• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Aalborg Universitet Loss comparison of different nine-switch and twelve-switch energy conversion systems
Aalborg Universitet Loss comparison of different nine-switch and twelve-switch energy conversion systems

... converter thus saves two switches as compared to the standard six-switch converter. The same reduction of switches can be performed when two six-switch bridges are connected backto-back to form an ac-dc-ac converter. An example, which saves two switches, is discussed in [4], where the five-leg conve ...
VHC/VHCT CMOS families - Digital Design Principles and Practices
VHC/VHCT CMOS families - Digital Design Principles and Practices

L24093097
L24093097

... design of minimum power and high-performance SRAM as they are significant components in together handheld devices and high performance processors [1]. Dynamic power has been a main source of power dissipation. The static power dissipation is flattering a large part of the total power dissipation. In ...
User Manual and Installation Guide
User Manual and Installation Guide

... Experienced users of the Solar Power System will find this section provides a quickstart guide in assembling and maintaining the System while those new to the product will find detailed instructions for the installation, operation, and maintaining of the system. ...
LT1580(-2.5) - Linear Technology
LT1580(-2.5) - Linear Technology

... regulator. Both the fixed and adjustable devices have remote SENSE pins, permitting very accurate regulation of output voltage at the load, where it counts, rather than at the regulator. As a result the typical load regulation over an output current range of 100mA to 7A with a 2.5V output is typical ...
Not Recommended for New Designs
Not Recommended for New Designs

... Conservative design dictates that the diode average current rating be 2 times the desired output current. If operation with extended short-circuit or overload time is expected, then the diode current rating must exceed the current limit (6.5A = MAX724, 2.6A = MAX726), and heat sinking may be necessa ...
BD5423AEFS
BD5423AEFS

... device. A result of destruction, whether it is short mode or open mode, is not predictable. Therefore, provide a physical safety measure such as fuse, against a special mode that may violate conditions of absolute maximum ratings. 2. About power supply line As return of current regenerated by back E ...
RA60H3847M1 数据资料DataSheet下载
RA60H3847M1 数据资料DataSheet下载

Measuring Power regulated by Zero Crossing SCR
Measuring Power regulated by Zero Crossing SCR

... The typical watt transducer is designed to filter the AC ripple that is the result of the instantaneous multiplication of AC voltage and AC current. For a single-phase load powered from a 60 hertz source the ripple will be at 120 hertz and have a minimum peak to peak value that is twice the actual p ...
125-µA Standby, High-Efficiency Power Supply
125-µA Standby, High-Efficiency Power Supply

... terminal. The UL773A does allow it with certain restrictions and one of the important requirements is that the current flowing through the ground should be limited to 0.5 mA. This is to ensure that the ground current does not exceed the trip limit of the earth leakage circuit breaker, which may be t ...
ACTIVE POWER FILTERING TECHNIQUES FOR HARMONIC
ACTIVE POWER FILTERING TECHNIQUES FOR HARMONIC

... Passive filter ratings must be co-ordinated with reactive power requirements of the loads and it is often difficult to design the filters to avoid leading power factor operation for some load conditions. Active filters have the advantage of being able to compensate for harmonics without fundamental ...
DCR01 Series: Miniature, 1W Isolated
DCR01 Series: Miniature, 1W Isolated

... (minimum) for the 5V input devices and a 0.47µF capacitor for the 12V and 24V devices, placed close to the IC supply input pins, the effects on the power supply can be minimized. The high switching frequency of 400kHz allows relatively small values of capacitors to be used for filtering the rectifie ...
Healthcare Isolation Power Systems
Healthcare Isolation Power Systems

Introduction
Introduction

... The open collector output can interface to light duty devices and the relay contacts offer heavy duty load switching. Set-up and installation are simplified through front panel entry of configuration parameters and a unique “no tools required” panel mounting bracket. The V454500 family of preset cou ...
doc
doc

... The control circuitry shall automatically synchronize and phase lock the inverter output to the bypass AC power source as long as the bypass source is within the synchronization range. The synchronization range shall be adjustable from ±1/8 Hz to ±5 Hz, selectable in maximum increments of 0.1 Hz. If ...
Leakage Power Reduction for Logic Circuits Using Variable Body
Leakage Power Reduction for Logic Circuits Using Variable Body

