systems, industrial equipment and DC power distribution systems. The LTC3829’s features include: • 4.5V to 38V input range and 0.6V to 5V output range ...
XR Series: 2 kW to 10 kW - Magna
... up for high reliability and industry leading 2U (3.5” height) rackmount power density, with output isolation for units rated up through 2000 Vdc. This product series utilizes Magna-Power Electronics signature current-fed power processing, delivering robust power conversion with a high power factor—g ...
... up for high reliability and industry leading 2U (3.5” height) rackmount power density, with output isolation for units rated up through 2000 Vdc. This product series utilizes Magna-Power Electronics signature current-fed power processing, delivering robust power conversion with a high power factor—g ...
NE2322092216
... distortion. The turn-on times are generated by the ANN and then converted to pulse widths through a simple logic circuit. The ANN significantly reduces the computational efforts of the modulation technique and makes the implementation of space vector modulation algorithm very fast without losing pre ...
... distortion. The turn-on times are generated by the ANN and then converted to pulse widths through a simple logic circuit. The ANN significantly reduces the computational efforts of the modulation technique and makes the implementation of space vector modulation algorithm very fast without losing pre ...
HEI Ignition Module For Use With Points
... equivalent to that of W. Therefore, the ignition-coil current is “on”. It takes about 5 seconds for C1 to discharge to 1.4 volts. G follows W through internal circuitry, so, after 5 seconds, the voltage on G is at 1.4 volts and the coil current is interrupted. This produces a single spark. If the po ...
... equivalent to that of W. Therefore, the ignition-coil current is “on”. It takes about 5 seconds for C1 to discharge to 1.4 volts. G follows W through internal circuitry, so, after 5 seconds, the voltage on G is at 1.4 volts and the coil current is interrupted. This produces a single spark. If the po ...
FWC-FSLC-EZM1, EZM2_A626.05_DATA.pub
... The Napco FWC-FSLC-EZM1 Fast Response Contact Module and FWC-FSLC-EZM2 Dual Input Monitor Module are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact devices. The interrupt driven communications protocol combines maximum comm ...
... The Napco FWC-FSLC-EZM1 Fast Response Contact Module and FWC-FSLC-EZM2 Dual Input Monitor Module are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact devices. The interrupt driven communications protocol combines maximum comm ...
RF5122 3V TO 3.6V, 2.4GHz TO 2.5GHz LINEAR POWER AMPLIFIER Features
... available supply voltage and current are limited. This amplifier will operate to (and below) the lowest expected voltage made available by a typical PCMCIA slot in a laptop PC, and will maintain required linearity at decreased supply voltages. The RF5122 requires only a single positive supply of 3.3 ...
... available supply voltage and current are limited. This amplifier will operate to (and below) the lowest expected voltage made available by a typical PCMCIA slot in a laptop PC, and will maintain required linearity at decreased supply voltages. The RF5122 requires only a single positive supply of 3.3 ...
28 VOLT INPUT - Crane Interpoint
... The HR120 converters are switching regulators which use a quasisquare wave, single ended forward converter design with a nominal switching frequency of 600 kHz. Isolation between input and output circuits is provided with a transformer in the forward power loop and a temperature insensitive optical ...
... The HR120 converters are switching regulators which use a quasisquare wave, single ended forward converter design with a nominal switching frequency of 600 kHz. Isolation between input and output circuits is provided with a transformer in the forward power loop and a temperature insensitive optical ...
XP95 Low Power Relay Base
... Supply voltage in series with 4.4kΩ resistor Operating temperature –20° C to +70° C Humidity (no condensation) 0% –95% RH ...
... Supply voltage in series with 4.4kΩ resistor Operating temperature –20° C to +70° C Humidity (no condensation) 0% –95% RH ...
Installation Guide — GEPS24-100U
... accordance with National Electric Code (NEC) Article 600. • Follow all National Electric Codes (NEC) and local codes. • These products are only suitable for connection to a circuit from a Class 2 power source. These products have not been evaluated for use when connected to a power sourc ...
... accordance with National Electric Code (NEC) Article 600. • Follow all National Electric Codes (NEC) and local codes. • These products are only suitable for connection to a circuit from a Class 2 power source. These products have not been evaluated for use when connected to a power sourc ...
Solar micro-inverter
A solar micro-inverter, or simply microinverter, is a device used in photovoltaics that converts direct current (DC) generated by a single solar module to alternating current (AC). The output from several microinverters is combined and often fed to the electrical grid. Microinverters contrast with conventional string and central solar inverters, which are connected to multiple solar modules or panels of the PV system.Microinverters have several advantages over conventional inverters. The main advantage is that small amounts of shading, debris or snow lines on any one solar module, or even a complete module failure, do not disproportionately reduce the output of the entire array. Each microinverter harvests optimum power by performing maximum power point tracking for its connected module. Simplicity in system design, simplified stock management, and added safety are other factors introduced with the microinverter solution.The primary disadvantages of a microinverter include a higher initial equipment cost per peak watt than the equivalent power of a central inverter, and increased installation time since each inverter needs to be installed adjacent to a panel (usually on a roof). This also makes them harder to maintain and more costly to remove and replace (O&M). Some manufacturers have addressed these issues with panels with built-in microinverters.A type of technology similar to a microinverter is a power optimizer which also does panel-level maximum power point tracking, but does not convert to AC per module.