• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
UL 508 A Short Circuit Current Rating
UL 508 A Short Circuit Current Rating

... the assembly. For panel assemblies containing only Control Circuits, SCCR rating markings are not required for the assembly. An exception to Article 409.110(3) was added for clarification in the 2008 NEC®. Of course, the final decision as to whether a panel assembly exclusively contains Control Circ ...
Validation of the Measurement Characteristics in an Instrument for
Validation of the Measurement Characteristics in an Instrument for

... The description of effects related to the deviations of the characteristics of the measurement channel (i.e., lost performance or improper calibration) of various devices, causing the deterioration of the operation performance, can be found, e.g., in [19,20]. The vital issue for millions of customer ...
AN-9005 - Fairchild Semiconductor
AN-9005 - Fairchild Semiconductor

... are no excessive minority carriers. However, there is displacement current, which is negligible, from parasitic junction capacitances. Therefore, SiC Schottky diode and Si diodes are used for clamped diodes since this drastic difference of reverse-recovery characteristics in transient behavior allow ...
Harmonic mitigation Solution Handbook
Harmonic mitigation Solution Handbook

Chapter 3: Resistive Network Analysis – Instructor Notes
Chapter 3: Resistive Network Analysis – Instructor Notes

... analogies between electrical and thermal circuit elements. These analogies are to be encountered again in Chapter 5. A brief discussion of the principle of superposition precedes the discussion of Thèvenin and Norton equivalent circuits. Again, the presentation is rich in examples and drill exercise ...
installation, start-up and adjustment manual
installation, start-up and adjustment manual

... Air-cooled models are factory tested and adjusted using natural gas as a fuel. You may, however, use liquid propane (LP) gas as a fuel, but it would require you to make minor adjustments at the gaseous fuel load block. See “Adjusting the Load Block.” With LP gas, use only the vapor withdrawal type s ...
RF2817 GPS LOW NOISE AMPLIFIER WITH INTEGRATED INPUT/OUTPUT SAW FILTERS Features
RF2817 GPS LOW NOISE AMPLIFIER WITH INTEGRATED INPUT/OUTPUT SAW FILTERS Features

Resistors Resistors are the most commonly used component in
Resistors Resistors are the most commonly used component in

Module - InnoVictor
Module - InnoVictor

... powered and clocked. However, the software has control of clocks and bias currents, it removes the clocks and bias currents from digital and RF/analog circuits when these circuits are not in use. Hibernate In Hibernate state, only essential areas are powered, RTC, IO, RAMs. Current levels are typica ...
An End Fed Half Wave Length Antenna is a variation of the much
An End Fed Half Wave Length Antenna is a variation of the much

... not energized. I had taken measures to prevent as much coupling as I could to the shield of the coax (no direct connection, fig. 12, and ran the coax 90 degrees to the antenna). There may have been some stray capacitance but there was not enough to "complete the circuit". It should be noted that inc ...
S280-75-2
S280-75-2

... in Figure 6. Line current conditions are continuously monitored by the three bushing-type current transformers in the recloser. output from these transformers is fed to the trip network in the control, which includes: the minimum-trip resistors, isolation transformers, and rectifier circuits. If cur ...
File - ELECTRICAL ENGINEERING DEPT, DCE
File - ELECTRICAL ENGINEERING DEPT, DCE

Chapter 4-Webster The Origin of Biopotentials
Chapter 4-Webster The Origin of Biopotentials

... another electrode consisting of a piece of Ag coated with a layer of AgCl and an attached wire are placed in a 1 M ZnCl2 solution (activities of Zn2+ and Cl- are approximately unity) to form an electrochemical cell that is maintained at a temperature of 25 oC. a. What chemical reactions might you ex ...
Picture - SolarToday
Picture - SolarToday

... ·The installation,service, recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations. ·Any unauthorized actions including modification of product functionality of any form may cause lethal hazard to the opera ...
MS-28 Handbook - Maintenance of Electrical Switchgear
MS-28 Handbook - Maintenance of Electrical Switchgear

... Norman, OK 73070-1600 ...
electrical installation standards
electrical installation standards

... The wiring must be performed using flexible T wires with end fittings arranged in ducts made from an insulating material with a cover (wiring ducts). It must be rigidly attached at multiple attachment points. No more than two conductors may be connected at each attachment point. In all cases, it mus ...
AAT4684 数据资料DataSheet下载
AAT4684 数据资料DataSheet下载

... On initial power-up, if VIN < UVLO or if VOVP > VOVP_TH (1.1V), the PMOS is held off. If UVLO < VIN, VOVP < VOVP_TH, and EN is low, the device enters startup after a 10ms internal delay. ...
Resistors - Bieap.gov.in
Resistors - Bieap.gov.in

... (a) To establish proper values of circuit voltages due to IR drops (b) To limit current and (c) To provide load. ...
NPCC Glossary of Terms - Northeast Power Coordinating Council
NPCC Glossary of Terms - Northeast Power Coordinating Council

... Facilities required to establish a basic minimum power system following a system blackout. These facilities are essential to the restoration plan of the Control Area and include generating stations having blackstart units and other selected generating stations, transmission elements which are part o ...
IF 1664 Revision 2
IF 1664 Revision 2

... Perform visual, electrical, and mechanical inspections on a regular basis. The environment and frequency of use should determine this. However, it is recommended that checks be made at least once a year. We recommend an Electrical Preventive Maintenance Program as described in the National Fire Prot ...
An Optimal Power Supply And Body Bias Voltage
An Optimal Power Supply And Body Bias Voltage

... the operational frequency is increased linearly to VDD From Figure 6 (a) and (b), it appears that the maximum frequency is not improved when the forward bias is given to only a part, since another part bottlenecks the whole micro-controller. In order to achieve a certain frequency, both core and mem ...
Guidelines for PS Clause EMS02 (revised in March 2017)
Guidelines for PS Clause EMS02 (revised in March 2017)

... within  the  working  area  inside  the  ceiling  void,  such  as:  casing  of  electrical  equipment  being  energized  due  to  internal  fault,  electrical  hazard  arising  from  improper  installation  of  electrical  equipment,  exposed  conductive  ends  of  uncovered cables.  (b) For  electr ...
lecture1423723756
lecture1423723756

... distribution is so great that the proper precautions must be taken to ensure that the equipment not only operates as nearly as possible to peak efficiency, but also must be protected from accidents The normal path of the electric current is from the power source through copper (or aluminium) conduct ...
Auto-Electric Basic Technology - Part 2
Auto-Electric Basic Technology - Part 2

... it (air or non−magnetic material) they run from the north to the South Pole. Inside the magnet, they run from the South Pole to the North Pole. The field lines are therefore closed (continuous). If a magnet gets divided or broken, in every part will be obtained a north and a South Pole. ...
CHAPTER 2: Diode Applications (Aplikasi Diod)
CHAPTER 2: Diode Applications (Aplikasi Diod)

... Power supply is a group of circuits that convert the standard ac voltage (120 V, 60 Hz) provided by the wall outlet to constant dc voltage. The voltage produced is used to power all types of electronic circuits including: Consumer electronics (ex: radio, television, DVD, etc.) Computers Industrial c ...
< 1 ... 63 64 65 66 67 68 69 70 71 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report