• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Logic: From Greeks to philosophers to circuits. COS 116: 3/15/2005 Adam Finkelstein
Logic: From Greeks to philosophers to circuits. COS 116: 3/15/2005 Adam Finkelstein

... Discussion for next time: What exactly does Clarke’s “proof” prove? How convincing is such a proof to you? Also: Do Google search for “Proof of God’s Existence.” ...
Regulated Power Supply.doc
Regulated Power Supply.doc

... The LM78XX series is available in an aluminum TO-3 package which will allow over 1.0A load current if adequate . Heat sinking is provided. Current limiting is included to limit the peak output current to a safe value. Safe area protection for the output transistor is provided to limit internal power ...
Word Version - DCC - LIGO Document Control Center Portal
Word Version - DCC - LIGO Document Control Center Portal

... of contact closure, could apply a rapid voltage step to a circuit. This, in turn provides the means to force excessive current through capacitors. Therefore, it is would be best to locate the switch upstream of a local power regulator board, and let the regulator take the hit, rather than jamming a ...
Lab 1 - UniMAP Portal
Lab 1 - UniMAP Portal

press release
press release

... volume attenuators, are identical to those found in the No32. Although it features a single-chassis design, the No320S achieves similar separation of audio circuit, control, and power supply sections as the dual-chassis No32. Inside the No320S, these sections are separated by physical layout as well ...
UNIT – II Magnetic Circuits - jawaharlal nehru technological university
UNIT – II Magnetic Circuits - jawaharlal nehru technological university

... This course introduces the basic concepts of circuit analysis which is the foundation for all subjects of the Electrical Engineering discipline. The emphasis of this course is laid on the basic analysis of circuits which includes Single phase circuits, magnetic circuits, theorems. UNIT – I Introduct ...
ce-b36 metal clad - Casagrande Elettrocostruzioni SpA
ce-b36 metal clad - Casagrande Elettrocostruzioni SpA

... instrument compartment, which is usually placed above the circuit-breaker compartment ...
無投影片標題
無投影片標題

... to give an accurate value of prospective short-circuit current as its magnitude varies with changes in infeed cable network. The max. prospective short-circuit current is declared to be 40kA at low voltage side for the following supply arrangements: i) Feeding from a transformer provided and install ...
SWER - NZ & Aust Experience
SWER - NZ & Aust Experience

... Earthing Requirements ...
Radiation Detector High Voltage Shock Potential
Radiation Detector High Voltage Shock Potential

... INITIAL QUESTION: Knowing that most common radiation detectors (Geiger-Mueller, scintillation, and proportional detectors) require a high voltage (HV) supply to operate correctly, is this HV dangerous for the operator? BACKGROUND: Most common radiation electronics have a coaxial cable connection tha ...
Overview The function of the physical layer is to transmit data by
Overview The function of the physical layer is to transmit data by

CIRCUIT FUNCTION AND BENEFITS CIRCUIT DESCRIPTION
CIRCUIT FUNCTION AND BENEFITS CIRCUIT DESCRIPTION

... The current source circuit is shown in Figure 1. Reference voltage, VREF, is applied to the noninverting input of the AD8276. This voltage controls the amount of output current, IO. The inverting input of the AD8276 is connected directly to ground. There are four laser-trimmed, 40 kΩ resistors insid ...
Short-Circuit Protection for Power Inverters
Short-Circuit Protection for Power Inverters

... gate driving. High current capability (2A source, 3A sink) and 20Vcapable output stages allow this device to control a wide range of power devices. Each output stage has three separate pins for gate control to allow flexible customization of the IGBT gate charge. The two separate channels allow safe ...
sleuth - I-Gard
sleuth - I-Gard

... Upon energizing the control panel the “SYSTEM NORMAL” green light turns on signifying that no ground faults are on the system and the I-Gard Sleuth is receiving control voltage. Verify the I-Gard Sleuth condition by pushing the “TEST” button TWICE. This causes the DGF-CT-A to trip. The green light t ...
tender specifications
tender specifications

... This module represents basic concepts of the Electric Energy high-voltage three-phase transmission lines operation. It simulates a value modifying concentrated parameter line that allows different configurations and consists on three conductor line (R, S, T) and a Neutral or return line (N). Each of ...
Safety First!
Safety First!

Installation Guide Here
Installation Guide Here

... Install the PG-3 in the flasher socket and connect the PG-3 electronics ground wire to a clean body ground, then start the engine. Place the turn lever to a direction and the PG-3 will begin flashing. (Be sure battery voltage levels are at least 11.6 volts or higher when signal lights are ON.) If no ...
2033D Facility Planning Data Sheet
2033D Facility Planning Data Sheet

RhinoStat Maintenance-Specifications
RhinoStat Maintenance-Specifications

... for use in areas where standing is required and ESD, safety and comfort are a must. They can be used as floor runners or can be installed to cover an entire workstation or department. The floor pieces are an interlocking design, each piece having (5) locking lugs that effectively lock to one another ...
5. Radial System Protection
5. Radial System Protection

as1 series compact case
as1 series compact case

FA01 ELEC-CHAR
FA01 ELEC-CHAR

... leakages, etc...) including problems that might not be obvious from a series of single point measurements- CT =continuous ...
Generator and Transformer
Generator and Transformer

Node Voltage with Thevenin Equivalent
Node Voltage with Thevenin Equivalent

... associated with each data point for Channel 1 and Channel 2: Look at the numbers next to CH1: and CH2: above the GND row. In this case, 1V is equivalent to 32. This means that that the value of the points in the columns CH1 and CH2 should be divided by 32 and then multiplied by 1V to finally obtain ...
RFVC9751 数据资料DataSheet下载
RFVC9751 数据资料DataSheet下载

... Package: MCM, 20-Pin, 6mmx6mm ...
< 1 ... 482 483 484 485 486 487 488 489 490 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report