... maintain high switching speed. Sleep transistors are turned off when the device is in idle state, which dramatically reduces the leakage power in standby mode. During active mode the device works normally. FORCED STACK: Transistor stacking is the technique where the leakage power is suppressed great ...
DS1813 - Maxim Integrated
DS1813 - Maxim Integrated

... Figure 4. Timing Diagram: Power-Up ...
FPM2750QFN LOW-NOISE HIGH-LINEARITY BALANCED AMPLIFIER MODULE Features
FPM2750QFN LOW-NOISE HIGH-LINEARITY BALANCED AMPLIFIER MODULE Features

... Information on the mounting of QFN-style packages for optimum thermal performance is available on request. ...
AN9506: A 50W, 500kHz, Full-Bridge, Phase-Shift, ZVS
AN9506: A 50W, 500kHz, Full-Bridge, Phase-Shift, ZVS

... designers to easily move their designs upwards in frequency. The topology offers additional advantages like zerovoltage-switching at a constant switching frequency, which substantially reduces switching losses. This can be significant enough to eliminate heatsinking of power MOSFETS and/or enabling ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Fig 1 waveform representing voltage sag,swell, impulse voltage A custom power specification may include provision for (i) no power interruption (ii) Tight Voltage regulation including short duration sags or swells (iii) Low harmonic Voltages and (iv) Acceptance of fluctuating and non linear loads wi ...
Low-Complexity MPPT Technique Exploiting the PV Module MPP
Low-Complexity MPPT Technique Exploiting the PV Module MPP

... VOC . As it will be further demonstrated, the proposed method presents better results when compared to other offline methods of comparably low complexity. This paper is organized as follows. In the first part, Section II, the mathematical analysis of a PV module electrical model is presented, which ...
Atmel LED Driver-MSL1060
Atmel LED Driver-MSL1060

... General Description The Atmel LED DriverMSL1060 is an LED driver with integrated boost regulator capable of driving 6 LED strings at 30mA up to 48V for lighting applications to 8W. In a typical backlighting system it can drive up to 72 white LEDs. ...
DC bus voltage control for a distributed power system
DC bus voltage control for a distributed power system

... (VSCs). The main advantage gained by using transistor based VSCs compared to thyristor based CSCs is that the harmonic content of the ac side current is reduced to a large extent. For transistor-based VSCs the switching frequency can be selected arbitrary, which means that the ac line current can be ...
Powerware 9305 7.5
Powerware 9305 7.5

... data loss in unprotected systems are caused by bad power? All those network crashes, mysterious error messages, damaged files and other anomalies bog your system down and take hours to be fixed. ...
CD54ACT04, CD74ACT04  HEX INVERTERS D
CD54ACT04, CD74ACT04 HEX INVERTERS D

... Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous output current, IO ...
< 1 ... 104 105 106 107 108 109 110 111 112 ... 384 >

Solar micro-inverter



A solar micro-inverter, or simply microinverter, is a device used in photovoltaics that converts direct current (DC) generated by a single solar module to alternating current (AC). The output from several microinverters is combined and often fed to the electrical grid. Microinverters contrast with conventional string and central solar inverters, which are connected to multiple solar modules or panels of the PV system.Microinverters have several advantages over conventional inverters. The main advantage is that small amounts of shading, debris or snow lines on any one solar module, or even a complete module failure, do not disproportionately reduce the output of the entire array. Each microinverter harvests optimum power by performing maximum power point tracking for its connected module. Simplicity in system design, simplified stock management, and added safety are other factors introduced with the microinverter solution.The primary disadvantages of a microinverter include a higher initial equipment cost per peak watt than the equivalent power of a central inverter, and increased installation time since each inverter needs to be installed adjacent to a panel (usually on a roof). This also makes them harder to maintain and more costly to remove and replace (O&M). Some manufacturers have addressed these issues with panels with built-in microinverters.A type of technology similar to a microinverter is a power optimizer which also does panel-level maximum power point tracking, but does not convert to AC per module.